文献速递腹部泌尿生殖MR

基于MRI影像组学与机器学习的实性肾脏病变良恶性鉴别

Differentiation of benign from malignant solid renal lesions with MRI-based radiomics and machine learning.
PubMed 文献 · Abdom Radiol (NY) · 2022-06-20

本研究从机构数据库筛选160例患者共182个实性肾脏病变,在T2加权及增强T1加权图像上分割并提取影像组学特征,训练十种机器学习算法区分良恶性。基于T2加权图像特征的支持向量机表现最优,准确度0.80、AUC 0.79;基于增强T1或双序列组合的算法表现较低。结论认为基于T2加权图像影像组学的机器学习模型可高准确度鉴别实性肾脏病变良恶性。

要点

  • 基于T2加权图像影像组学的支持向量机鉴别实性肾脏病变良恶性准确度0.80、AUC 0.79。
  • 线性判别分析准确度0.84、AUC 0.77,逻辑回归准确度0.78、AUC 0.78,表现与支持向量机相近。
  • 基于增强T1加权图像或T2与增强T1组合特征的机器学习算法表现较低。

核心结论

  • 基于T2加权图像影像组学特征训练的机器学习模型可高准确度区分实性肾脏病变的良恶性。

研究设计与样本

  • 从机构数据库筛选干预前MRI发现实性肾脏病变的患者,纳入经影像(血管平滑肌脂肪瘤)或活检/手术切除(嗜酸细胞瘤或肾细胞癌)明确诊断的病变,共182个病变、160例患者;每个病变在T2加权和增强T1加权图像上分割并提取影像组学特征,用十种机器学习算法分别基于各序列及序列组合特征训练。

诊断标准与关键数值

  • 基于T2加权图像特征的支持向量机准确度0.80、AUC 0.79;线性判别分析准确度0.84、AUC 0.77;逻辑回归准确度0.78、AUC 0.78;基于增强T1加权图像或T2与增强T1组合特征的算法表现较低。

临床应用与阅片要点

  • 作者认为基于MRI影像组学特征的机器学习模型可能改善实性肾脏病变的临床管理,并有可能减少良性实性肾脏病变被活检或手术切除的频率。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

BACKGROUND: Solid renal masses are often indeterminate for benignity versus malignancy on magnetic resonance imaging. Such masses are typically evaluated with either percutaneous biopsy or surgical resection. Percutaneous biopsy can be non-diagnostic and some surgically resected lesions are inadvertently benign.

PURPOSE: To assess the performance of ten machine learning (ML) algorithms trained with MRI-based radiomics features in distinguishing benign from malignant solid renal masses.

METHODS: Patients with solid renal masses identified on pre-intervention MRI were curated from our institutional database. Masses with a definitive diagnosis via imaging (for angiomyolipomas) or via biopsy or surgical resection (for oncocytomas or renal cell carcinomas) were selected. Each mass was segmented for both T2- and post-contrast T1-weighted images. Radiomics features were derived from the segmented masses for each imaging sequence. Ten ML algorithms were trained with the radiomics features gleaned from each MR sequence, as well as the combination of MR sequences.

RESULTS: In total, 182 renal masses in 160 patients were included in the study. The support vector machine algorithm trained on radiomics features from T2-weighted images performed superiorly, with an accuracy of 0.80 and an area under the curve (AUC) of 0.79. Linear discriminant analysis (accuracy = 0.84 and AUC = 0.77) and logistic regression (accuracy = 0.78 and AUC = 0.78) algorithms trained on T2-based radiomics features performed similarly. ML algorithms trained on radiomics features from post-contrast T1-weighted images or the combination of radiomics features from T2- and post-contrast T1-weighted images yielded lower performance.

CONCLUSION: Machine learning models trained with radiomics features derived from T2-weighted images can provide high accuracy for distinguishing benign from malignant solid renal masses.

CLINICAL IMPACT: Machine learning models derived from MRI-based radiomics features may improve the clinical management of solid renal masses and have the potential to reduce the frequency with which benign solid renal masses are biopsied or surgically resected.

来源:Abdom Radiol (NY),查看原文。版权归原作者所有。

引用

  1. Massa'a, Stoeckl, Lubner, et al. Differentiation of benign from malignant solid renal lesions with MRI-based radiomics and machine learning. Abdom Radiol (NY). 2022. PMID: 35723716. doi:10.1007/s00261-022-03577-3

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。