文献速递泌尿生殖技术与安全CT

膀胱癌患者CT体成分测量的自动分析与手动分析比较

Automated versus manual analysis of body composition measures on computed tomography in patients with bladder cancer.
PubMed 文献 · Eur J Radiol · 2022-06-16

本研究回顾性分析1996至2017年杜克大学健康系统285例膀胱癌患者的腹部CT,在L3层面比较自动分割软件ABACS与手动分割(Slice-O-Matic)测量骨骼肌、皮下脂肪和内脏脂肪面积的性能。结果显示两种方法在面积测量上高度一致(PPMCC和ICC3均>0.90),基于已发表截断值的肌少症、皮下脂肪过多和内脏脂肪过多分类的kappa值分别为0.73、0.88和0.90,提示ABACS自动分割与手动分析表现相似,可能加速体成分研究的数据收集。

要点

  • ABACS自动分割与手动分割在L3层面测量骨骼肌、皮下脂肪和内脏脂肪面积高度一致(PPMCC>0.90,ICC3>0.90)。
  • 基于已发表截断值分类肌少症、皮下脂肪过多、内脏脂肪过多时,两种方法的kappa值分别为0.73、0.88、0.90。
  • 作者认为ABACS自动分割表现与手动分析相似,可能加速体成分研究的数据收集。

核心结论

  • ABACS自动分割CT体成分测量与手动分析表现相似,可能加速体成分研究的数据收集。

研究设计与样本

  • 回顾性分析1996至2017年杜克大学健康系统285例膀胱癌患者的腹部CT,手动分割使用Slice-O-Matic,自动分割使用ABACS,均在L3层面进行,参考标准为手动分割。

诊断标准与关键数值

  • 测量指标为骨骼肌面积、皮下脂肪面积和内脏脂肪面积,并计算骨骼肌指数、皮下脂肪指数和内脏脂肪指数(各面积除以身高平方,m²);采用已发表截断值将患者分为肌少症、皮下脂肪过多或内脏脂肪过多;手动与自动分割的一致性评估使用Pearson积矩相关系数、组内相关系数(ICC3)和kappa统计量。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: Manual measurement of body composition on computed tomography (CT) is time-consuming, limiting its clinical use. We validate a software program, Automatic Body composition Analyzer using Computed tomography image Segmentation (ABACS), for the automated measurement of body composition by comparing its performance to manual segmentation in a cohort of patients with bladder cancer.

METHOD: We performed a retrospective analysis of 285 patients treated for bladder cancer at the Duke University Health System from 1996 to 2017. Abdominal CT images were manually segmented at L3 using Slice-O-Matic. Automated segmentation was performed with ABACS on the same L3-level images. Measures of interest were skeletal muscle (SM) area, subcutaneous adipose tissue (SAT) area, and visceral adipose tissue (VAT) area. SM index, SAT index, and VAT index were calculated by dividing component areas by patient height2 (m2). Patients were dichotomized as sarcopenic, having excessive subcutaneous fat, or having excessive visceral fat using published cut-off values. Agreement between manual and automated segmentation was assessed using the Pearson product-moment correlation coefficient (PPMCC), the interclass correlation coefficient (ICC3), and the kappa statistic (κ).

RESULTS: There was strong agreement between manual and automatic segmentation, with PPMCCs > 0.90 and ICC3s > 0.90 for SM, SAT, and VAT areas. Categorization of patients as sarcopenic (κ = 0.73), having excessive subcutaneous fat (κ = 0.88), or having excessive visceral fat (κ = 0.90) displayed high agreement between methods.

CONCLUSIONS: Automated segmentation of body composition measures on CT using ABACS performs similarly to manual analysis and may expedite data collection in body composition research.

来源:Eur J Radiol,查看原文。版权归原作者所有。

引用

  1. Rigiroli, Zhang, Molinger, et al. Automated versus manual analysis of body composition measures on computed tomography in patients with bladder cancer. Eur J Radiol. 2022. PMID: 35732083. doi:10.1016/j.ejrad.2022.110413

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。