比较三种k空间数据采集方式获得的三维MRCP在IPMN患者中应用深度学习重建的价值
回顾性纳入32例IPMN患者,比较并行成像、Fast 3Dm和压缩感知联合并行成像三种3D MRCP在有无深度学习重建下的采集时间、图像质量及IPMN分布评估准确性;Fast 3Dm和压缩感知联合并行成像采集时间显著短于并行成像,深度学习重建显著提高SNR和CNR,并行成像(有无深度学习重建)及Fast 3Dm联合深度学习重建的IPMN分布准确性显著更高。
要点
- Fast 3Dm和压缩感知联合并行成像的采集时间显著短于并行成像。
- 深度学习重建可显著提高各序列的SNR和CNR。
- 并行成像(有无深度学习重建)及Fast 3Dm联合深度学习重建的IPMN分布准确性显著更高。
核心结论
- 深度学习重建有助于提高并行成像、Fast 3Dm或压缩感知联合并行成像所得3D MRCP的图像质量和IPMN评估能力;Fast 3Dm和压缩感知联合并行成像可能作为并行成像的替代用于IPMN患者MRCP。
研究设计与样本
- 回顾性纳入32例IPMN患者,均行并行成像、Fast 3Dm和压缩感知联合并行成像三种3D MRCP,并分别在有和无深度学习重建下重建;以超声内镜、ERCP、手术或病理检查结果为标准参考。
诊断标准与关键数值
- 并行成像有深度学习重建与无深度学习重建的IPMN分布准确性均为88.0%,二者均显著高于其他方案(p<0.05)。
- Fast 3Dm联合深度学习重建的IPMN分布准确性为86.0%,显著高于其他方案(p<0.05)。
- 各MRCP序列联合深度学习重建的SNR和CNR均显著高于未联合深度学习重建者(p<0.05)。
- Fast 3Dm和压缩感知联合并行成像(有无深度学习重建)的采集时间均显著短于并行成像(有无深度学习重建)(p<0.05)。
临床应用与阅片要点
- 深度学习重建可用于并行成像、Fast 3Dm或压缩感知联合并行成像所得3D MRCP以提高图像质量和IPMN评估能力。
- Fast 3Dm和压缩感知联合并行成像可能作为并行成像的替代用于IPMN患者MRCP。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVE: To compare the utility of deep learning reconstruction (DLR) for improving acquisition time, image quality, and intraductal papillary mucinous neoplasm (IPMN) evaluation for 3D MRCP obtained with parallel imaging (PI), multiple k-space data acquisition for each repetition time (TR) technique (Fast 3D mode multiple: Fast 3Dm) and compressed sensing (CS) with PI.
MATERIALS AND METHODS: A total of 32 IPMN patients who had undergone 3D MRCPs obtained with PI, Fast 3Dm, and CS with PI and reconstructed with and without DLR were retrospectively included in this study. Acquisition time, signal-to-noise ratio (SNR), and contrast-to-noise ratio (CNR) obtained with all protocols were compared using Tukey's HSD test. Results of endoscopic ultrasound, ERCP, surgery, or pathological examination were determined as standard reference, and distribution classifications were compared among all 3D MRCP protocols by McNemar's test.
RESULTS: Acquisition times of Fast 3Dm and CS with PI with and without DLR were significantly shorter than those of PI with and without DLR (p < 0.05). Each MRCP sequence with DLR showed significantly higher SNRs and CNRs than those without DLR (p < 0.05). IPMN distribution accuracy of PI with and without DLR and Fast 3Dm with DLR was significantly higher than that of Fast 3Dm without DLR and CS with PI without DLR (p < 0.05).
CONCLUSION: DLR is useful for improving image quality and IPMN evaluation capability on 3D MRCP obtained with PI, Fast 3Dm, or CS with PI. Moreover, Fast 3Dm and CS with PI may play as substitution to PI for MRCP in patients with IPMN.
KEY POINTS: • Mean examination times of multiple k-space data acquisitions for each TR and compressed sensing with parallel imaging were significantly shorter than that of parallel imaging (p < 0.0001). • When comparing image quality of 3D MRCPs with and without deep learning reconstruction, deep learning reconstruction significantly improved signal-to-noise ratio and contrast-to-noise ratio (p < 0.05). • IPMN distribution accuracies of parallel imaging with and without deep learning reconstruction (with vs. without: 88.0% vs. 88.0%) and multiple k-space data acquisitions for each TR with deep learning reconstruction (86.0%) were significantly higher than those of others (p < 0.05).