基于磁共振成像的影像组学与机器学习分析评估肝脏黏液性结直肠癌转移
本研究回顾性纳入病理证实的结直肠癌肝转移患者,训练集121例、外部验证集30例,从T2W SPACE序列提取851个影像组学特征,采用单变量分析、线性回归模型和模式识别方法进行分类;单变量分析最佳准确率为92%,15个显著特征的线性回归模型准确率94%、敏感度92%、特异度95%,KNN分类器精度低于最佳线性回归模型;作者结论认为影像组学指标有助于黏液亚型病灶的 characterization。
要点
- T2W SPACE序列提取的影像组学特征可用于鉴别肝脏黏液性结直肠癌转移。
- 15个显著特征的线性回归模型准确率94%、敏感度92%、特异度95%。
- KNN分类器精度低于最佳线性回归模型。
核心结论
- 影像组学指标有助于黏液亚型病灶的 characterization,以实现更个体化的方法。
- 作者证明T2W序列提取的纹理指标获得最佳性能。
研究设计与样本
- 回顾性研究,训练集121例、外部验证集30例,均为病理证实的结直肠癌肝转移且行MRI检查。
- 由两名专家放射科医生手动分割感兴趣体积,使用PyRadiomics工具提取851个影像组学特征的中位值。
- 采用单变量分析、线性回归建模和模式识别方法作为统计与分类程序。
诊断标准与关键数值
- 单变量分析最佳结果为T2W SPACE序列提取的wavelet_LLH_glcm_JointEntropy,准确率92%。
- 15个显著特征的线性回归模型准确率94%、敏感度92%、特异度95%。
- 测试的模式识别方法中最佳分类器为k-最近邻(KNN),但KNN精度低于最佳线性回归模型。
临床应用与阅片要点
- 原文未据此给出推荐。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
PURPOSE: The purpose of this study is to evaluate the Radiomics and Machine Learning Analysis based on MRI in the assessment of Liver Mucinous Colorectal Metastases.Query METHODS: The cohort of patients included a training set (121 cases) and an external validation set (30 cases) with colorectal liver metastases with pathological proof and MRI study enrolled in this approved study retrospectively. About 851 radiomics features were extracted as median values by means of the PyRadiomics tool on volume on interest segmented manually by two expert radiologists. Univariate analysis, linear regression modelling and pattern recognition methods were used as statistical and classification procedures.
RESULTS: The best results at univariate analysis were reached by the wavelet_LLH_glcm_JointEntropy extracted by T2W SPACE sequence with accuracy of 92%. Linear regression model increased the performance obtained respect to the univariate analysis. The best results were obtained by a linear regression model of 15 significant features extracted by the T2W SPACE sequence with accuracy of 94%, a sensitivity of 92% and a specificity of 95%. The best classifier among the tested pattern recognition approaches was k-nearest neighbours (KNN); however, KNN achieved lower precision than the best linear regression model.
CONCLUSIONS: Radiomics metrics allow the mucinous subtype lesion characterization, in order to obtain a more personalized approach. We demonstrated that the best performance was obtained by T2-W extracted textural metrics.
引用
- Granata, Fusco, De Muzio, et al. Radiomics and machine learning analysis based on magnetic resonance imaging in the assessment of liver mucinous colorectal metastases. Radiol Med. 2022. PMID: 35653011. doi:10.1007/s11547-022-01501-9