文献速递泌尿生殖妇产影像USMR

经阴道超声与MRI评估不孕女性卵巢体积和卵泡计数的比较研究

Using transvaginal ultrasonography and MRI to evaluate ovarian volume and follicle count of infertile women: a comparative study.
PubMed 文献 · Clin Radiol · 2022-05-28

研究纳入84例不孕女性,比较二维经阴道超声(2D TVUS)与2D/3D MRI测量卵巢体积(OV)和卵泡计数(FC)的差异。3D MRI测得的OV比2D TVUS小0.50 ml,但非常接近;2D MRI测得的OV比2D TVUS和3D MRI均明显偏小。2D TVUS低估了FC1-9 mm和总卵泡计数。作者认为,不适合TVUS的患者推荐用3D MRI评估OV;需要准确FC时,2D MRI是TVUS的有用替代。

要点

  • 3D MRI测得的卵巢体积比2D TVUS小0.50 ml,但两者非常接近。
  • 2D MRI测得的卵巢体积比2D TVUS小3.15 ml,明显低估。
  • 2D TVUS低估FC1-9 mm和总卵泡计数,且对1-3 mm卵泡计数偏低、4-6 mm偏高。

核心结论

  • 在不孕女性中,2D MRI测得的OV较2D TVUS低估;3D MRI测得的OV低于2D TVUS但非常接近,对不适合TVUS的患者推荐用3D MRI评估OV;2D TVUS较2D MRI低估FC1-9 mm和tFC,需要准确FC时2D MRI是TVUS的有用替代。

研究设计与样本

  • 比较研究,纳入84例不孕女性,分别用2D TVUS和2D/3D MRI评估卵巢体积和卵泡计数,采用Bland-Altman分析进行比较。

关键影像表现/征象

  • 3D MRI测得的OV比2D TVUS小0.50 ml(95%CI 0.25-0.74,p<0.001)。
  • 2D MRI测得的OV比3D MRI小2.65 ml(95%CI 2.36-2.95,p<0.001),比2D TVUS小3.15 ml(95%CI 2.77-3.53,p<0.001)。
  • 2D TVUS测得的FC1-9 mm比2D MRI小7.81(95%CI 6.96-8.66,p<0.001),tFC比2D MRI小7.82(95%CI 6.97-8.67)。
  • 2D TVUS检测的FC1-3 mm低于2D MRI,而FC4-6 mm高于2D MRI;FC7-9 mm和FC≥10 mm两组间无显著差异。

临床应用与阅片要点

  • 对不适合TVUS的患者,作者推荐用3D MRI评估卵巢体积。
  • 在生育咨询和研究中需要准确卵泡计数时,作者认为2D MRI是TVUS的有用替代。
  • 阅片时注意2D TVUS对1-3 mm卵泡计数偏低、对4-6 mm卵泡计数偏高,报告卵泡计数时需结合检查方法。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

AIM: To compare two-dimensional (2D) transvaginal ultrasonography (TVUS) and 2D/three-dimensional (3D) magnetic resonance imaging (MRI) in estimating ovarian volume and follicle count.

MATERIALS AND METHODS: The ovarian volume (OV) and follicle count (FC) of 84 women with infertility were evaluated by 2D TVUS and 2D/3D MRI. Bland-Altman analysis was used for comparison.

RESULTS: The OV from 3D MRI was 0.50 ml (95% confidence interval [CI], 0.25-0.74, p<0.001) smaller than that by 2D TVUS. OV from 2D MRI was 2.65 ml (95% CI, 2.36-2.95, p<0.001) and 3.15 ml (95% CI, 2.77-3.53, p<0.001) smaller than that from 3D MRI and 2D TVUS, respectively. The FC1-9 mm and total follicle count (tFC) estimated by 2D TVUS were 7.81 (95% CI, 6.96-8.66, p<0.001) and 7.82 (95% CI, 6.97-8.67) smaller than those from 2D MRI, respectively. Further analysis showed that 2D TVUS detected lower FC1-3 mm but higher FC4-6 mm than 2D MRI. No significant difference was shown in the results of FC7-9 mm and FC ≥ 10 mm.

CONCLUSION: In women with infertility, 2D MRI underestimated OV as compared with 2D TVUS. OV from 3D MRI was lower but very close to that from 2D TVUS. For patients unsuitable for TVUS, 3D MRI is recommended for OV evaluation. 2D TVUS underestimated FC1-9 mm and tFC compared with 2D MRI. In fertility counselling and research, 2D MRI is a useful alternative to TVUS when an accurate FC is needed.

来源:Clin Radiol,查看原文。版权归原作者所有。

引用

  1. Wang, Zhang, Duan, et al. Using transvaginal ultrasonography and MRI to evaluate ovarian volume and follicle count of infertile women: a comparative study. Clin Radiol. 2022. PMID: 35636975. doi:10.1016/j.crad.2022.04.016

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。