CT血管成像诊断颈动脉近闭塞:一项数字减影血管造影验证研究
本研究以数字减影血管造影为参考标准,在58例颈动脉狭窄或闭塞患者中验证CT血管成像诊断颈动脉近闭塞的新视觉标准及既往标准。新标准中「远端颈内动脉直径小于或等于同侧颈外动脉」的敏感度为79%、特异度为83%,观察者间一致性极好(kappa=0.80);既往标准中满足3条及以上者敏感度82%、特异度90%,一致性良好(kappa=0.64)。作者认为CT血管成像可能有助于颈动脉近闭塞诊断,但假阴性和假阳性结果仍存在。
要点
- 新标准「远端颈内动脉直径≤同侧颈外动脉」诊断颈动脉近闭塞敏感度79%、特异度83%,观察者间一致性极好(kappa=0.80)。
- 既往标准中满足3条及以上者敏感度82%、特异度90%,观察者间一致性良好(kappa=0.64)。
- CT血管成像可能有助于颈动脉近闭塞诊断,但假阴性和假阳性结果仍存在。
核心结论
- CT血管成像可能有助于颈动脉近闭塞诊断。
- 新的视觉诊断标准提供了可接受的敏感度和特异度,且观察者间一致性极好。
- 假阴性和假阳性结果仍存在。
研究设计与样本
- 研究纳入58例数字减影血管造影显示颈内动脉狭窄(包括近闭塞变异型)或闭塞的患者,数字减影血管造影与CT血管成像检查间隔在30天内完成。
- 以数字减影血管造影为参考标准,由两名对数字减影血管造影结果不知情的神经放射科医生评估CT血管成像图像并评价新旧颈动脉近闭塞诊断标准。
关键影像表现/征象
- 数字减影血管造影识别出28例颈动脉近闭塞。
诊断标准与关键数值
- 新标准「远端颈内动脉直径小于或等于同侧颈外动脉」:敏感度79%,特异度83%,观察者间一致性kappa=0.80(极好)。
- 既往标准中满足3条及以上:敏感度82%,特异度90%,观察者间一致性kappa=0.64(良好)。
- 既往评估的CT血管成像标准包括:狭窄≤1.3 mm、同侧远端颈内动脉≤3.5 mm、同侧远端颈内动脉/对侧远端颈内动脉比值≤0.87、同侧远端颈内动脉/同侧颈外动脉≤1.27。
临床应用与阅片要点
- 作者认为CT血管成像可能有助于颈动脉近闭塞诊断,新视觉标准提供了可接受的敏感度和特异度及极好的观察者间一致性。
- 作者指出假阴性和假阳性结果仍存在。
局限性
- 假阴性和假阳性结果仍存在。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
INTRODUCTION: Carotid near-occlusion (CNO) is a variant of severe stenosis where there is a distal luminal collapse of the internal carotid artery (ICA) beyond a tight stenosis. This study aimed to validate new visual extracranial diagnostic CT angiography (CTA) criteria, for the diagnosis of CNO. The new criteria include distal ICA diameter smaller than contralateral ICA and distal ICA diameter less than or equal to the ipsilateral external carotid artery (ECA). We also assessed the previously described CTA criteria: stenosis ≤ 1.3 mm, ipsilateral distal ICA ≤ 3.5 mm, ipsilateral distal ICA/contralateral distal ICA ratio ≤ 0.87, ipsilateral distal ICA/ipsilateral ECA ≤ 1.27.
METHODS: Fifty-eight patients with ICA stenosis (including the near-occlusion variant) or occlusion on digital subtraction angiography (DSA) were included. These patients had DSA and CTA studies completed within 30 days of each other. DSA was considered the reference test. Two neuroradiologists blinded to the DSA results assessed the CTA images and evaluated the new and previously published CNO diagnostic criteria.
RESULTS: Twenty-eight CNO were identified with DSA. The "distal ICA diameter less than or equal to the ipsilateral ECA" criterion had 79% sensitivity and 83% specificity with excellent interobserver agreement (kappa = 0.80), while three or more of the previously published criteria reached 82% sensitivity and 90% specificity, with a good interobserver agreement (kappa = 0.64).
CONCLUSIONS: CT angiography may be useful for CNO diagnosis. The new visual diagnostic criteria provide acceptable results of sensitivity and specificity with an excellent interobserver agreement. However, false-negative and positive results persist.
引用
- Manrique-Zegarra, García-Pastor, Castro-Reyes, et al. CT angiography for diagnosis of carotid near-occlusion: a digital subtraction angiography validation study. Neuroradiology. 2022. PMID: 35729332. doi:10.1007/s00234-022-02995-w
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。