人工智能工具评估CT检出的不确定肺结节
回顾性多阅片者多病例研究评估人工智能计算机辅助诊断工具对12名阅片者(6名放射科医生、6名肺科医生)判读300例5-30mm不确定肺结节胸部CT的影响,结果显示CAD使平均AUC从0.82升至0.89,并改善恶性风险分层与处理建议的阅片者间一致性。
要点
- CAD使平均AUC从0.82升至0.89(P < .001),提升恶性风险评估判别能力。
- CAD使5%和65%恶性风险阈值下平均敏感度与特异度均提高,风险分层更准确。
- CAD改善恶性风险分类及处理建议(无处理、CT随访、诊断性操作)的阅片者间一致性。
核心结论
- 使用计算机辅助诊断可改善胸部CT上不确定肺结节恶性风险评估的判别能力,并提高风险分层与处理建议的阅片者间一致性。
研究设计与样本
- 回顾性多阅片者多病例研究,于2020年6月和7月进行,纳入300例最大径5-30 mm的不确定肺结节胸部CT(50.0%恶性),由12名阅片者(6名放射科医生、6名肺科医生)仅基于CT影像数据分别在无和有CAD时评估恶性风险并给出处理建议,患者中位年龄65岁(IQR 59-71岁),164名(55%)为男性。
关键影像表现/征象
- 原文未涉及具体影像征象描述
诊断标准与关键数值
- 阅片者平均AUC在使用CAD后从0.82提高至0.89(P < .001)。
- 在5%恶性风险阈值下,平均敏感度从94.1%提高至97.9%(P = .01),平均特异度从37.4%提高至42.3%(P = .03)。
- 在65%恶性风险阈值下,平均敏感度从52.6%提高至63.1%(P < .001),平均特异度从87.3%提高至89.9%(P = .05)。
- 恶性风险小于5%类别的阅片者间一致性Fleiss κ从0.50提高至0.71(P < .001),大于65%类别从0.54提高至0.71(P < .001)。
- 处理建议类别(无处理、CT随访、诊断性操作)的总体阅片者间一致性Fleiss κ从0.44提高至0.52(P = .001)。
临床应用与阅片要点
- 原文未据此给出推荐
局限性
- 原文未报告局限性
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
Background Limited data are available regarding whether computer-aided diagnosis (CAD) improves assessment of malignancy risk in indeterminate pulmonary nodules (IPNs). Purpose To evaluate the effect of an artificial intelligence-based CAD tool on clinician IPN diagnostic performance and agreement for both malignancy risk categories and management recommendations. Materials and Methods This was a retrospective multireader multicase study performed in June and July 2020 on chest CT studies of IPNs. Readers used only CT imaging data and provided an estimate of malignancy risk and a management recommendation for each case without and with CAD. The effect of CAD on average reader diagnostic performance was assessed using the Obuchowski-Rockette and Dorfman-Berbaum-Metz method to calculate estimates of area under the receiver operating characteristic curve (AUC), sensitivity, and specificity. Multirater Fleiss κ statistics were used to measure interobserver agreement for malignancy risk and management recommendations. Results A total of 300 chest CT scans of IPNs with maximal diameters of 5-30 mm (50.0% malignant) were reviewed by 12 readers (six radiologists, six pulmonologists) (patient median age, 65 years; IQR, 59-71 years; 164 [55%] men). Readers' average AUC improved from 0.82 to 0.89 with CAD (P < .001). At malignancy risk thresholds of 5% and 65%, use of CAD improved average sensitivity from 94.1% to 97.9% (P = .01) and from 52.6% to 63.1% (P < .001), respectively. Average reader specificity improved from 37.4% to 42.3% (P = .03) and from 87.3% to 89.9% (P = .05), respectively. Reader interobserver agreement improved with CAD for both the less than 5% (Fleiss κ, 0.50 vs 0.71; P < .001) and more than 65% (Fleiss κ, 0.54 vs 0.71; P < .001) malignancy risk categories. Overall reader interobserver agreement for management recommendation categories (no action, CT surveillance, diagnostic procedure) also improved with CAD (Fleiss κ, 0.44 vs 0.52; P = .001). Conclusion Use of computer-aided diagnosis improved estimation of indeterminate pulmonary nodule malignancy risk on chest CT scans and improved interobserver agreement for both risk stratification and management recommendations. © RSNA, 2022 Online supplemental material is available for this article. See also the editorial by Yanagawa in this issue.
引用
- Kim, Oke, Pickup, et al. Artificial Intelligence Tool for Assessment of Indeterminate Pulmonary Nodules Detected with CT. Radiology. 2022. PMID: 35608444. doi:10.1148/radiol.212182
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。