高帧率向量血流成像定量评估颈动脉血流湍流
研究用高帧率向量血流成像定量评估40名健康志愿者颈动脉血流,以湍流指数(Tur)比较颈总动脉(CCA)与颈动脉球(CB)在不同年龄和心动周期的血流模式;CB的Tur值在收缩期和舒张期均高于CCA(P < .001),收缩期CB的Tur值高于舒张期(P < .001),CB的Tur值与近端颈内动脉/颈总动脉直径比正相关(ρ = 0.69,P < .05)。
要点
- CB的Tur值在收缩期和舒张期均显著高于CCA(P < .001)。
- 收缩期CB的Tur值显著高于舒张期(P < .001)。
- CB的Tur值与近端颈内动脉/颈总动脉直径比正相关(ρ = 0.69,P < .05)。
核心结论
- V Flow成像提供的Tur指数是颈动脉血流定量分析的可靠方法,可能进一步用于区分颈动脉疾病高危人群的复杂血流动力学特征,以进行心血管事件风险分层。
研究设计与样本
- 研究纳入40名健康志愿者,采用高帧率向量血流成像定量评估颈动脉血流特征;根据收缩期CB复杂血流的分布范围定义三种血流模式;比较不同年龄组和心动周期CCA与CB的平均Tur值,并检验Tur值与近端颈内动脉/颈总动脉直径比(DRpro-ica/cca)的相关性。
关键影像表现/征象
- CB的复杂血流在40名参与者中存在差异,尤其在收缩期;而CCA的血流模式相对一致。
- CB的Tur值在收缩期和舒张期均显著高于CCA(P < .001)。
- 收缩期CB的Tur值显著高于舒张期(P < .001)。
诊断标准与关键数值
- 根据收缩期CB复杂血流的分布范围定义三种血流模式。
- CB的Tur值与DRpro-ica/cca正相关(ρ = 0.69,P < .05)。
临床应用与阅片要点
- V Flow成像的Tur指数可用于定量分析颈动脉血流。
- 作者认为Tur指数可能进一步应用于区分颈动脉疾病高危人群的复杂血流动力学特征,以进行心血管事件风险分层。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVES: To assess the feasibility and performance of Turbulence (Tur) index as a quantitative tool for carotid artery flow turbulence; to detect and compare the blood flow patterns of common carotid artery (CCA) and carotid bulb (CB) at different ages and cardiac phases in healthy adults, and thus interpret the evolvement of etiology difference between CCA and CB.
METHODS: Carotid flow characteristics of 40 healthy volunteers were evaluated quantitatively by a high-frame rate vector flow imaging. Three types of flow patterns were defined depending on the distributive range of complex flow during systole in CB. Comparison of mean Tur value in CCA and CB at different age groups and cardiac phases was performed. And the correlation between Tur value and the diameter ratio of proximal internal carotid artery to common carotid artery (DRpro-ica/cca) was tested.
RESULTS: Mean Tur values in CB were remarkably higher than that in CCA, whether during systole or diastole (P < .001). Meanwhile Tur values in CB during systole were significantly higher than that during diastole (P < .001). Flow complexity of CB showed variations among 40 participants especially in systole, whereas the flow pattern of CCA was relatively consistent. Mean Tur values were positively correlated with DRpro-ica/cca in CB (ρ = 0.69, P < .05).
CONCLUSIONS: V Flow imaging provided a reliable method-Tur, for quantitative analysis of carotid blood flow. It had potential to be further applied in distinguishing complex hemodynamic characteristics in high-risk people of carotid diseases for the risk stratification of cardiovascular events.
引用
- Dong, Hong, Song, et al. Blood Flow Turbulence Quantification of Carotid Artery With a High-Frame Rate Vector Flow Imaging. J Ultrasound Med. 2022. PMID: 35716339. doi:10.1002/jum.16039
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。