本研究以临床脑死亡诊断为参考标准,比较10分、7分和4分CT血管造影评分系统在50例儿童中的敏感度与观察者间一致性。4分法敏感度最高(A0-V50法92%,A50-V50法82%),前囟未闭患儿敏感度明显低于骨完整性保留及去骨瓣减压组。作者认为各评分系统敏感度相近,可作为儿科脑死亡的辅助检查。
要点
- 儿童脑死亡CT血管造影评估中,4分法敏感度高于10分法和7分法。
- 前囟未闭患儿CT血管造影诊断脑死亡的敏感度明显低于骨完整性保留组和去骨瓣减压组。
- 各评分系统观察者间一致率多数超过90%,7分法A0-V50法为78%。
核心结论
- 与成人相同,儿童CT血管造影评估脑死亡时4分法似乎比10分法和7分法更敏感;因各评分系统敏感度相近,可作为儿科病例的辅助检查。
研究设计与样本
- 以临床脑死亡诊断为参考标准,回顾性评估50例临床诊断脑死亡患儿的CT血管造影,按10分、7分和4分评分系统由两名放射科医生分别于动脉期(A0-V50)和静脉期(A0-V50)评估血管充盈。
关键影像表现/征象
- 按年龄分为≤2岁和>2岁两组并分别计算敏感度。
- 比较去骨瓣减压缺损、前囟未闭与骨完整性保留三组患儿的脑死亡诊断差异。
诊断标准与关键数值
- 以临床检查为参考标准,10分法敏感度在A0-V50法为70%、A50-V50法为40%。
- 7分法敏感度在A0-V50法为88%、A50-V50法为82%。
- 4分法敏感度在A0-V50法为92%、A50-V50法为82%。
- 7分法A0-V50法观察者间一致率为78%,其他评分系统在A0-V50法和A50-V50法均超过90%。
临床应用与阅片要点
- 儿童脑死亡CT血管造影评估可参考4分法,其敏感度高于10分法和7分法。
- 前囟未闭患儿CT血管造影诊断脑死亡的敏感度明显低于骨完整性保留组和去骨瓣减压组。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
BACKGROUND: The diagnosis of brain death is primarily clinical. Sometimes ancillary tests are needed.
OBJECTIVE: This study compared sensitivity and interobserver agreement of the 10-, 7- and 4-point CT angiography scoring systems for the diagnosis of brain death in children.
MATERIALS AND METHODS: CT angiography examinations of 50 pediatric patients with a clinical diagnosis of brain death were evaluated according to 10-, 7- and 4-point scoring systems. Images were evaluated by two radiologists who considered the vessel opacification first in the arterial phase (A0-V50) and then in the venous phase (A0-V50). We evaluated interobserver agreement for the assessment of vessel opacification and diagnosis of brain death. We compared the differences among brain death diagnoses between children with craniotomy-craniectomy defects, open fontanelles and preserved bone integrity. We subdivided children into two groups according to age: ≤ 2 years and > 2 years. We calculated sensitivities according to age groups.
RESULTS: Using the clinical exam as the reference standard, we found sensitivities for 10-, 7- and 4-point scoring systems to be 70%, 88% and 92% in the A0-V50 method and 40%, 82% and 82% in the A50-V50 method, respectively. Percentage agreement between readers was 78% for the 7-point scale using the A0-V50 method and more than 90% for other scoring systems for both the A0-V50 method and the A50-V50 method. The sensitivity was much lower in children with open anterior fontanelles compared to the groups with preserved bone integrity and with a craniotomy-craniectomy defect.
CONCLUSION: Just as in adult age groups, in children the 4-point scale appears to be more sensitive than the 10- and 7-point scales for CT angiography-based assessment of brain death. Because the scoring systems have similar sensitivities, they could be used as ancillary tests in pediatric cases.
引用
- Almus, Bıyıklı, Yapıcı, et al. Brain death in children: is computed tomography angiography reliable as an ancillary test? Pediatr Radiol. 2022. PMID: 35731261. doi:10.1007/s00247-022-05419-2