文献速递神经头颈MR

基于EPTN共识的脑部MRI危及器官自动分割图谱的开发与评估

Development and evaluation of an automated EPTN-consensus based organ at risk atlas in the brain on MRI
RSS 订阅 · 指南共识 · 神经影像 · 2022-06-17

研究基于2018年EPTN共识的34个脑部危及器官,用50例T1加权MR扫描在Raystation®治疗计划系统中开发自动分割图谱,并在另40例扫描上测试。31个(91%)危及器官的DSC≥0.75,29个(85%)被放射肿瘤科医生评为优秀或良好;手动勾画全部危及器官需88.5分钟,调整自动勾画结果仅需15.8分钟,作者认为自动分割可在有限时间内实现高质量勾画。

要点

  • 31/34(91%)危及器官自动分割的DSC≥0.75。
  • 29/34(85%)危及器官自动勾画质量被评为优秀或良好。
  • 调整自动勾画用时15.8分钟,远少于手动勾画的88.5分钟。

核心结论

  • 脑部危及器官自动分割可在有限时间内实现高质量勾画,准确的危及器官勾画有助于定义危及器官约束以减轻严重并发症,并有助于开发NTCP模型。

研究设计与样本

  • 研究基于匿名脑部T1加权MR扫描(体素大小0.9×0.9×0.9 mm³),按国际共识手动勾画危及器官,用50例扫描在Raystation®治疗计划系统中开发自动分割图谱,并在另40例扫描上测试34个按2018年EPTN共识定义的危及器官。

诊断标准与关键数值

  • 34个自动危及器官勾画中31个(91%)的Dice相似系数(DSC)≥0.75;放射肿瘤科医生将29/34(85%)评为优秀或良好,4个(12%)评为一般,1个(3%)评为差;两位放射肿瘤科医生间观察者一致性按危及器官为77%–100%。

临床应用与阅片要点

  • 作者认为自动分割可在有限时间内实现高质量勾画,调整自动勾画结果所需时间为15.8分钟,而手动勾画全部危及器官需88.5分钟。

局限性

  • 原文未报告局限性。
英文原文(摘要)· 点击展开

Radiother Oncol. 2022 Aug;173:262-268. doi: 10.1016/j.radonc.2022.06.004. Epub 2022 Jun 15. ABSTRACT BACKGROUND AND PURPOSE: During radiotherapy treatment planning, avoidance of organs at risk (OARs) is important. An international consensus-based delineation guideline was recently published with 34 OARs in the brain. We developed an MR-based OAR autosegmentation atlas and evaluated its performance compared to manual delineation. MATERIALS AND METHODS: Anonymized cerebral T1-weighted MR scans (voxel size 0.9 × 0.9 × 0.9 mm 3 ) were available. OARs were manually delineated according to international consensus. Fifty MR scans were used to develop the autosegmentation atlas in a commercially available treatment planning system (Raystation®). The performance of this atlas was tested on another 40 MR scans by automatically delineating 34 OARs, as defined by the 2018 EPTN consensus. Spatial overlap between manual and automated delineations was determined by calculating the Dice similarity coefficient (DSC). Two radiation oncologists determined the quality of each automatically delineated OAR. The time needed to delineate all OARs manually or to adjust automatically delineated OARs was determined. RESULTS: DSC was ≥ 0.75 in 31 (91 %) out of 34 automated OAR delineations. Delineations were rated by radiation oncologists as excellent or good in 29 (85 %) out 34 OAR delineations, while 4 were rated fair (12 %) and 1 was rated poor (3 %). Interobserver agreement between the radiation oncologists ranged from 77-100 % per OAR. The time to manually delineate all OARs was 88.5 minutes, while the time needed to adjust automatically delineated OARs was 15.8 minutes. CONCLUSION: Autosegmentation of OARs enables high-quality contouring within a limited time. Accurate OAR delineation helps to define OAR constraints to mitigate serious complications and helps with the development of NTCP models. PMID: 35714807 | DOI: 10.1016/j.radonc.2022.06.004

来源:指南共识 · 神经影像,查看原文。版权归原作者所有。

引用

  1. 指南共识 · 神经影像:Development and evaluation of an automated EPTN-consensus based organ at risk atlas in the brain on MRI

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。