文献速递骨肌CT

使用光子计数探测器CT对肩关节和骨盆进行超高分辨率成像:患者可行性研究

Ultra-high-resolution imaging of the shoulder and pelvis using photon-counting-detector CT: a feasibility study in patients.
PubMed 文献 · Eur Radiol · 2022-06-11

前瞻性纳入32例(17例肩关节、15例骨盆)患者,比较研究性光子计数探测器CT的超高分辨率模式与能量积分探测器CT。光子计数探测器CT在解剖结构显示上评分显著更优(p<0.001),骨CT值显著更高(p<0.001),图像噪声无显著差异,辐射剂量降低31%–47%。

要点

  • 光子计数探测器CT在肩关节和骨盆骨性结构显示上显著优于能量积分探测器CT(p<0.001)。
  • 肩关节骨小梁显示平均评分4.24±0.73,骨盆髋臼股骨关节显示平均评分3.67±1.03,为各部位最高分。
  • 光子计数探测器CT骨CT值显著高于能量积分探测器CT(p<0.001),图像噪声两者无显著差异。

核心结论

  • 所评估的光子计数探测器CT系统在肩关节和骨盆骨性结构显示上优于能量积分探测器CT,辐射剂量降低31%–47%。

研究设计与样本

  • 前瞻性可行性研究,纳入32例(17例肩关节、15例骨盆)接受临床肩关节或骨盆能量积分探测器CT检查的患者,同时使用光子计数探测器CT系统超高分辨率模式扫描。

关键影像表现/征象

  • 肩关节骨小梁显示平均评分4.24±0.73,为肩关节各解剖结构中最高分。
  • 骨盆髋臼股骨关节显示平均评分3.67±1.03,为骨盆各解剖结构中最高分。
  • 光子计数探测器CT骨CT值较能量积分探测器CT显著增高(p<0.001)。
  • 光子计数探测器CT与能量积分探测器CT图像噪声无显著差异。

诊断标准与关键数值

  • 两位肌骨放射科医师采用5点Likert量表对解剖结构显示进行评分,光子计数探测器CT评分显著优于能量积分探测器CT(p<0.001)。
  • 图像重建:能量积分探测器CT轴位图像层厚1 mm、Br62/Br64卷积核;光子计数探测器CT图像层厚0.6 mm、Br76卷积核。
  • 体型特异性剂量评估:肩关节光子计数探测器CT平均容积CT剂量指数18 mGy vs 能量积分探测器CT 34 mGy;骨盆光子计数探测器CT 11.6 mGy vs 能量积分探测器CT 16.7 mGy,光子计数探测器CT剂量降低31%–47%。

临床应用与阅片要点

  • 光子计数探测器CT探测器像素尺寸为0.151 mm×0.176 mm(等中心),支持肩关节和骨盆的双侧高分辨率成像。
  • 两位肌骨放射科医师评分显示,尽管光子计数探测器CT辐射剂量较能量积分探测器CT降低31%–47%,其解剖结构显示仍优于能量积分探测器CT。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: To evaluate ultra-high-resolution (UHR) imaging of large joints using an investigational photon-counting detector (PCD) CT.

MATERIALS AND METHODS: Patients undergoing clinical shoulder or pelvis energy-integrating-detector (EID) CT exam were scanned using the UHR mode of the PCD-CT system. Axial EID-CT images (1-mm sections) and PCD-CT images (0.6-mm sections) were reconstructed using Br62/Br64 and Br76 kernels, respectively. Two musculoskeletal radiologists rated visualization of anatomic structures using a 5-point Likert scale. Wilcoxon rank-sum test was used for statistical analysis of reader scores, and paired t-test was used for comparing bone CT numbers and image noise from PCD-CT and EID-CT.

RESULTS: Thirty-two patients (17 shoulders and 15 pelvis) were prospectively recruited for this feasibility study. Mean age for shoulder exams was 67.3 ± 15.5 years (11 females) and 47.2 ± 15.8 years (11 females) for pelvis exams. The mean volume CT dose index was lower on PCD-CT compared to that on EID-CT (shoulders: 18 mGy vs. 34 mGy, pelvis: 11.6 mGy vs. 16.7 mGy). PCD-CT was rated significantly better than EID-CT (p < 0.001) for anatomic-structure visualization. Trabecular delineation in shoulders (mean score = 4.24 ± 0.73) and femoroacetabular joint visualization in the pelvis (mean score = 3.67 ± 1.03) received the highest scores. PCD-CT demonstrated significant increase in bone CT number (p < 0.001) relative to EID-CT; no significant difference in image noise was found between PCD-CT and EID-CT.

CONCLUSION: The evaluated PCD-CT system provided improved visualization of osseous structures in the shoulders and pelvises at a 31-47% lower radiation dose compared to EID-CT.

KEY POINTS: • A full field-of-view PCD-CT with 0.151 mm × 0.176 mm detector pixel size (isocenter) facilitates bilateral, high-resolution imaging of shoulders and pelvis. • The evaluated investigational PCD-CT system was rated superior by two musculoskeletal radiologists for anatomic structure visualization in shoulders and pelvises despite a 31-47% lower radiation dose compared to EID-CT. • PCD-CT demonstrated significantly higher bone CT number compared to EID-CT, while no significant difference in image noise was observed between PCD-CT and EID-CT despite a 31-47% dose reduction on PCD-CT.

来源:Eur Radiol,查看原文。版权归原作者所有。

引用

  1. Baffour, Rajendran, Glazebrook, et al. Ultra-high-resolution imaging of the shoulder and pelvis using photon-counting-detector CT: a feasibility study in patients. Eur Radiol. 2022. PMID: 35689699. doi:10.1007/s00330-022-08925-x

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。