肩袖术后影像学:系统综述与Meta分析
本系统综述与Meta分析评估MRI与超声诊断肩袖修复术后再撕裂的准确性,纳入8项研究共304例患者309个肩关节,以手术所见为参考标准。全层再撕裂诊断中,MRI敏感度85.9%、特异度89.1%,超声敏感度89.7%、特异度91.0%,两者敏感度与特异度均无显著差异(p=.28-.76)。
要点
- MRI与超声诊断肩袖修复术后再撕裂的敏感度和特异度无显著差异(p=.28-.76)。
- 全层再撕裂:MRI敏感度85.9%、特异度89.1%;超声敏感度89.7%、特异度91.0%。
- MRI或超声均可考虑作为评估疑似肩袖再撕裂的一线影像选择。
核心结论
- 分析显示超声与MRI诊断肩袖修复术后肌腱再撕裂无显著差异。
- MRI或超声均可考虑作为评估疑似肩袖修复术后再撕裂的一线影像选择。
研究设计与样本
- 系统综述与Meta分析,纳入8项原始研究(MRI n=6,超声 n=2),共304例患者(MRI n=221,超声 n=83)、309个肩关节(MRI n=226,超声 n=83)。
- 纳入标准为以手术所见为参考标准、评估MRI(含非增强MRI与MR关节造影)和超声诊断肩袖修复术后再撕裂准确性的原始研究。
- 采用QUADAS-2评估方法学质量;MRI研究发表年份1993至2006年,超声研究发表年份2003至2018年。
- 2项研究因患者选择在临床适用性方面存在高偏倚风险;5项研究在2个领域存在潜在偏倚风险,2项研究在3个领域存在潜在偏倚风险。
- 采用Cochran Q检验和I²统计量分析研究间变异。
诊断标准与关键数值
- 全部再撕裂:MRI敏感度81.4%(95%CI 73.3-87.5%)、特异度82.6%(95%CI 76.3-87.5%);超声敏感度83.7%(95%CI 67.4-92.7%)、特异度90.7%(95%CI 73.6-97.1%)。
- 全层再撕裂:MRI敏感度85.9%(95%CI 80.2-90.2%)、特异度89.1%(95%CI 84.6-92.4%);超声敏感度89.7%(95%CI 75.6-96.1%)、特异度91.0%(95%CI 75.5-97.1%)。
- 全部再撕裂与全层再撕裂的敏感度和特异度比较均无显著差异(p=.28-.76)。
临床应用与阅片要点
- MRI或超声均可考虑作为评估疑似肩袖修复术后再撕裂的一线影像选择。
局限性
- 2项研究因患者选择在临床适用性方面存在高偏倚风险。
- 5项研究在2个领域存在潜在偏倚风险,2项研究在3个领域存在潜在偏倚风险。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
BACKGROUND. It is unclear which, MRI or ultrasound (US), is the most useful imaging tool to diagnose rotator cuff retears. OBJECTIVE. The objective of this study was to evaluate MRI and US in terms of diagnosing retear of a repaired rotator cuff tendon using a systematic review and meta-analysis. EVIDENCE ACQUISITION. A comprehensive literature search was performed on the main concepts of MRI (including noncontrast MRI and MR arthrography), US, and rotator cuff repairs. Inclusion criteria consisted of original research studies that assessed the diagnostic accuracy of MRI and US (index tests) for the diagnosis of rotator cuff tendon retear after prior rotator cuff repair using surgical findings as the reference standard. QUADAS-2 was used to assess methodologic quality. Meta-analyses were performed to compare MRI and US studies in the diagnosis of all retears and of full-thickness retears. Study variation was analyzed using the Cochran Q test and I2 statistic. EVIDENCE SYNTHESIS. Eight studies (MRI, n = 6; US, n = 2) satisfied inclusion and exclusion criteria, consisting of 304 total patients (MRI, n = 221; US, n = 83) and 309 shoulders (MRI, n = 226; US, n = 83). Years of publication ranged from 1993 to 2006 for the MRI studies and from 2003 to 2018 for the US studies. Two studies had high risk of bias in terms of applicability to clinical practice because of patient selection. Five studies had potential risk of bias in two categories, whereas two had potential risk of bias in three categories. For all retears, mean sensitivity and specificity for MRI were 81.4% (95% CI, 73.3-87.5%) and 82.6% (95% CI, 76.3-87.5%) and 83.7% (95% CI, 67.4-92.7%) and 90.7% (95% CI, 73.6-97.1%) for US. For full-thickness retears, mean sensitivity and specificity for MRI were 85.9% (95% CI, 80.2-90.2%) and 89.1% (95% CI, 84.6-92.4%) and 89.7% (95% CI, 75.6-96.1%) and 91.0% (95% CI, 75.5-97.1%) for US. There was no significant difference in terms of sensitivity or specificity for either comparison (p = .28-.76). CONCLUSION. Our analyses revealed no significant difference between US and MRI for the diagnosis of rotator cuff tendon tears after prior cuff repair. CLINICAL IMPACT. Either MRI or US can be considered a first-line imaging option to assess suspected rotator cuff retear after prior repair.
引用
- Gyftopoulos, Cardoso, Rodrigues, et al. Postoperative Imaging of the Rotator Cuff: A Systematic Review and Meta-Analysis. AJR Am J Roentgenol. 2022. PMID: 35642759. doi:10.2214/AJR.22.27847
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。