文献速递腹部技术与安全CT

基于图像的去噪算法应用于辐射剂量降低的多期腹部CT检查:在低对比度与高对比度诊断任务中的诊断性能

Diagnostic Performance in Low- and High-Contrast Tasks of an Image-Based Denoising Algorithm Applied to Radiation Dose-Reduced Multiphase Abdominal CT Examinations.
PubMed 文献 · AJR Am J Roentgenol · 2022-06-22

该回顾性单中心研究纳入47例已知或疑似肝转移患者(低对比度任务)和45例胰腺癌分期患者(高对比度任务),采用噪声插入技术创建剂量降低50%以上的图像,再用频率分割多频带滤波算法去噪。结果显示去噪后低剂量图像在肝转移检测(JAFROC FOM 0.644 vs 0.668,差异-0.024,95%CI -0.084至0.037)和胰腺癌血管侵犯评估(κ=0.53-1.00,置信度评分差异95%CI均包含零)方面与常规剂量图像性能相似。

要点

  • 频率分割多频带滤波算法可在不依赖投影数据的情况下对多期腹部CT图像本身进行去噪。
  • 剂量降低≥50%的去噪图像在肝转移检测中与常规剂量图像非劣效(FOM差异-0.024,非劣效界值-0.10)。
  • 胰腺癌血管侵犯评估中,去噪低剂量与常规剂量图像的读者间一致性为中等至近乎完美(κ=0.53-1.00)。

核心结论

  • 多期增强腹部CT图像经频率分割多频带滤波算法去噪后,在肝转移检测和胰腺癌血管分期方面性能与常规剂量图像相似,可实现辐射剂量降低50%以上。

研究设计与样本

  • 回顾性单中心研究,纳入47例已知或疑似肝转移患者(低对比度任务,3名腹部放射科医师独立评估)和45例胰腺癌分期患者(高对比度任务,4名腹部放射科医师独立评估);采用验证过的噪声插入技术创建剂量降低≥50%的图像,再经频率分割多频带滤波算法去噪。

诊断标准与关键数值

  • 肝转移检测采用JAFROC品质因子(FOM),非劣效界值为-0.10;去噪低剂量图像FOM为0.644(95%CI 0.510-0.778),常规剂量图像FOM为0.668(95%CI 0.543-0.792),估计差异为-0.024(95%CI -0.084至0.037)。胰腺癌血管侵犯评估采用Cohen kappa统计量和读者置信度评分(100分制);两套图像集比较的观察者内一致性κ=0.53-1.00,置信度评分差异的95%CI均包含零。

临床应用与阅片要点

  • 该基于图像的去噪算法可作为商用迭代重建算法的补充,实现多期检查的辐射剂量降低,且不需要制造商特定硬件或软件;对于低对比度和高对比度诊断任务均可应用。

局限性

  • 原文未报告局限性

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

BACKGROUND. Anatomic redundancy between phases can be used to achieve denoising of multiphase CT examinations. A limitation of iterative reconstruction (IR) techniques is that they generally require use of CT projection data. A frequency-split multi-band-filtration algorithm applies denoising to the multiphase CT images themselves. This method does not require knowledge of the acquisition process or integration into the reconstruction system of the scanner, and it can be implemented as a supplement to commercially available IR algorithms. OBJECTIVE. The purpose of the present study is to compare radiologists' performance for low-contrast and high-contrast diagnostic tasks (i.e., tasks for which differences in CT attenuation between the imaging target and its anatomic background are subtle or large, respectively) evaluated on multiphase abdominal CT between routine-dose images and radiation dose-reduced images processed by a frequency-split multiband-filtration denoising algorithm. METHODS. This retrospective single-center study included 47 patients who underwent multiphase contrast-enhanced CT for known or suspected liver metastases (a low-contrast task) and 45 patients who underwent multiphase contrast-enhanced CT for pancreatic cancer staging (a high-contrast task). Radiation dose-reduced images corresponding to dose reduction of 50% or more were created using a validated noise insertion technique and then underwent denoising using the frequency-split multi-band-filtration algorithm. Images were independently evaluated in multiple sessions by different groups of abdominal radiologists for each task (three readers in the low-contrast arm and four readers in the high-contrast arm). The noninferiority of denoised radiation dose-reduced images to routine-dose images was assessed using the jackknife alternative free-response ROC (JAFROC) figure-of-merit (FOM; limit of noninferiority, -0.10) for liver metastases detection and using the Cohen kappa statistic and reader confidence scores (100-point scale) for pancreatic cancer vascular invasion. RESULTS. For liver metastases detection, the JAFROC FOM for denoised radiation dose-reduced images was 0.644 (95% CI, 0.510-0.778), and that for routine-dose images was 0.668 (95% CI, 0.543-0.792; estimated difference, -0.024 [95% CI, -0.084 to 0.037]). Intraobserver agreement for pancreatic cancer vascular invasion was substantial to near perfect when the two image sets were compared (κ = 0.53-1.00); the 95% CIs of all differences in confidence scores between image sets contained zero. CONCLUSION. Multiphase contrast-enhanced abdominal CT images with a radiation dose reduction of 50% or greater that undergo denoising by a frequency-split multiband-filtration algorithm yield performance similar to that of routine-dose images for detection of liver metastases and vascular staging of pancreatic cancer. CLINICAL IMPACT. The image-based denoising algorithm facilitates radiation dose reduction of multiphase examinations for both low- and high-contrast diagnostic tasks without requiring manufacturer-specific hardware or software.

来源:AJR Am J Roentgenol,查看原文。版权归原作者所有。

引用

  1. Inoue, Voss, Lee, et al. Diagnostic Performance in Low- and High-Contrast Tasks of an Image-Based Denoising Algorithm Applied to Radiation Dose-Reduced Multiphase Abdominal CT Examinations. AJR Am J Roentgenol. 2022. PMID: 35731096. doi:10.2214/AJR.22.27806

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。