基于MRI的脑部危及器官自动分割图谱的开发与评估:基于EPTN共识
研究基于50例匿名脑T1加权MR扫描开发了基于EPTN共识的34个脑部危及器官自动分割图谱,并在另40例MR扫描上测试。31个(91%)危及器官的Dice相似系数≥0.75,29个(85%)被放射肿瘤科医生评为优秀或良好。手动勾画全部危及器官需88.5分钟,而调整自动勾画结果仅需15.8分钟。
要点
- 基于EPTN共识的34个脑部危及器官自动分割图谱在91%的危及器官上Dice相似系数≥0.75。
- 85%的自动勾画危及器官被放射肿瘤科医生评为优秀或良好,仅1个评为差。
- 调整自动勾画结果耗时15.8分钟,远低于手动勾画的88.5分钟。
核心结论
- 脑部危及器官自动分割可在有限时间内实现高质量勾画,准确的危及器官勾画有助于定义危及器官约束以减轻严重并发症,并有助于开发NTCP模型。
研究设计与样本
- 研究使用50例匿名脑T1加权MR扫描(体素大小0.9×0.9×0.9 mm³)在Raystation®治疗计划系统中开发自动分割图谱,并在另40例MR扫描上测试34个按2018年EPTN共识定义的危及器官的自动勾画性能;以手动勾画为参考计算Dice相似系数,由两名放射肿瘤科医生评定自动勾画质量,并记录手动勾画与调整自动勾画所需时间。
诊断标准与关键数值
- 34个自动勾画的危及器官中,31个(91%)的Dice相似系数≥0.75;两名放射肿瘤科医生评定29个(85%)为优秀或良好,4个(12%)为中等,1个(3%)为差;危及器官的观察者间一致性范围为77%–100%。
临床应用与阅片要点
- 调整自动勾画结果耗时15.8分钟,而手动勾画全部危及器官耗时88.5分钟;自动分割有助于在有限时间内完成高质量勾画。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
BACKGROUND AND PURPOSE: During radiotherapy treatment planning, avoidance of organs at risk (OARs) is important. An international consensus-based delineation guideline was recently published with 34 OARs in the brain. We developed an MR-based OAR autosegmentation atlas and evaluated its performance compared to manual delineation.
MATERIALS AND METHODS: Anonymized cerebral T1-weighted MR scans (voxel size 0.9 × 0.9 × 0.9 mm3) were available. OARs were manually delineated according to international consensus. Fifty MR scans were used to develop the autosegmentation atlas in a commercially available treatment planning system (Raystation®). The performance of this atlas was tested on another 40 MR scans by automatically delineating 34 OARs, as defined by the 2018 EPTN consensus. Spatial overlap between manual and automated delineations was determined by calculating the Dice similarity coefficient (DSC). Two radiation oncologists determined the quality of each automatically delineated OAR. The time needed to delineate all OARs manually or to adjust automatically delineated OARs was determined.
RESULTS: DSC was ≥ 0.75 in 31 (91 %) out of 34 automated OAR delineations. Delineations were rated by radiation oncologists as excellent or good in 29 (85 %) out 34 OAR delineations, while 4 were rated fair (12 %) and 1 was rated poor (3 %). Interobserver agreement between the radiation oncologists ranged from 77-100 % per OAR. The time to manually delineate all OARs was 88.5 minutes, while the time needed to adjust automatically delineated OARs was 15.8 minutes.
CONCLUSION: Autosegmentation of OARs enables high-quality contouring within a limited time. Accurate OAR delineation helps to define OAR constraints to mitigate serious complications and helps with the development of NTCP models.
引用
- Crouzen, Petoukhova, Wiggenraad, et al. Development and evaluation of an automated EPTN-consensus based organ at risk atlas in the brain on MRI. Radiother Oncol. 2022. PMID: 35714807. doi:10.1016/j.radonc.2022.06.004