声触诊剪切波弹性成像评估病灶周围组织硬度在乳腺恶性病变诊断中的价值
单中心纳入90例乳腺肿块女性,用常规超声与声触诊剪切波弹性成像测量肿块及周围0.5–2.0 mm环带组织弹性值,并与病理对照。Emax-shell-2.0诊断恶性AUC最高为0.930,敏感度87.5%、特异度88%,且与恶性组胶原纤维含量高度相关(r=0.877)。
要点
- Emax-shell-2.0诊断乳腺恶性肿块的AUC为0.930,敏感度87.5%、特异度88%。
- Emax-shell-2.0与年龄为恶性独立预测因子。
- 恶性组Emax-shell-2.0与周围组织胶原纤维含量高度相关(r=0.877)。
核心结论
- 声触诊剪切波弹性成像测量病灶周围组织硬度可通过反映胶原纤维含量识别乳腺恶性肿块,其中Emax-shell-2.0表现最佳。
研究设计与样本
- 经机构伦理委员会批准的单中心研究,2020年12月至2021年7月纳入90例经常规超声和声触诊剪切波弹性成像检查的乳腺肿块女性,以组织病理学为参考标准。
诊断标准与关键数值
- Emax-shell-2.0诊断乳腺恶性肿块的AUC为0.930,敏感度87.5%,特异度88%。
临床应用与阅片要点
- 作者认为声触诊剪切波弹性成像测量病灶周围组织硬度是识别乳腺恶性肿块的有用指标,Emax-shell-2.0表现最佳。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
The aim of the study described here was to assess the evaluation of tissue stiffness around lesions by sound touch shear wave elastography (STE) in breast malignancy diagnosis. This was an institutional ethics committee-approved, single-center study. A total of 90 women with breast masses examined with conventional ultrasound and STE were eligible for enrollment from December 2020 to July 2021. The maximum and mean elastic values of masses, Emax and Emean, were determined. Shell function was used to measure the maximum and mean elastic values of tissues around masses in annular shells 0.5, 1.0, 1.5 and 2.0 mm wide, recorded as corresponding Emax-shell and Emean-shell. All parameters were analyzed and compared with histopathologic results. Receiver operating characteristic curves were constructed to assess diagnostic performance. Logistic regression analysis was conducted to determine the best diagnostic model. Collagen fiber content of tissues around breast lesions was evaluated using Masson staining and ImageJ software. Ninety women with breast masses were included in this study; 50 had benign (mean diameter 15.84 ± 4.39 mm) and 40 had malignant (mean diameter 17.40 ± 5.42 mm) masses. The diagnostic value of Emax-shell-2.0 was the highest (area under the curve = 0.930) with a sensitivity of 87.5% and specificity of 88%. According to stepwise logistic regression analysis, Emax-shell-2.0 and age were independent predictors of malignancy. Emax-shell-2.0 was also found to be highly correlated with the collagen fiber content of tissue in the malignant group (r = 0.877). Tissue stiffness around lesions measured by STE is a useful metric in identifying malignant breast masses by reflecting collagen fiber content, and Emax-shell-2.0 performs best.
引用
- Cui, He, Ye, et al. Evaluation of Tissue Stiffness Around Lesions by Sound Touch Shear Wave Elastography in Breast Malignancy Diagnosis. Ultrasound Med Biol. 2022. PMID: 35672199. doi:10.1016/j.ultrasmedbio.2022.04.219
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。