文献速递胸部技术与安全CT

光子计数探测器CT在系统性硬化症患者间质性肺病评估中降低辐射剂量的潜力

Potential of Photon-Counting Detector CT for Radiation Dose Reduction for the Assessment of Interstitial Lung Disease in Patients With Systemic Sclerosis.
PubMed 文献 · Invest Radiol · 2022-05-28

回顾性纳入80例系统性硬化症患者,比较光子计数探测器CT(PCD-CT)与能量积分探测器CT(EID-CT)不同剂量水平对间质性肺病的评估。PCD-CT的CTDI vol与EID-CT 33%剂量相当(0.72 vs 0.76 mGy),图像噪声与100%剂量相当,主观图像质量与100%剂量相当(4.72 vs 4.71),诊断准确率97.6%高于33%和66%剂量(92.5%/96.3%),与100%剂量(98.1%)相当。结论认为PCD-CT相比EID-CT可降低66%辐射剂量而不损失图像质量和诊断性能。

要点

  • PCD-CT在CTDI vol 0.72 mGy下图像噪声和主观质量与EID-CT 100%剂量相当。
  • PCD-CT诊断准确率97.6%,高于EID-CT 33%剂量(92.5%)和66%剂量(96.3%)。
  • PCD-CT诊断准确率与EID-CT 100%剂量(98.1%)相当,支持66%辐射剂量降低。

核心结论

  • PCD-CT相比EID-CT可实现66%的辐射剂量降低,而不损失图像质量和间质性肺病诊断性能。

研究设计与样本

  • 回顾性研究,纳入2021年5月至2021年12月间接受PCD-CT随访非增强胸部检查的系统性硬化症患者80例(平均56±14岁;64例女性)。基线扫描在双源EID-CT上通过选择2个X射线管的管电流-时间乘积,从同一数据集生成100%(D100)、66%(D66)和33%(D33)剂量图像,两次扫描间调整层厚和卷积核。以22年经验放射科医生判读的D100为参考标准。

诊断标准与关键数值

  • PCD-CT的CTDI vol与D33相当(0.72 vs 0.76 mGy,P=0.091);PCD-CT平均图像噪声与D100相当(131±15 vs 113±12,P>0.05);PCD-CT总体主观图像质量与D100相当(4.72 vs 4.71,P=0.874);诊断准确率PCD-CT为97.6%,D33为92.5%,D66为96.3%,D100为98.1%。

临床应用与阅片要点

  • 在系统性硬化症患者间质性肺病随访评估中,PCD-CT可在与EID-CT 33%剂量相当的辐射剂量下,获得与EID-CT 100%剂量相当的图像质量和诊断准确率。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: The aim of this study was to determine the potential of photon-counting detector computed tomography (PCD-CT) for radiation dose reduction compared with conventional energy-integrated detector CT (EID-CT) in the assessment of interstitial lung disease (ILD) in systemic sclerosis (SSc) patients.

METHODS: In this retrospective study, SSc patients receiving a follow-up noncontrast chest examination on a PCD-CT were included between May 2021 and December 2021. Baseline scans were generated on a dual-source EID-CT by selecting the tube current-time product for each of the 2 x-ray tubes to obtain a 100% (D 100 ), a 66% (D 66 ), and a 33% dose image (D 33 ) from the same data set. Slice thickness and kernel were adjusted between the 2 scans. Image noise was assessed by placing a fixed region of interest in the subcutaneous fat. Two independent readers rated subjective image quality (5-point Likert scale), presence, extent, diagnostic confidence, and accuracy of SSc-ILD. D 100 interpreted by a radiologist with 22 years of experience served as reference standard. Interobserver agreement was calculated with Cohen κ, and mean variables were compared by a paired t test.

RESULTS: Eighty patients (mean 56 ± 14; 64 women) were included. Although CTDI vol of PCD-CT was comparable to D 33 (0.72 vs 0.76 mGy, P = 0.091), mean image noise of PCD-CT was comparable to D 100 (131 ± 15 vs 113 ± 12, P > 0.05). Overall subjective image quality of PCD-CT was comparable to D 100 (4.72 vs 4.71; P = 0.874). Diagnostic accuracy was higher in PCD-CT compared with D 33 /D 66 (97.6% and 92.5%/96.3%, respectively) and comparable to D 100 (98.1%).

CONCLUSIONS: With PCD-CT, a radiation dose reduction of 66% compared with EID-CT is feasible, without penalty in image quality and diagnostic performance for the evaluation of ILD.

来源:Invest Radiol,查看原文。版权归原作者所有。

引用

  1. Jungblut, Euler, von Spiczak, et al. Potential of Photon-Counting Detector CT for Radiation Dose Reduction for the Assessment of Interstitial Lung Disease in Patients With Systemic Sclerosis. Invest Radiol. 2022. PMID: 35640003. doi:10.1097/RLI.0000000000000895

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。