文献速递头颈MR

优化扫描参数以缩短基于RESOLVE的鼻咽癌扩散峰度成像(DKI)采集时间

Optimization of scan parameters to reduce acquisition time for RESOLVE-based diffusion kurtosis imaging (DKI) in nasopharyngeal carcinoma (NPC).
PubMed 文献 · Br J Radiol · 2022-06-22

前瞻性纳入38例鼻咽癌患者,比较5/8部分傅里叶(RPF)与无RPF的RESOLVE-DKI图像质量,并模拟9组不同b值组合。无RPF组信噪比和对比噪声比高于5/8 RPF组但无显著差异;采用RPF联合b值优化(200、400、800、2000 s/mm²)较无RPF全b值组合(200、400、800、1500、2000 s/mm²)扫描时间缩短56%(3分46秒 vs 8分31秒)。

要点

  • 5/8 RPF与无RPF的DKI图像信噪比和对比噪声比无显著差异。
  • b值组合(200、800、2000 s/mm²)等三组与全b值组ICC一致性极好(0.81-1.00)。
  • RPF联合b值优化可将扫描时间从8分31秒缩短至3分46秒,降低56%。

核心结论

  • RPF技术对DKI图像质量无显著影响,RPF联合b值优化可在保证DKI参数稳定性的同时将扫描时间缩短56%。

研究设计与样本

  • 前瞻性纳入38例鼻咽癌患者,比较5/8 RPF与无RPF的RESOLVE-DKI图像质量,并模拟9组不同b值组合,采用组内相关系数(ICC)评估b值组合的影响。

诊断标准与关键数值

  • 无RPF组信噪比252.9±77.7 vs 5/8 RPF组247.3±85.5,差异无统计学意义(p=0.460)。
  • 无RPF组对比噪声比5.8±2.8 vs 5/8 RPF组5.4±2.3,差异无统计学意义(p=0.180)。
  • b值组合(200、800、2000 s/mm²)、(200、400、800、2000 s/mm²)和(200、800、1500、2000 s/mm²)与(200、400、800、1500、2000 s/mm²)组间ICC无显著差异(p>0.001),一致性极好(ICC 0.81-1.00)。

临床应用与阅片要点

  • 采用5/8 RPF联合b值组合(200、400、800、2000 s/mm²)可在不显著影响图像质量的前提下将RESOLVE-DKI扫描时间从8分31秒缩短至3分46秒。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: To shorten acquisition time of readout segmentation of long variable echo trains (RESOLVE)-based diffusion kurtosis imaging (DKI) via Readout Partial Fourier (RPF) and b-value combinations.

METHODS: The RESOLVE-based DKI images of 38 patients with nasopharyngeal carcinoma (NPC) were prospectively enrolled. For RESOLVE-based DKI images with 5/8 RPF and without RPF, objective and subjective evaluations of image quality were performed. A total of nine groups with different b-value combinations were simulated, and the influence of different b-value combinations for RESOLVE-RPF-based DKI sequences was assessed using the intraclass correlation coefficient (ICC).

RESULTS: The mean values of signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) in DKI images without RPF were higher than those with 5/8 RPF (252.9 ± 77.7 vs 247.3 ± 85.5 and 5.8 ± 2.8 vs 5.4 ± 2.3, respectively), but not significantly (p = 0.460 and p = 0.180, respectively). In comparing the ICCs between nine groups of different b-value combinations in RESOLVE-RPF-based DKI, group (200, 800, 2000 s/mm2), group (200, 400, 800, 2000 s/mm2) and group (200, 800, 1500, 2000 s/mm2) were not significantly different (p > 0.001) and showed excellent agreement (0.81-1.00) with that of group (200, 400, 800, 1500, 2000 s/mm2). Using b-value optimization and RPF technology, the group with RPF (200, 400, 800, 2000 s/mm2) showed a 56% reduced scanning compared with the group without RPF (200, 400, 800, 1500, 2000 s/mm2; 3 min 46 s vs 8 min 31 s, respectively).

CONCLUSION: DKI with RPF did not significantly affect image quality, but both RPF and different b-value combinations can affect the scanning time. The combination of RPF and b-value optimization can ensure the stability of DKI parameters and reduce the scanning time by 56%.

ADVANCES IN KNOWLEDGE: This work is to optimize scan parameters, e.g. RPF and b-value combinations, to reduce acquisition time for RESOLVE-based DKI in NPC. To our knowledge, the effect of RESOLVE-RPF and b-value combinations on DKI has not been reported.

来源:Br J Radiol,查看原文。版权归原作者所有。

引用

  1. He, Chen, Zhang, et al. Optimization of scan parameters to reduce acquisition time for RESOLVE-based diffusion kurtosis imaging (DKI) in nasopharyngeal carcinoma (NPC). Br J Radiol. 2022. PMID: 35704453. doi:10.1259/bjr.20210641

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。