文献速递头颈儿科影像US

基于超声评估儿童腭扁桃体肥大的新方法:一项初步研究

A New Approach for Evaluating Palatine Tonsillar Hypertrophy in Children Based on Ultrasound: A Pilot Study.
PubMed 文献 · J Ultrasound Med · 2022-06-07

本研究回顾性分析172例2–14岁儿童扁桃体超声,提出颏下斜横断面新切面并计算(T1+T2)/O比值;该比值诊断扁桃体肥大的AUC为0.970,最佳截断值2.293时敏感度88.2%、特异度95.4%。

要点

  • 新切面「颏下斜横断面」测量左、右扁桃体径线T1、T2及口咽中央径线O,计算比值(T1+T2)/O。
  • 比值诊断扁桃体肥大的AUC为0.970,优于扁桃体体积的AUC 0.835。
  • 比值最佳截断值2.293,敏感度88.2%、特异度95.4%。

核心结论

  • 建立颏下斜横断面超声新切面及(T1+T2)/O比值,可客观评估儿童腭扁桃体肥大,该比值与年龄、BMI无线性相关。

研究设计与样本

  • 回顾性分析172例2–14岁儿童扁桃体超声,其中扁桃体肥大85例、非肥大87例,记录性别、年龄、BMI及超声测量的扁桃体体积。

关键影像表现/征象

  • 在颏下斜横断面测量左扁桃体径线T1、右扁桃体径线T2及口咽中央径线O。
  • 非肥大组双侧扁桃体体积与年龄或BMI呈正线性相关。
  • 比值与年龄或BMI无线性相关。

诊断标准与关键数值

  • 比值诊断扁桃体肥大的AUC为0.970(95%CI:0.947–0.993)。
  • 扁桃体体积诊断扁桃体肥大的AUC为0.835(95%CI:0.778–0.893)。
  • 比值最佳截断值为2.293,敏感度88.2%、特异度95.4%。

临床应用与阅片要点

  • 作者认为该切面易于获取,可提供参考值以指导临床实践。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: To develop a novel ultrasound (US) plane to diagnose palatine tonsillar hypertrophy objectively in children.

METHODS: Tonsillar ultrasonography of children (age 2-14 years) who had a clinical diagnosis of tonsillar hypertrophy or not were analyzed retrospectively. Clinical data (including gender, age, body mass index (BMI)), and volume (V) of tonsils measured by the US, were recorded. Furthermore, we found a new US plane to diagnose tonsillar hypertrophy and named it the submental oblique cross-section. In this plane, diameters of the left tonsil, right tonsil, and central oropharynx were designated as T1, T2, and O. Then, we calculated the ratio by the formula (T1 + T2)/O.

RESULTS: A total of 172 cases (85 hypertrophy and 87 non-hypertrophy) were included in this study. There were no significant differences in gender (P = .844), age (P = .666), and BMI (P = .089) between the groups. In the non-hypertrophy group, the V of both sides had a positive linear correlation with age or BMI. In contrast, there was no linear correlation between ratio and age or BMI. The area under the curve (AUC) of ratio and V was 0.970 (95%CI: 0.947-0.993) and 0.835 (95%CI: 0.778-0.893) by receiver operating characteristic (ROC) analysis, respectively. The optimal cutoff value of ratio for diagnosis of tonsillar hypertrophy was 2.293 (sensitivity = 88.2%, specificity = 95.4%).

CONCLUSIONS: We established a new US section to evaluate tonsillar hypertrophy. This approach could be easily acquired and provide a reference value to guide clinical practice.

来源:J Ultrasound Med,查看原文。版权归原作者所有。

引用

  1. Geng, Tian, Song, et al. A New Approach for Evaluating Palatine Tonsillar Hypertrophy in Children Based on Ultrasound: A Pilot Study. J Ultrasound Med. 2022. PMID: 35670148. doi:10.1002/jum.16030

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。