文献速递腹部外周血管介入US

评估声触诊弹性成像(STE)在布加综合征(BCS)治疗后短期疗效中的价值:一项病例系列研究

Evaluating short-term outcomes of the value of sound touch elastography (STE) following the treatment for Budd-Chiari syndrome (BCS): a case series study.
PubMed 文献 · Clin Radiol · 2022-06-14

本研究为徐州医科大学附属医院2020年8月至12月的前瞻性病例系列研究,纳入46例布加综合征患者,在血管内治疗前后用声触诊弹性成像测量肝硬度。治疗后肝硬度较治疗前显著降低,肝静脉压力梯度也显著下降,不同Child-Pugh分级组间肝硬度差异显著。作者认为STE可能是评估BCS患者短期疗效的工具。

要点

  • BCS患者血管内治疗后肝硬度较治疗前显著降低(p<0.001)。
  • 治疗前平均肝静脉压力梯度为13.02±3.82 mmHg,干预后下降(p<0.001)。
  • Child-Pugh A、B、C三组间肝硬度差异显著(F=127.01,p<0.001)。

核心结论

  • STE可能是评估BCS患者短期治疗效果的潜在工具。

研究设计与样本

  • 前瞻性病例系列研究,纳入46例诊断为BCS的患者(男23例、女23例),来自徐州医科大学附属医院,时间为2020年8月至2020年12月。
  • 在血管内治疗前按Child-Pugh分级分组(A级24例、B级16例、C级6例),治疗前后用声触诊弹性成像测量肝硬度,并测量肝静脉压力梯度。
  • 肝硬度与肝静脉压力梯度的治疗前后变化采用配对样本t检验比较。

关键影像表现/征象

  • 治疗前与治疗后肝硬度存在显著差异,治疗后肝硬度显著低于治疗前(p<0.001)。
  • 治疗前平均肝静脉压力梯度为13.02±3.82 mmHg,干预后下降(p<0.001)。
  • Child-Pugh A、B、C三组间肝硬度差异显著(F=127.01,p<0.001)。

诊断标准与关键数值

  • 采用Child-Pugh评分标准将患者分为A级24例、B级16例、C级6例。
  • 肝硬度采用声触诊弹性成像测量。
  • 肝静脉压力梯度治疗前平均值为13.02±3.82 mmHg。

临床应用与阅片要点

  • 原文结论认为STE可能是评估BCS患者短期治疗效果的潜在工具。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

AIM: To investigate the value of sound touch elastography (STE) in the evaluation of short-term therapeutic effect of Budd-Chiari syndrome (BCS) by measuring liver stiffness (LS), and in addition, to analyse the relationships between liver function, pressure gradient of the hepatic veins, and LS.

MATERIALS AND METHODS: A case series study was conducted at Affiliated Hospital of Xuzhou Medical University from August 2020 to December 2020. Patients diagnosed with BCS were recruited prospectively and grouped according to Child-Pugh grade before endovascular therapy. LS was measured using STE before and after therapy. Comparisons between the LS and hepatic venous pressure gradient (HVPG) changes of patients were tested with paired sample t-tests.

RESULTS: A total of 46 patients (23 males and 23 females) were included in this study. According to the Child-Pugh scoring criteria, 24 patients were classified as grade A, 16 as grade B, and 6 as grade C. LS was significantly different between the three groups (F = 127.01, p<0.001). Post-treatment LS was significantly lower than pre-treatment (p<0.001). The mean HVPG before treatment was 13.02 ± 3.82 mmHg and decreased after intervention (p<0.001).

CONCLUSION: The STE is a potential tool for evaluating short-term therapeutic effect of BCS patients.

来源:Clin Radiol,查看原文。版权归原作者所有。

引用

  1. Xia, Chen, Wang, et al. Evaluating short-term outcomes of the value of sound touch elastography (STE) following the treatment for Budd-Chiari syndrome (BCS): a case series study. Clin Radiol. 2022. PMID: 35715241. doi:10.1016/j.crad.2022.05.011

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。