文献速递乳腺技术与安全乳腺X线

基于可解释深度学习模型评估标准乳腺摄影模体图像,实现X线乳腺摄影扫描仪的可靠质量控制

Reliable quality assurance of X-ray mammography scanner by evaluation the standard mammography phantom image using an interpretable deep learning model.
PubMed 文献 · Eur J Radiol · 2022-05-23

研究收集来自1755家机构的2208幅乳腺摄影模体图像,开发并验证一种串联两个深度学习网络的可解释模型,用于客观评估模体图像质量。模型在模体检测和模体对象检测中表现出高准确率,对象评分在排除模糊点后组内共识达97.40%,模糊点组共识为59.10%,成功验证了模体图像质量管理的可靠性和可行性。

要点

  • 可解释深度学习模型可客观评估乳腺摄影模体图像质量,辅助放射科医生阅片。
  • 模体检测准确率1.00,mIOU 0.938;模体对象检测准确率0.995,mIOU 0.813。
  • 对象评分在排除模糊点后组内共识97.40%,模糊点组共识59.10%。

核心结论

  • 使用多中心大规模数据的可解释深度学习模型表现出高性能和合理的对象评分,成功验证了乳腺摄影模体图像质量管理的可靠性和可行性。

研究设计与样本

  • 研究收集来自1755家机构的2208幅乳腺摄影模体图像用于扫描仪周期性认证,随机分为训练集1808幅和测试集400幅,并设76幅图像的子组用于多阅片者研究;模型为串联两个深度学习网络,包含模体检测、模体对象检测、后处理、评分评估和模糊结果注释报告五个处理步骤。

关键影像表现/征象

  • 模体检测在测试集的准确率为1.00,平均交并比(mIOU)为0.938。
  • 模体对象检测中6400个对象有6369个被检测为正确对象类别,准确率0.995,mIOU 0.813。
  • 每个对象的预测评分在排除模糊点后组内共识为97.40%,模糊点组共识为59.10%。

诊断标准与关键数值

  • 模体检测准确率1.00、mIOU 0.938(测试集)。
  • 模体对象检测准确率0.995、mIOU 0.813(6400个对象中6369个正确分类)。
  • 对象评分组内共识:排除模糊点97.40%,模糊点59.10%。

临床应用与阅片要点

  • 该可解释深度学习模型可辅助放射科医生客观评估乳腺摄影模体图像质量,用于扫描仪周期性认证的质量控制。
  • 模型对模糊结果会生成注释报告,提示阅片者关注评分不确定的对象。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: Mammography is the initial examination to detect breast cancer symptoms, and quality control of mammography devices is crucial to maintain accurate diagnosis and to safeguard against degradation of performance. The objective of this study was to assist radiologists in mammography phantom image evaluation by developing and validating an interpretable deep learning model capable of objectively evaluating the quality of standard phantom images for mammography.

MATERIALS AND METHODS: A total of 2,208 mammography phantom images were collected for periodic accreditation of the scanner from 1,755 institutions. The dataset was randomly split into training (1,808 images) and testing (400 images) datasets with subgroups (76 images) for the multi-reader study. To develop an interpretable model that contains two deep learning networks in series, five processing steps were performed: mammography phantom detection, phantom object detection, post-processing, score evaluation, and a report with a comment about ambiguous results.

RESULTS: For phantom detection, the accuracy and mean intersection over union (mIOU) were 1.00 and 0.938 in the test dataset, respectively. During phantom object detection, a total of 6,369 out of 6,400 objects were detected as the correct object class, and the accuracy and mIOU were 0.995 and 0.813, respectively. The predicted score for each object showed a consensus of 97.40% excluding ambiguous points and 59.10% for ambiguous points of the groups.

CONCLUSIONS: The interpretable deep learning model using large-scale data from multiple centers shows high performance and reasonable object scoring, successfully validating the reliability and feasibility of mammography phantom image quality management.

来源:Eur J Radiol,查看原文。版权归原作者所有。

引用

  1. Oh, Kim, Lee, et al. Reliable quality assurance of X-ray mammography scanner by evaluation the standard mammography phantom image using an interpretable deep learning model. Eur J Radiol. 2022. PMID: 35691109. doi:10.1016/j.ejrad.2022.110369

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。