文献速递乳腺乳腺X线USMR

乳头溢液的影像学评估:乳腺X线摄影、超声、乳管造影与MRI

Nipple Discharge Imaging Evaluation with Mammography, Ultrasound, Galactography, and MRI.
PubMed 文献 · Acad Radiol · 2022-06-25

单中心回顾性研究纳入320例连续乳头溢液患者,评估影像学对恶性肿瘤、非典型高危病变及导管内乳头状瘤的诊断效能。乳腺X线摄影联合超声对恶性肿瘤敏感度93%、阴性预测值98%;增强MRI敏感度和阴性预测值均达100%,可检出前者漏诊的恶性肿瘤并可能避免手术切除导管。

要点

  • 乳腺X线摄影联合超声对乳头溢液相关乳腺癌的敏感度为93%,阴性预测值为98%。
  • 增强MRI对恶性肿瘤的敏感度和阴性预测值均为100%,可检出X线摄影和超声未发现的恶性肿瘤。
  • 血性溢液与恶性肿瘤相关(比值比6.5,P<0.0001),年龄较大亦与恶性肿瘤相关(P<0.001)。

核心结论

  • 乳腺X线摄影联合超声可检出93%的乳头溢液相关乳腺癌,阴性预测值98%;增强MRI的价值在于检出X线摄影和超声未发现的剩余恶性肿瘤,并可能避免手术切除导管。

研究设计与样本

  • 单中心、经IRB批准的回顾性研究,纳入320例连续乳头溢液患者,回顾影像学与病理学资料以确定恶性肿瘤、非典型高危病变和导管内乳头状瘤的诊断率。

关键影像表现/征象

  • 320例中病理或随访证实乳腺癌40例(40/320,12.5%)、非典型高危病变14例(14/320,4.4%)、导管内乳头状瘤71例(71/320,22.2%)。
  • 其他良性病变48例(48/320,15.0%),性质未知但良性者147例(147/320,45.9%)。
  • 恶性肿瘤病例中仅少数表现为生理性溢液特征:非自发性4/40(10.0%),非血性且非清亮4/40(10.0%),双侧3/40(7.5%)。
  • 恶性肿瘤与年龄较大相关(P<0.001),与血性溢液相关(比值比6.5,P<0.0001)。

诊断标准与关键数值

  • 乳腺X线摄影联合超声对恶性肿瘤的敏感度为93%,阴性预测值为98%。
  • 增强MRI对恶性肿瘤的敏感度为100%,阴性预测值为100%。
  • 恶性队列中仅行3例乳管造影,其中1例对诊断评估有微小贡献,该例乳管造影发现有助于判定影像-病理不一致,促使建议手术切除并最终确诊恶性。

临床应用与阅片要点

  • 乳腺X线摄影联合超声可作为乳头溢液评估的基础影像组合,其对恶性肿瘤的阴性预测值为98%。
  • 增强MRI可检出乳腺X线摄影和超声未发现的恶性肿瘤,并可能避免手术切除导管。
  • 血性溢液者恶性肿瘤风险升高(比值比6.5),年龄较大亦与恶性相关(P<0.001)。
  • 恶性肿瘤病例中部分表现为非自发性、非血性或非清亮、双侧溢液,生理性溢液特征不能排除恶性。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

RATIONALE AND OBJECTIVE: To determine the diagnostic yield of various imaging tests used to evaluate nipple discharge.

MATERIALS AND METHODS: A single institution, IRB-approved, retrospective study was performed of 320 consecutive patients presenting with nipple discharge. Imaging and pathology were reviewed to determine the yield for malignancy, atypical high-risk lesions (HRLs), and intraductal papillomas (IDPs).

RESULTS: Of the 320 patients, pathology or follow up confirmed 40 breast malignancies (40/320, 12.5%),14 atypical HRLs (14/320, 4.4%), 71 IDPs (71/320, 22.2%), 48 other benign pathologies (48/320,15.0%), and 147 unknown but benign cases (147/320, 45.9%). Physiologic discharge characteristics were observed in a minority of malignant cases: nonspontaneous (4/40, 10.0%); neither bloody nor clear (4/40, 10.0%); bilateral (3/40, 7.5%). Malignancy was associated with older age (p < 0.001) and bloody discharge (odds ratio 6.5, p < 0.0001). The combination of digital mammography and ultrasound had a 93% sensitivity and a 98% NPV, while contrast enhanced MRI (CE-MRI) had a 100% sensitivity and a 100% NPV for malignancy. Only three galactography examinations were performed among the malignant cohort, with minimal contribution (1 of 3) to the diagnostic evaluation. In this case, galactography findings helped determine imaging-pathology discordance, prompting a recommendation for surgical excision and subsequently a malignant diagnosis.

CONCLUSION: The combination of mammography and ultrasonography detected 93% of breast malignancies associated with nipple discharge and had a 98% NPV for malignancy. The value of CE-MRI is its ability to detect the remaining malignancies, not detected on mammography or ultrasound, and its ability to obviate the need for surgical duct excision.

来源:Acad Radiol,查看原文。版权归原作者所有。

引用

  1. Chung, Bevers, Legha, et al. Nipple Discharge Imaging Evaluation with Mammography, Ultrasound, Galactography, and MRI. Acad Radiol. 2022. PMID: 35760711. doi:10.1016/j.acra.2022.05.013

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。