文献速递神经外周血管CTDSA

薄层CT图像迭代重建与最大密度投影显示血栓

Visualization of thrombus using iterative reconstruction and maximum intensity projection of thin-slice CT images.
PubMed 文献 · Neuroradiology · 2022-06-16

本研究纳入29例大脑梗死伴大血管闭塞患者,比较常规0.5mm薄层CT、薄层CT最大密度投影(MIP)及迭代重建(IR)联合MIP三种图像对血栓的显示效果。IR+MIP组噪声标准差更低、对比噪声比更高,图像评价更优;三位专家评估血栓边缘坐标无观察者间差异,视觉评估及与DSA机械取栓结果比较在IR+MIP组统计学更优。

要点

  • IR+MIP组噪声标准差更低、对比噪声比更高,图像评价更优。
  • 三位专家识别血栓边缘坐标无观察者间差异。
  • IR+MIP组视觉评估及与DSA比较统计学更优。

核心结论

  • 迭代重建降低噪声并提高分辨率,最大密度投影联合迭代重建有助于显示血栓。

研究设计与样本

  • 研究纳入29例大脑梗死伴大血管闭塞患者,每例重建三种图像并分为三组。
  • 常规组评估0.5mm层厚CT,MIP组评估0.5mm层厚CT经MIP处理,IR+MIP组评估0.5mm层厚CT经IR和MIP处理。
  • 以噪声标准差和对比噪声比评估噪声与图像质量,三位专家评估血栓边缘坐标并行视觉评估,与机械取栓的DSA比较。

关键影像表现/征象

  • IR+MIP组噪声标准差更低、对比噪声比统计学更高,图像评价更有利。
  • 血栓评估中血栓边缘识别无观察者间差异。
  • IR+MIP组视觉评估及与DSA比较统计学更优。

局限性

  • 原文未报告局限性

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: Iterative reconstruction (IR) is a noise reduction method that facilitates the synthesis of maximum intensity projection (MIP) from a larger number of slices while maintaining resolution. The present study aimed to analyze whether CT evaluation using IR and MIP is ideal for thrombus evaluation of large vessel occlusions in patients with acute ischemic stroke.

METHODS: Three types of images for each patient were reconstructed and categorized into three groups: the "conventional group," evaluated using 0.5-mm slice CT, the "MIP group," evaluated using 0.5-mm slice CT processed with MIP, and the "IR + MIP group," evaluated with 0.5-mm slice CT processed with IR and MIP. Noise and image quality were evaluated with noise standard deviation (Noise SD) and contrast-to-noise ratio (CNR). Three experts evaluated the thrombus edge coordinates, made a visual assessment, and compared the data with the digital subtraction angiography (DSA) of the mechanical thrombectomy.

RESULTS: Twenty-nine patients with cerebral infarction having large vessel occlusion were included in this study. The IR + MIP group had a lower Noise SD and a statistically higher CNR, leading to more favorable image evaluations. The thrombus assessment showed no inter-rater variability in thrombus edge identification, and the visual assessment and comparison with DSA were statistically better in the IR + MIP group.

CONCLUSIONS: IR reduces noise and improves resolution. MIP in combination with IR facilitates visualization of thrombus.

来源:Neuroradiology,查看原文。版权归原作者所有。

引用

  1. Kobayashi, Morizumi, Okumura, et al. Visualization of thrombus using iterative reconstruction and maximum intensity projection of thin-slice CT images. Neuroradiology. 2022. PMID: 35705738. doi:10.1007/s00234-022-02996-9

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。