混合CT血管造影(Angio-CT)用于介入放射学中CT与透视联合操作可提升使用效率
该研究回顾性分析了2018年6月至2019年8月间在Angio-CT系统上完成的1108例介入操作,其中10%(114/1108)同时使用了透视和CT。在非复杂捆绑病例中,82.5%(14/17)的房间时间低于各自对照组的均值。结论认为Angio-CT主要用于非肿瘤、非复杂病例,并可能减少特定非复杂捆绑病例的房间时间和总 encounter 时间。
要点
- Angio-CT主要用于非肿瘤(70%)和非复杂(59%)病例。
- 肺活检后气胸置入胸膜导管经Angio-CT完成时房间时间显著低于对照组(99 vs. 163 min,p<0.0001)。
- 腹部/盆腔引流管置入捆绑肾造瘘管评估或中心静脉导管置入时总 encounter 时间显著降低。
核心结论
- 混合Angio-CT系统的主要用途是执行非肿瘤和非复杂病例,对于特定的非复杂捆绑病例,可能减少房间时间和总 encounter 时间。
研究设计与样本
- 回顾性分析,纳入2018年6月至2019年8月期间通过Angio-CT系统完成的1108例介入操作,按RVUs定义的复杂程度分层,比较非复杂捆绑病例与对照组的房间时间和总 encounter 时间。
关键影像表现/征象
- 1108例操作中10%(114/1108)同时使用透视和CT。
- 114例中21%(24/114)为单次 encounter 内涉及多个操作且需要CT-only和透视-only捆绑的病例。
- 114例中59%(67/114)为非复杂病例,70%(80/114)为非肿瘤病例。
诊断标准与关键数值
- 非复杂捆绑操作中82.5%(14/17)的房间时间低于各自对照组的均值。
- 非复杂捆绑操作中52.8%(9/17)的房间时间低于对照组均值的2个标准差。
- 肺活检后气胸置入胸膜导管经Angio-CT vs. 对照组:房间时间99 vs. 163 min,p<0.0001。
- 腹部/盆腔引流管置入捆绑经皮肾造瘘管评估(伴或不伴更换)经Angio-CT vs. 对照组:总 encounter 时间211 min vs. 344 min,p<0.001。
- 腹部/盆腔引流管置入捆绑中心静脉导管置入经Angio-CT vs. 对照组:总 encounter 时间231 min vs. 347 min,p<0.05。
临床应用与阅片要点
- Angio-CT系统可用于单次 encounter 内联合CT和透视完成多个操作或单一联合操作。
- 对于非复杂捆绑病例(如肺活检后气胸置入胸膜导管、腹部/盆腔引流管置入捆绑肾造瘘管评估或中心静脉导管置入),Angio-CT可能减少房间时间或总 encounter 时间。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
PURPOSE: To investigate the utilization of an angiography-CT (Angio-CT) system and its advantages for single patient encounters.
METHODS: Interventions utilizing both CT and fluoroscopy to perform multiple procedures in a single encounter or single interventions using both were identified. Cases were stratified by complexity (defined by RVUs). Comparative analyses of room (TRoom) and total encounter (TEncounter) times were performed between non-complex bundled cases and controls.
RESULTS: Between June 2018 and August 2019, 1108 procedures were performed via the Angio-CT system; 10% (114/1108) used both fluoroscopy and CT. 21% (24/114) Involved more than one procedure in a single encounter that required a CT-only and fluoroscopy-only bundled procedure. 59% (67/114) were non-complex, and 70% (80/114) were non-oncologic. 82.5% (14/17) of non-complex bundled procedures demonstrated TRoom below the mean of their respective controls; 52.8% (9/17) were 2 standard deviations below the control means. Pleural catheter placement following post-lung biopsy pneumothorax was the most common non-complex bundled case with a significant reduction in TRoom when performed via Angio-CT compared to control (99 vs. 163 min, p < 0.0001). There was a significant reduction in TEncounter for abdominopelvic drain placement procedures bundled with either (1) percutaneous nephrostomy tube evaluation with or without replacement, or (2) central venous catheter placement (211 min vs. 344 min, p < 0.001 and 231 min vs. 347 min, p < 0.05, respectively).
CONCLUSION: The primary use for the hybrid Angio-CT system was to perform non-oncologic and non-complex cases with potential reduction in TRoom and TEncounter for specific non-complex bundled cases.
引用
- Kwak, Ahmed, Habib, et al. Hybrid CT-angiography (Angio-CT) for combined CT and fluoroscopic procedures in interventional radiology enhances utilization. Abdom Radiol (NY). 2022. PMID: 35723717. doi:10.1007/s00261-022-03576-4
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。