直肠癌低位前切除术后常规CT检测吻合口漏的敏感度和特异度低且观察者间一致性差
本研究基于两项前瞻性多中心研究,纳入52例直肠癌低位前切除术后第6-8天行常规腹部CT的患者,比较平扫与直肠对比剂增强CT检测吻合口漏的准确性和观察者间变异。结果显示两位放射科医生诊断敏感度为35.7%-71.4%,特异度为55.3%-94.7%,观察者间变异大;吻合口周围游离气体和对比剂外漏的比值比最高。
要点
- 直肠癌低位前切除术后第6-8天常规CT检测吻合口漏的敏感度和特异度低,观察者间一致性差。
- 吻合口周围游离气体和对比剂外漏对吻合口漏的比值比最高。
- 直肠对比剂增强CT可提高特异度,但敏感度仍有限。
核心结论
- 常规术后CT检测直肠癌低位前切除术后吻合口漏的敏感度和特异度低,且观察者间变异大。
研究设计与样本
- 基于两项前瞻性多中心研究,纳入277例计划术后第6-8天行常规腹部CT的患者,最终52例符合纳入标准(先行平扫CT后行直肠对比剂增强CT),由两位独立资深放射科医生按预设方案盲法阅片,以再手术和/或内镜证实的吻合口漏为参考标准。
关键影像表现/征象
- 吻合口周围游离气体和对比剂外漏对吻合口漏的比值比最高。
诊断标准与关键数值
- 平扫CT诊断吻合口漏的敏感度:放射科医生1为71.4%,放射科医生2为50%。
- 平扫CT诊断吻合口漏的特异度:放射科医生1为55.3%,放射科医生2为81.6%。
- 直肠对比剂增强CT诊断吻合口漏的敏感度:放射科医生1为57.1%,放射科医生2为35.7%。
- 直肠对比剂增强CT诊断吻合口漏的特异度:放射科医生1为94.7%,放射科医生2为92.1%。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
AIM: To compare the accuracy and interobserver variation of routine computed tomography (CT) on postoperative day 6-8 to detect anastomotic leakage (AL) verified by re-operation and/or endoscopy. A secondary objective was to identify the predictive values of different CT findings as an indicator for AL.
MATERIAL AND METHODS: The material for this study originates from two previous prospective multicentre studies including 277 patients who were scheduled for routine abdominal CT postoperative day 6-8. Inclusion criteria for the present study were routine CT without contrast medium followed by CT with rectal contrast medium. Two independent senior radiologists blinded to the clinical outcome reviewed the CT examinations for specific findings according to a predefined scheme.
RESULTS: A total of 52 patients fulfilled the inclusion criteria. AL occurred in 14 patients of which nine were clinical and five subclinical. The two radiologists diagnosed AL at unenhanced CT with sensitivities of 71.4% and 50%, respectively, and of 57.1% and 35.7% with rectal contrast medium. The corresponding specificities were 55.3% and 81.6%, and 94.7% and 92.1%. Peri-anastomotic free air and contrast medium leakage had the highest odds ratios for AL.
CONCLUSION: The diagnostic sensitivity and specificity of routine postoperative CT to detect AL after low anterior resection for rectal cancer is low and with considerable interobserver variation.
引用
- Lynglund, Ellebæk, Al-Dakhiel, et al. Routine postoperative CT to detect anastomotic leakage after low anterior resection for rectal cancer has a low sensitivity and specificity and a poor interobserver agreement. Clin Radiol. 2022. PMID: 35715242. doi:10.1016/j.crad.2022.05.013
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。