一个大型美国医疗系统应对全球碘对比剂短缺的策略

A Health System's Response to the Ongoing Global Shortage of Iodinated Contrast Media.
PubMed 文献 · AJR Am J Roentgenol · 2022-06-22

本文描述一个美国大型医疗系统在COVID-19疫情期间全球碘对比剂短缺下,通过采购增补、分装现有库存、用平扫CT或替代影像设备替代增强CT、与放射科以外专科协作节约,并对CT协议进行双能技术及/或降低管电压的个体化调整,以较低对比剂剂量维持组织强化显示。

要点

  • 短缺期间可用平扫CT或替代影像设备替代增强CT。
  • 通过双能技术及/或降低管电压的CT协议个体化调整,降低对比剂剂量并维持组织强化显示。
  • 系统层面行动、操作灵活性和多学科密切沟通是缓解短缺影响的关键。

核心结论

  • 该医疗系统在短缺期间实施的策略为对比剂剂量长期降低和供应恢复后持续的CT协议优化提供了经验。

研究设计与样本

  • 本文描述一个美国大型医疗系统在COVID-19疫情期间全球碘对比剂短缺下实施的应对策略。

临床应用与阅片要点

  • 短缺期间可尝试采购增补、分装现有库存用于更多患者、使用平扫CT或替代影像设备替代增强CT。
  • 可与放射科以外专科协作参与节约努力。
  • 个体化调整CT协议使用双能技术及/或降低管电压,以较低对比剂剂量维持组织强化显示。
  • 缓解短缺影响的关键是系统层面行动、操作灵活性和放射科医生、技师、物理师、药师及开单医生之间的密切沟通。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

A production facility shutdown related to containment measures during the COVID-19 pandemic has resulted in a global shortage of iodinated contrast media. This article describes the strategies implemented at one large U.S. health system to maintain care continuity during the ongoing shortage. The strategies have included attempts to procure additional stock, repackage existing stock for use in larger numbers of patients, use noncontrast CT or alternative imaging modalities in place of contrast-enhanced CT, and collaborate with specialties outside of radiology to participate in conservation efforts. In addition, individual CT protocols underwent tailored modifications to use dual-energy technique and/or lower tube voltages, to allow lower contrast media doses with maintained visualization of tissue enhancement. The experiences during this period provide insights to facilitate long-term reductions in contrast media doses and ongoing CT protocol optimization after supplies return to normal levels. Critical throughout the efforts to mitigate the impact of the shortage have been system-level action, operational flexibility, and close communication by the health system's radiologists, technologists, physicists, pharmacists, and ordering providers.

来源:AJR Am J Roentgenol,查看原文。版权归原作者所有。