文献速递神经外周血管CT

基于RAPID CT灌注的相对CBF识别前循环卒中良好侧支状态优于低灌注强度比、CBV指数和达峰时间

RAPID CT Perfusion-Based Relative CBF Identifies Good Collateral Status Better Than Hypoperfusion Intensity Ratio, CBV-Index, and Time-to-Maximum in Anterior Circulation Stroke.
PubMed 文献 · AJNR Am J Neuroradiol · 2022-06-09

回顾性分析214例急性前循环缺血性卒中(MCA M1段或颈动脉末端闭塞)患者,用RAPID软件计算CT灌注参数,以动态CTA多时相CTA评分≥4定义为良好侧支。相对CBF<38%且病灶体积<27mL识别良好侧支的敏感度75%、特异度80%,优于低灌注强度比、CBV指数和达峰时间。

要点

  • 相对CBF<38%且病灶体积<27mL识别良好侧支的敏感度75%、特异度80%。
  • 相对CBF<38%体积与侧支评分的相关性最高(ρ=-0.66,P<.001)。
  • 低灌注强度比<0.4、CBV指数>0.8、达峰时间>8秒的识别效能均低于相对CBF。

核心结论

  • 自动CT灌注分析可准确识别急性缺血性卒中的侧支状态,相对CBF<38%可能是优于达峰时间、低灌注强度比和CBV指数的良好侧支灌注指标。

研究设计与样本

  • 回顾性研究,纳入214例因MCA M1段或颈动脉末端闭塞的急性缺血性卒中患者,侧支状态用动态CTA按Menon等多时相CTA评分评估,CT灌注参数(达峰时间、相对CBF、低灌注强度比、CBV指数)用RAPID软件评估。

诊断标准与关键数值

  • 良好侧支定义为侧支评分≥4;相对CBF<38%且病灶体积<27mL识别良好侧支的敏感度75%、特异度80%,与侧支评分相关性ρ=-0.66(P<.001);低灌注强度比<0.4敏感度75%、特异度62%;CBV指数>0.8敏感度60%、特异度78%;达峰时间>8秒敏感度68%、特异度76%。

临床应用与阅片要点

  • 作者认为相对CBF<38%可能是优于达峰时间、低灌注强度比和CBV指数的良好侧支灌注指标。

局限性

  • 原文未报告局限性

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

BACKGROUND AND PURPOSE: Information of collateral flow may help to determine eligibility for thrombectomy. Our aim was to identify CT perfusion-based surrogate parameters of good collateral status in acute anterior circulation ischemic stroke.

MATERIALS AND METHODS: In this retrospective study, we assessed the collateral status of 214 patients who presented with acute ischemic stroke due to occlusion of the MCA M1 segment or the carotid terminus. Collaterals were assessed on dynamic CTA images analogous to the multiphase CTA score by Menon et al. CT perfusion parameters (time-to-maximum, relative CBF, hypoperfusion intensity ratio, and CBV-index) were assessed with RAPID software. The Spearman rank correlation and receiver operating characteristic analyses were performed to identify the parameters that correlate with collateral scores and good collateral supply (defined as a collateral score of ≥4).

RESULTS: The Spearman rank correlation was highest for a relative CBF < 38% volume (ρ = -0.66, P < .001), followed by the hypoperfusion intensity ratio (ρ = -0.49, P < .001), CBV-index (ρ = 0.51, P < .001), and time-to-maximum > 8 seconds (ρ = -0.54, P < .001). Good collateral status was better identified by a relative CBF < 38% at a lesion size <27 mL (sensitivity of 75%, specificity of 80%) compared with a hypoperfusion intensity ratio of <0.4 (sensitivity of 75%, specificity of 62%), CBV-index of >0.8 (sensitivity of 60%, specificity of 78%), and time-to-maximum > 8 seconds (sensitivity of 68%, specificity of 76%).

CONCLUSIONS: Automated CT perfusion analysis allows accurate identification of collateral status in acute ischemic stroke. A relative CBF < 38% may be a better perfusion-based indicator of good collateral supply compared with time-to-maximum, the hypoperfusion intensity ratio, and the CBV-index.

来源:AJNR Am J Neuroradiol,查看原文。版权归原作者所有。

引用

  1. Potreck, Scheidecker, Weyland, et al. RAPID CT Perfusion-Based Relative CBF Identifies Good Collateral Status Better Than Hypoperfusion Intensity Ratio, CBV-Index, and Time-to-Maximum in Anterior Circulation Stroke. AJNR Am J Neuroradiol. 2022. PMID: 35680162. doi:10.3174/ajnr.A7542

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。