基于多参数MRI的影像组学特征用于术前预测鼻腔鼻窦恶性肿瘤Ki-67增殖状态:一项双中心研究
该双中心回顾性研究纳入128例鼻腔鼻窦恶性肿瘤患者,利用多参数MRI影像组学特征构建逻辑回归模型预测Ki-67高增殖状态,其中联合序列模型在测试集上AUC为0.852(0.733-0.971)、准确率86.3%,提示影像组学可能作为无创工具用于术前评估Ki-67增殖状态。
要点
- 基于多参数MRI(T1WI、FS-T2WI、T1c)的联合影像组学模型在测试集预测Ki-67高增殖的AUC为0.852,准确率86.3%。
- 临床资料和常规MRI表现未发现Ki-67高增殖的独立预测因素。
- 联合模型较单参数模型在校准曲线和决策曲线分析中显示更好的拟合度和临床获益。
核心结论
- 基于多参数MRI的影像组学特征可能作为无创、可靠且准确的工具,用于术前评估鼻腔鼻窦恶性肿瘤的Ki-67增殖状态,以克服采样偏倚。
研究设计与样本
- 双中心回顾性分析,共纳入128例接受多参数MRI的鼻腔鼻窦恶性肿瘤患者;一个中心数据(n=77)用于开发预测模型,另一个中心数据(n=51)作为测试集。
诊断标准与关键数值
- 基于单参数MRI构建了RS-T1、RS-T2和RS-T1c(增强T1WI)影像组学特征。
- 影像组学特征通过最大相关最小冗余(mRMR)和最小绝对收缩和选择算子(LASSO)算法筛选,并使用逻辑回归(LR)算法建立模型。
临床应用与阅片要点
- 原文未据此给出推荐。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVE: To assess the predictive ability of a multi-parametric MRI-based radiomics signature (RS) for the preoperative evaluation of Ki-67 proliferation status in sinonasal malignancies.
METHODS: A total of 128 patients with sinonasal malignancies that underwent multi-parametric MRIs at two medical centres were retrospectively analysed. Data from one medical centre (n = 77) were used to develop the predictive models and data from the other medical centre (n = 51) constitute the test dataset. Clinical data and conventional MRI findings were reviewed to identify significant predictors. Radiomics features were determined using maximum relevance minimum redundancy and least absolute shrinkage and selection operator algorithms. Subsequently, RSs were established using a logistic regression (LR) algorithm. The predictive performance of RSs was assessed using calibration, decision curve analysis (DCA), accuracy, and AUC.
RESULTS: No independent predictors of high Ki-67 proliferation were observed based on clinical data and conventional MRI findings. RS-T1, RS-T2, and RS-T1c (contrast enhancement T1WI) were established based on a single-parametric MRI. RS-Combined (combining T1WI, FS-T2WI, and T1c features) was developed based on multi-parametric MRI and achieved an AUC and accuracy of 0.852 (0.733-0.971) and 86.3%, respectively, on the test dataset. The calibration curve and DCA demonstrated an improved fitness and benefits in clinical practice.
CONCLUSIONS: A multi-parametric MRI-based RS may be used as a non-invasive, dependable, and accurate tool for preoperative evaluation of the Ki-67 proliferation status to overcome the sampling bias in sinonasal malignancies.
KEY POINTS: • Multi-parametric MRI-based radiomics signatures (RSs) are used to preoperatively evaluate the proliferation status of Ki-67 in sinonasal malignancies. • Radiomics features are determined using maximum relevance minimum redundancy (mRMR) and least absolute shrinkage and selection operator (LASSO) algorithms. • RSs are established using a logistic regression (LR) algorithm.
引用
- Bi, Li, Wang, et al. Multi-parametric MRI-based radiomics signature for preoperative prediction of Ki-67 proliferation status in sinonasal malignancies: a two-centre study. Eur Radiol. 2022. PMID: 35687135. doi:10.1007/s00330-022-08780-w
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。