文献速递泌尿生殖技术与安全US

三维经肛超声与四维经会阴超声诊断显著肛门外括约肌缺损标准的比较

Comparison of diagnostic criteria for significant anal sphincter defects between endoanal and transperineal ultrasound.
PubMed 文献 · Ultrasound Obstet Gynecol · 2022-11-10

本研究为PERINEAL研究的二次分析,对73名女性每周行三维经肛超声(EAUS)和四维经会阴超声(TPUS,静息及最大盆底肌收缩时)检查,共250次配对扫描。以EAUS为参考标准,TPUS诊断外括约肌缺损的κ=0.87、内括约肌缺损的κ=1.00,但测量缺损角度的标准误较大,若沿用30°阈值可导致约9-36%的外括约肌缺损和约4-15%的内括约肌缺损误诊。作者结论认为TPUS检查时不应使用30°阈值诊断显著残余肛门外括约肌缺损,需进一步研究确定TPUS的最佳缺损角度阈值。

要点

  • TPUS与EAUS诊断外括约肌缺损存在高度一致性(κ=0.87),诊断内括约肌缺损完全一致(κ=1.00)。
  • TPUS测量外括约肌缺损角度的标准误为±16.1°(静息)和±16.5°(最大收缩),测量内括约肌为±27.9°和±26.4°。
  • 以EAUS为参考,TPUS使用30°阈值可致约9-36%外括约肌和约4-15%内括约肌缺损误诊,作者认为TPUS不应使用30°阈值诊断显著残余缺损。

核心结论

  • 作者认为,TPUS检查时不应使用30°阈值诊断显著残余肛门外括约肌缺损,需进一步研究确定TPUS的最佳缺损角度阈值。

研究设计与样本

  • PERINEAL研究的二次分析;73名女性每周行EAUS与TPUS(静息及最大盆底肌收缩时)检查,直至会阴伤口愈合或最长16周,共250次EAUS和250次TPUS扫描;以EAUS为参考标准。

诊断标准与关键数值

  • 缺损角度>30°定义为显著缺损;TPUS诊断外括约肌缺损与EAUS的κ=0.87,诊断内括约肌缺损的κ=1.00;TPUS静息时测量外括约肌缺损角度的SEM为±16.1°、内括约肌为±27.9°,最大PFMC时外括约肌为±16.5°、内括约肌为±26.4°;以EAUS为参考,TPUS使用30°阈值可致约9-36%外括约肌和约4-15%内括约肌显著缺损误诊。

临床应用与阅片要点

  • 作者认为,TPUS检查时不应使用30°阈值诊断显著残余肛门外括约肌缺损;需进一步研究确定TPUS的最佳缺损角度阈值。

局限性

  • 需进一步研究确定TPUS的最佳缺损角度阈值。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: To evaluate the agreement between three-dimensional endoanal ultrasound (EAUS) and four-dimensional transperineal ultrasound (TPUS) in measuring anal sphincter defect angle.

METHODS: This was a secondary analysis of the PERINEAL study, which evaluated the effect of perineal wound infection on anal sphincter integrity. Women were reviewed once a week, until their perineal wound had healed or for up to a maximum of 16 weeks. At each visit, both EAUS and TPUS (the latter at rest and on maximum pelvic floor muscle contraction (PFMC)) were performed to evaluate the presence of external (EAS) and internal (IAS) anal sphincter defect and measure the defect size. The largest angle size of a defect at the same sphincter level was analyzed. A defect was deemed significant if it was > 30°. Kappa coefficient (κ), intraclass correlation coefficient and standard error of measurement (SEM) were calculated, using EAUS as the reference standard.

RESULTS: In 73 women scanned at weekly intervals, a total of 250 EAUS and 250 TPUS scans were performed. An EAS defect was found in 55 (22.0%) EAUS images and 47 (18.8%) TPUS images. An IAS defect was found in 26 (10.4%) images on both modalities. There was excellent agreement (κ = 0.87) between TPUS and EAUS in diagnosing the presence of an EAS defect and perfect agreement (κ = 1.00) in diagnosing the presence of an IAS defect. TPUS performed at rest had poor and moderate agreement with EAUS in measuring EAS and IAS defect size, respectively, with respective SEMs of ± 16.1° and ± 27.9°. TPUS performed during maximum PFMC had poor and moderate agreement with EAUS in measuring EAS and IAS defect size, respectively, with respective SEMs of ± 16.5° and ± 26.4°. Based on the SEMs, if the diagnostic cut-off of 30° for defect size on TPUS was used, an incorrect diagnosis of significant EAS defect could occur in approximately 9-36% of women and an incorrect diagnosis of a significant IAS defect could occur in approximately 4-15% of women, using EAUS as the reference.

CONCLUSIONS: This is the first study to compare directly anal sphincter defect angle measurements obtained on EAUS and TPUS. A cut-off angle of 30° should not be used for the diagnosis of a significant residual anal sphincter defect during TPUS examination. Further research is required to determine the optimal defect cut-off angle for TPUS. © 2022 The Authors. Ultrasound in Obstetrics & Gynecology published by John Wiley & Sons Ltd on behalf of International Society of Ultrasound in Obstetrics and Gynecology.

来源:Ultrasound Obstet Gynecol,查看原文。版权归原作者所有。

引用

  1. Okeahialam, Thakar, Sultan, et al. Comparison of diagnostic criteria for significant anal sphincter defects between endoanal and transperineal ultrasound. Ultrasound Obstet Gynecol. 2022. PMID: 35638253. doi:10.1002/uog.24957

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。