肝病患者定量超声与MRI的对比研究
前瞻性研究纳入44例8-21岁已知或疑似肝病且BMI<35 kg/m²的患者,同次就诊完成1.5-T MRI与定量超声检查。超声剪切波速度与MR弹性成像硬度呈正相关(r=0.73,P<.001),预测异常肝剪切硬度的AUC为0.95,敏感度91%、特异度95%;超声衰减预测异常PDFF的AUC为0.75。
要点
- 超声剪切波速度与MR弹性成像硬度呈正相关(r=0.73,P<.001)。
- 剪切波速度1.56 m/sec(7.3 kPa)阈值预测肝硬度>2.8 kPa的AUC为0.95。
- 超声衰减0.55 dB/cm/MHz阈值预测PDFF>5%的AUC为0.75。
核心结论
- 在已知或疑似肝病的儿童、青少年和年轻成人中,超声剪切波速度与MR弹性成像硬度呈中至高度相关,超声剪切波速度预测异常肝剪切硬度表现良好。
研究设计与样本
- 前瞻性研究,纳入连续患者44例(平均年龄16岁±4[SD],年龄范围8-21岁,男性23例),年龄8-21岁、已知或疑似肝病且BMI<35 kg/m²,于2018年4月至2020年12月在儿科学术医学中心同次就诊接受1.5-T MRI与定量肝脏超声检查;以MR弹性成像和MRI质子密度脂肪分数(PDFF)为参考标准。
诊断标准与关键数值
- 预测异常(>2.8 kPa)肝剪切硬度:剪切波速度(SWS)阈值1.56 m/sec(7.3 kPa),AUC 0.95,敏感度91%(95%CI:71,99)(20/22例),特异度95%(95%CI:76,99)(20/21例)。预测异常(>5%)肝脏PDFF:超声衰减阈值0.55 dB/cm/MHz,AUC 0.75,敏感度73%(95%CI:39,94)(8/11例),特异度73%(95%CI:55,86)(24/33例)。超声剪切波速度与MR弹性成像硬度正相关(r=0.73,P<.001);超声衰减与MRI PDFF正相关(r=0.45,P=.001)。
临床应用与阅片要点
- 作者结论认为,在已知或疑似肝病的儿童、青少年和年轻成人中,超声剪切波速度与MR弹性成像硬度呈中至高度相关。
- 作者结论认为,超声剪切波速度预测异常肝剪切硬度表现良好。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
Background Quantitative US techniques can be used to identify changes of liver disease, but data regarding their diagnostic performance and relationship to MRI measures are sparse. Purpose To define associations between quantitative US and MRI measures of the liver in children, adolescents, and young adults with liver disease and to define the predictive ability of quantitative US measures to detect abnormal liver stiffening and steatosis defined with MRI. Materials and Methods In this prospective study, consecutive patients aged 8-21 years and known to have or suspected of having liver disease and body mass index less than 35 kg/m2 underwent 1.5-T MRI and quantitative liver US during the same visit at a pediatric academic medical center between April 2018 and December 2020. Acquired US parameters included shear-wave speed (SWS) and attenuation coefficient, among others. US parameters were compared with liver MR elastography and liver MRI proton density fat fraction (PDFF). Pearson correlation, multiple logistic regression, and receiver operating characteristic curve analyses were performed to assess associations and determine the performance of US relative to that of MRI. Results A total of 44 study participants (mean age, 16 years ± 4 [SD]; age range, 8-21 years; 23 male participants) were evaluated. There was a positive correlation between US SWS and MR elastography stiffness (r = 0.73, P < .001). US attenuation was positively correlated with MRI PDFF (r = 0.45, P = .001). For the prediction of abnormal (>2.8 kPa) liver shear stiffness, SWS (1.56 m/sec [7.3 kPa] cutoff) had an area under the receiver operating characteristic curve (AUC) of 0.95 with 91% sensitivity (95% CI: 71, 99) (20 of 22 participants) and 95% specificity (95% CI: 76, 99) (20 of 21 participants). For the prediction of abnormal (>5%) liver PDFF, US attenuation (0.55 dB/cm/MHz cutoff) had an AUC of 0.75 with a sensitivity of 73% (95% CI: 39, 94) (eight of 11 participants) and a specificity of 73% (95% CI: 55, 86) (24 of 33 participants). Conclusion In children, adolescents, and young adults with known or suspected liver disease, there was moderate to high correlation between US shear-wave speed (SWS) and MR elastography-derived stiffness. US SWS predicted an abnormal liver shear stiffness with high performance. © RSNA, 2022 Online supplemental material is available for this article. See also the editorial by Khanna and Alazraki in this issue.