文献速递心血管CTDSA

基于卷积神经网络的冠状动脉CT血管成像自动冠状动脉疾病报告与数据系统(CAD-RADS)的临床评估

Clinical Evaluation of the Automatic Coronary Artery Disease Reporting and Data System (CAD-RADS) in Coronary Computed Tomography Angiography Using Convolutional Neural Networks.
PubMed 文献 · Acad Radiol · 2022-06-23

本研究在346例接受冠状动脉CT血管成像(CCTA)的患者中,回顾性比较了基于深度学习的自动分割后处理系统与人工阅片者对CAD-RADS分级的一致性,并以有创冠状动脉造影为参考评估深度学习模型诊断冠心病的效能;结果显示模型与阅片者分级无显著差异、一致性Kappa为0.775~0.802,且将报告时间从14.97±1.80分钟缩短至5.02±0.8分钟。

要点

  • 深度学习模型诊断冠心病的敏感度79.02%、特异度86.52%、准确率82.08%,阳性预测值89.50%、阴性预测值73.94%。
  • 模型与阅片者的CAD-RADS分级一致性Kappa分别为0.775、0.802、0.796,无显著差异。
  • 自动系统将报告时间从14.97±1.80分钟缩短至5.02±0.8分钟(p<0.001)。

核心结论

  • 基于深度学习的CAD-RADS标准化报告在CCTA中可准确、快速地评估疑似冠心病患者,且与放射科医师分级具有良好一致性。

研究设计与样本

  • 回顾性验证队列研究,纳入346例接受冠状动脉CT血管成像(CCTA)的患者,比较基于深度学习的自动分割后处理系统与人工阅片者的CAD-RADS分级,并以有创冠状动脉造影为参考标准评估诊断效能。

诊断标准与关键数值

  • 深度学习模型诊断冠心病的敏感度79.02%、特异度86.52%、阳性预测值89.50%、阴性预测值73.94%、准确率82.08%。
  • 模型与阅片者CAD-RADS分级一致性Kappa为0.775(95%CI 0.728-0.823)、0.802(95%CI 0.756-0.847)、0.796(95%CI 0.750-0.843),均p<0.001。
  • 自动系统报告时间5.02±0.8分钟,人工后处理报告时间14.97±1.80分钟(p<0.001)。

临床应用与阅片要点

  • 该系统可用于CCTA的CAD-RADS自动后处理与标准化报告,与放射科医师分级一致性良好。
  • 使用自动系统可缩短报告时间,从14.97±1.80分钟降至5.02±0.8分钟。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

RATIONALE AND OBJECTIVES: The coronary artery disease reporting and data system (CAD-RADS™) was recently introduced to standardise reporting. We aimed to evaluate the utility of an automatic postprocessing and reporting system based on CAD-RADS™ in suspected coronary artery disease (CAD) patients.

MATERIALS AND METHODS: Clinical evaluation was performed in 346 patients who underwent coronary computed tomography angiography (CCTA). We compared deep learning (DL)-based CCTA with human readers for evaluation of CAD-RADS™ with commercially-available automated segmentation and manual postprocessing in a retrospective validation cohort.

RESULTS: Compared with invasive coronary angiography, the sensitivity, specificity, positive predictive value, negative predictive value, and accuracy of the DL model for diagnosis of CAD were 79.02%, 86.52%, 89.50%, 73.94%, and 82.08%, respectively. There was no significant difference between the DL-based and the reader-based CAD-RADS™ grading of CCTA results. Consistency testing showed that the Kappa value between the model and the readers was 0.775 (95% confidence interval [CI]: 0.728-0.823, p < 0.001), 0.802 (95% CI: 0.756-0.847, p < 0.001), and 0.796 (95% CI: 0.750-0.843, p < 0.001), respectively. This system reduces the time taken from 14.97 ± 1.80 min to 5.02 ± 0.8 min (p < 0.001).

CONCLUSION: The standardised reporting of DL-based CAD-RADS™ in CCTA can accurately and rapidly evaluate suspected CAD patients, and has good consistency with grading by radiologists.

来源:Acad Radiol,查看原文。版权归原作者所有。

引用

  1. Huang, Xiao, Wang, et al. Clinical Evaluation of the Automatic Coronary Artery Disease Reporting and Data System (CAD-RADS) in Coronary Computed Tomography Angiography Using Convolutional Neural Networks. Acad Radiol. 2022. PMID: 35753936. doi:10.1016/j.acra.2022.05.015

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。