肩关节3T磁共振成像中BLADE与直线K空间填充技术的图像质量改善与运动伪影降解减少比较

Image quality improvement and motion degradation reduction in shoulder MR imaging: comparison of BLADE and rectilinear techniques at 3-Tesla scanning.
PubMed 文献 · Skeletal Radiol · 2022-06-25

本研究在4个月内连续纳入57例患者(22男,35女;平均年龄48.5岁,范围23-64岁),比较传统中间加权自旋回波与BLADE序列在肩关节3T磁共振中的图像质量。三位肌骨放射科医师采用Likert量表评估运动降解、鬼影/相位错位伪影、星芒/径向编码伪影、脂肪抑制质量和整体诊断质量,并分析SNR和CNR。结果显示BLADE序列鬼影和相位伪影更低,但条纹伪影更高(p<0.001);脂肪抑制、肌腱和盂唇表现、整体SNR和CNR两序列相当(p>0.05)。结论认为BLADE可减少运动降解并改善整体诊断图像质量。

要点

  • BLADE序列鬼影和相位伪影低于传统序列,但条纹伪影更高(p<0.001)。
  • 两序列脂肪抑制质量、肌腱和盂唇表现、整体SNR和CNR相当(p>0.05)。
  • 对怀疑运动伪影的患者应用BLADE可减少因幽闭恐惧症或运动担忧而重复成像的频率。

核心结论

  • 加入BLADE可减少运动降解并改善整体诊断图像质量,对怀疑运动伪影的患者应用BLADE可减少重复成像频率,并可能通过减少总成像时间和召回降低患者和医疗系统成本负担。

研究设计与样本

  • 在4个月期间连续扫描57例患者(22男,35女;平均年龄48.5岁,范围23-64岁),使用传统中间加权自旋回波和BLADE序列进行肩关节3T磁共振成像;由三位肌骨 fellowship 培训的放射科医师(各超过5年经验)进行定性评估,采用Likert量表评估五个类别,并通过手动绘制感兴趣区分析SNR和CNR。

关键影像表现/征象

  • BLADE序列鬼影和相位伪影更低(p<0.001)。
  • BLADE序列条纹伪影更高(p<0.001)。
  • 两序列脂肪抑制质量、肌腱和盂唇表现相当(p>0.05)。
  • 两序列整体SNR和CNR相当(p>0.05)。

诊断标准与关键数值

  • 采用Likert量表定性评估运动降解、鬼影/相位错位伪影、星芒/径向编码伪影、脂肪抑制质量和整体诊断质量五个类别。
  • 通过手动绘制感兴趣区分析定量评估SNR和CNR。
  • 鬼影和相位伪影BLADE序列更低(p<0.001),条纹伪影BLADE序列更高(p<0.001)。
  • 脂肪抑制、肌腱和盂唇表现、整体SNR和CNR两序列相当(p>0.05)。

临床应用与阅片要点

  • 对怀疑运动伪影的患者可应用BLADE序列以减少重复成像频率。
  • BLADE可能减少总成像时间和召回,从而降低患者和医疗系统成本负担。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: MR imaging of joints, particularly shoulder, requires a high degree of spatial resolution to ascertain anatomy and pathology. Unfortunately, motion artifacts can reduce the clinical quality of the examinations. BLADE sequence reduces motion degradation improving overall diagnostic imaging quality. The objective was to compare standard, rectilinear k-space coverage turbo spin echo (TSE), and BLADE sequences.

MATERIAL AND METHODS: Over a 4-month period, fifty-seven consecutive patients (22 males, 35 females; mean age: 48.5 years, range: 23-64 years) were scanned using traditional intermediate-weighted spin echo and BLADE sequences. Qualitative evaluation was performed by three musculoskeletal fellowship trained radiologists, each with more than 5 years of experience. Image sequences were evaluated using a Likert scale for each of the following five categories: motion degradation, ghosting/phase misregistration artifacts, star/radial encoding artifacts, fat suppression quality, and overall diagnostic quality. Additionally, image sequences were evaluated for signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) using manually drawn regions of interest (ROI) analysis.

RESULTS: Ghosting and phase artifacts were lower within BLADE sequence while streak artifacts were higher (p < 0.001). Image fat suppression, tendon and labral appearances, and the overall SNR and CNR were comparable on both sequences (p > 0.05).

CONCLUSION: Addition of BLADE reduces motion degradation and improves overall diagnostic imaging quality. Application of BLADE in patient scans suspected of motion artifacts can reduce the frequency of repeat imaging in patients with claustrophobia or those where motion is a concern. By reducing overall imaging time and call backs, it could reduce the cost burden to patients and healthcare system.

来源:Skeletal Radiol,查看原文。版权归原作者所有。