锡预滤过超低剂量光子计数CT鼻窦成像:剂量能低到什么程度?
研究在5具尸体头颅上比较光子计数探测器CT与能量积分探测器CT行锡预滤过鼻窦超低剂量扫描,按面中部外伤、术前鼻腔鼻窦解剖和急性鼻窦炎三类临床场景确定最具剂量效益的方案,PCD-CT所需辐射剂量均低于EID-CT;0.08与0.10 mGy的超低剂量PCD-CT虽噪声更高,仍被认为适合以炎症为目标的成像,读者间主观图像质量一致性极佳(ICC 0.90)。
要点
- 面中部外伤诊断最具剂量效益的方案为PCD-CT 1.24 mGy,EID-CT需2.05 mGy。
- 术前鼻腔鼻窦解剖评估为PCD-CT 0.20 mGy,EID-CT需0.40 mGy。
- 急性鼻窦炎为PCD-CT 0.08 mGy,EID-CT需0.15 mGy,PCD-CT剂量均更低(P<0.050)。
核心结论
- 在锡预滤过鼻窦成像中,PCD-CT图像质量优于高端EID-CT,0.08 mGy的超低辐射剂量即被认为足以评估鼻窦,提示临床常规(如鼻窦炎诊断检查)存在大幅降低剂量的潜力。
研究设计与样本
- 采用5具尸体头颅,在两种CT系统标准分辨率扫描模式下以100 kV管电压和锡预滤过扫描7个剂量等效方案(CTDI vol=4.16-0.15 mGy)及2个仅PCD-CT可实现的超低剂量方案(0.10和0.08 mGy),经可比迭代重建后由4名放射科医生主观评估图像质量,并以标准化感兴趣区定量图像噪声。
关键影像表现/征象
- 超低剂量PCD-CT(0.08和0.10 mGy)图像噪声更高,但仍被认为适合以炎症为目标的成像。
- 超低剂量PCD-CT较EID-CT检查的剂量代价更低。
诊断标准与关键数值
- 面中部外伤最具剂量效益方案:PCD-CT 1.24 mGy,EID-CT 2.05 mGy。
- 术前鼻腔鼻窦解剖最具剂量效益方案:PCD-CT 0.20 mGy,EID-CT 0.40 mGy。
- 急性鼻窦炎最具剂量效益方案:PCD-CT 0.08 mGy,EID-CT 0.15 mGy。
- 主观图像质量读者间一致性ICC为0.90(95%CI 0.88-0.93,P<0.001)。
临床应用与阅片要点
- 作者认为0.08 mGy超低辐射剂量评估鼻窦即已足够,提示临床常规(如鼻窦炎诊断检查)有大幅降低剂量的潜力。
局限性
- 研究基于5具尸体头颅,非在体患者。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVES: In this study, we compared photon-counting detector computed tomography (PCD-CT) and energy-integrating detector computed tomography (EID-CT) for ultra-low-dose paranasal sinus examinations with employed tin prefiltration. The goal of our investigation was to define the most dose-effective scan protocols for diagnostic assessment of midface trauma, preoperative sinonasal anatomy, and acute rhinosinusitis.
MATERIALS AND METHODS: Five cadaveric heads were examined with the standard-resolution scan mode of both CT systems using a tube potential of 100 kV and tin prefiltration for 7 dose-equivalent scan protocols (CTDI vol = 4.16-0.15 mGy) and 2 additional ultra-low-dose protocols exclusively feasible on the PCD-CT scanner (0.10 and 0.08 mGy). After applying comparable iterative reconstruction algorithms, image quality was subjectively assessed by 4 radiologists. The intraclass correlation coefficient was calculated to estimate the agreement among readers. Image noise was quantified in standardized regions of interest to establish an additional quantitative criterion of image quality.
RESULTS: The most dose-effective scan protocols for diagnostic imaging of midface trauma (PCD-CT: 1.24 mGy; EID-CT: 2.05 mGy), preoperative sinonasal anatomy (PCD-CT: 0.20 mGy; EID-CT: 0.40 mGy), and acute rhinosinusitis (PCD-CT: 0.08 mGy; EID-CT: 0.15 mGy) required less radiation exposure on the PCD-CT system ( P < 0.050). Despite higher image noise, ultra-low-dose PCD-CT studies (0.08 and 0.10 mGy) were considered suitable for inflammation-focused imaging, offering lower-dose penalties than EID-CT studies. Interobserver reliability for subjective image quality was excellent (intraclass correlation coefficient, 0.90; 95% confidence interval, 0.88-0.93; P < 0.001).
CONCLUSIONS: In paranasal sinus imaging with tin prefiltration, the PCD-CT allowed for superior image quality compared with high-end EID-CT. Assessment of paranasal sinuses with an ultra-low radiation exposure of 0.08 mGy was deemed adequate, suggesting substantial dose reduction potential for clinical routine, for example, in the diagnostic workup of patients with rhinosinusitis.
引用
- Grunz, Petritsch, Luetkens, et al. Ultra-Low-Dose Photon-Counting CT Imaging of the Paranasal Sinus With Tin Prefiltration: How Low Can We Go? Invest Radiol. 2022. PMID: 35703452. doi:10.1097/RLI.0000000000000887
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。