文献速递泌尿生殖MR

双参数与多参数MRI采用PI-RADS v2.1诊断外周带前列腺癌的比较

Comparison between biparametric and multiparametric MRI diagnosis strategy for prostate cancer in the peripheral zone using PI-RADS version 2.1.
PubMed 文献 · Abdom Radiol (NY) · 2022-05-27

本研究以穿刺活检和根治性前列腺切除为参考标准,PI-RADS评分≥4为阳性阈值,比较bpMRI与mpMRI、DWI与T2WI对外周带前列腺癌(pzPCa)及临床显著外周带前列腺癌(cs-pzPCa)的诊断效能。结果显示mpMRI与bpMRI、DWI与T2WI的诊断效能相似。

要点

  • mpMRI与bpMRI诊断pzPCa的AUC分别为0.717和0.733,差异无统计学意义(P=0.317)。
  • mpMRI与bpMRI诊断cs-pzPCa的AUC分别为0.594和0.602,差异无统计学意义(P=0.756)。
  • DWI与T2WI诊断pzPCa及cs-pzPCa的AUC差异均无统计学意义(P均>0.05)。

核心结论

  • 采用PI-RADS v2.1时,mpMRI与bpMRI以及DWI与T2WI对外周带前列腺癌和临床显著外周带前列腺癌的诊断效能相似。

研究设计与样本

  • 研究纳入307例前列腺病例,其中非外周带前列腺癌组142例、外周带前列腺癌组165例、临床显著外周带前列腺癌组130例;以PI-RADS评分≥4为阳性阈值,以前列腺穿刺活检和根治性前列腺切除为参考标准。

诊断标准与关键数值

  • mpMRI诊断pzPCa的AUC为0.717,敏感度89.1%,特异度54.2%。
  • bpMRI诊断pzPCa的AUC为0.733,敏感度81.8%,特异度64.8%。
  • mpMRI诊断cs-pzPCa的AUC为0.594,敏感度93.1%,特异度25.7%。
  • bpMRI诊断cs-pzPCa的AUC为0.602,敏感度86.2%,特异度34.3%。
  • DWI诊断pzPCa的AUC为0.733,敏感度81.8%,特异度64.8%;T2WI诊断pzPCa的AUC为0.749,敏感度84.2%,特异度66.2%。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: To compare and analyse the diagnostic value of PI-RADS v2.1 when used with biparametric MRI (bpMRI) versus multiparametric MRI (mpMRI), DWI versus T2WI to detect peripheral-zone prostate cancer (pzPCa) and clinically significant peripheral-zone prostate cancer (cs-pzPCa).

METHODS: The diagnostic efficiencies of mpMRI and bpMRI as well as DWI and T2WI in pzPCa and cs-pzPCa were compared using a PI-RADS score of ≥ 4 as the positive threshold and prostate biopsy and radical prostatectomy as the reference standards.

RESULTS: A total of 307 prostate cases were included in the study, including 142 in the non-pzPCa group, 165 in the pzPCa group, and 130 in the cs-pzPCa group. The AUCs of mpMRI and bpMRI were 0.717 and 0.733 (P = 0.317), respectively, for the diagnosis of pzPCa (sensitivities: 89.1% and 81.8%; specificities: 54.2% and 64.8%, both P < 0.001) and 0.594 and 0.602 (P = 0.756), respectively, for the diagnosis of cs-pzPCa (sensitivities: 93.1% and 86.2%, P = 0.004; specificities: 25.7% and 34.3%, P = 0.250). The AUCs of DWI and T2WI were 0.733 and 0.749 (P = 0.308), respectively, for the diagnosis of pzPCa (sensitivities: 81.8% and 84.2%; specificities: 64.8% and 66.2%, both P > 0.05) and 0.602 and 0.581 (P = 0.371), respectively, for the diagnosis of cs-pzPCa (sensitivities: 86.2% and 87.7%; specificities: 34.3% and 28.6%, both P > 0.05).

CONCLUSION: mpMRI and bpMRI as well as DWI and T2WI using PI-RADS v2.1 exhibited similar diagnostic efficiency in pzPCa and cs-pzPCa.

来源:Abdom Radiol (NY),查看原文。版权归原作者所有。

引用

  1. Zhang, Xu, Zhang, et al. Comparison between biparametric and multiparametric MRI diagnosis strategy for prostate cancer in the peripheral zone using PI-RADS version 2.1. Abdom Radiol (NY). 2022. PMID: 35622121. doi:10.1007/s00261-022-03553-x

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。