双梯度回波同相位与反相位序列评估β地中海贫血患者肝脏铁过载是否更优
研究纳入63例β地中海贫血患儿,在1.5T MRI上计算肝脏轴位中段R2*弛豫测量值与双梯度回波同反相位序列的相对信号强度指数并做相关分析;双梯度回波同反相位序列视觉评估准确评估了93.65%的肝脏铁过载患者,相对信号强度指数与R2*弛豫测量值显著相关(p < 0.001,r = 0.861)。
要点
- 双梯度回波同反相位序列视觉评估可准确评估93.65%的β地中海贫血患儿肝脏铁过载。
- 相对信号强度指数与肝脏MRI R2*弛豫测量值显著相关(p < 0.001,r = 0.861)。
- 作者认为双梯度回波同反相位序列是检测和量化肝脏铁的良好影像工具。
核心结论
- 双梯度回波同相位与反相位序列是检测和量化肝脏铁的良好影像工具,与R2*弛豫测量值相关性良好(r = 0.861,p < 0.001)。
研究设计与样本
- 研究纳入63例重型(输血依赖)或中间型(输血依赖及非输血依赖)β地中海贫血患者,由儿科血液科转诊至大学医院放射科,使用1.5T MR扫描仪(Achieva;Philips Medical Systems,荷兰)行R2*弛豫测量和双梯度回波序列,计算肝脏轴位中段R2*与相对信号强度指数并分析相关性。
关键影像表现/征象
- 双梯度回波同相位与反相位序列视觉评估准确评估了93.65%的肝脏铁过载患者。
- 相对信号强度指数与肝脏MRI R2*弛豫测量值显著相关(p < 0.001,r = 0.861)。
诊断标准与关键数值
- 双梯度回波同相位与反相位序列视觉评估对肝脏铁过载的准确评估率为93.65%。
- 相对信号强度指数与肝脏MRI R2*弛豫测量值的相关性为r = 0.861,p < 0.001。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
PURPOSE: To evaluate the diagnostic accuracy of the dual gradient-echo (GRE) in- and out-of-phase sequences as a quantitative tool for hepatic iron overload in comparison with MRI R2* relaxometry in paediatric patients with beta-thalassemia.
METHOD: Sixty-three patients with beta-thalassemia major (transfusion-dependent) or beta-thalassemia intermedia (transfusion- and non-transfusion-dependent) were referred from the paediatric department (haematology unit) to the radiology department at a university hospital. The paediatrician conducted a clinical examination for the studied group, assessed their laboratory data, conducted R2* relaxometry and dual gradient echo sequences to calculate R2* and relative signal intensity index at the axial mid-section of the liver, and studied their correlation. A 1.5 Tesla MR scanner was used (Achieva; Philips Medical Systems, the Netherlands). Data were fed to the computer and analysed using the IBM SPSS software package version 20.0 (Armonk, NY: IBM Corp). The Kolmogorov-Smirnov test was used to verify the normality of distribution. The significance of the results was determined at the 5% level. The Chi-square, Fisher's exact correction, Pearson coefficient, and Bland-Altman tests were used.
RESULTS: Dual gradient-echo in- and out-of-phase sequences using visual assessment accurately assessed 93.65% of our patient group with hepatic iron overload. A significant correlation was found between the relative signal intensity index and hepatic MRI R2* relaxometry (p < 0.001, r = 0.861).
CONCLUSIONS: Dual gradient-echo in and out-of-phase sequences are good imaging tools for hepatic iron detection and quantification. These sequences showed good correlation with R2* relaxometry (r = 0.861, p < 0.001).
引用
- Ali Mohamed Aboughonaim, Naguib Ettaby, Ibrahim El-Noueum, et al. Dual gradient echo in-phase and out of phase sequences in assessment of hepatic iron overload in patients with beta-thalassemia, would be better? Eur J Radiol. 2022. PMID: 35724580. doi:10.1016/j.ejrad.2022.110412
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。