文献速递骨肌儿科影像DR

儿童骨折镁基生物可吸收螺钉吸收过程中的影像学特征

Radiographic features of magnesium-based bioabsorbable screw resorption in paediatric fractures.
PubMed 文献 · Pediatr Radiol · 2022-05-24

回顾性分析35例儿童骨折患者共103张X线片,评估镁螺钉固定后氢气在骨、骺板及软组织中的时空分布及螺钉或固定骨块断裂情况。骨内气体至第5周增加、第16周前保持恒定后减少,软组织内气体、关节内气体及关节积液随时间逐渐减少;螺钉断裂见于16/35(45.7%)患者,中位首次检出时间300天。

要点

  • 骨内和软组织内气泡是镁螺钉吸收过程中的正常表现,不应误判为软组织感染或骨髓炎。
  • 骺板内气体罕见,仅见于1/23(4.3%)骺板未闭合患者。
  • 固定骨块断裂见于4/35(11.4%)患者,均发生在最初6周内。

核心结论

  • 骨和软组织内气泡是螺钉吸收过程中的正常表现,不应与软组织感染或骨髓炎混淆;骺板内气体罕见;固定骨块和/或螺钉可发生断裂。

研究设计与样本

  • 回顾性研究,纳入35例接受镁螺钉治疗的儿童患者,共复习103张X线片,平均年龄10.6岁,随访时间1至730天。

关键影像表现/征象

  • 骨内气体至第5周增加,至第16周保持恒定,之后减少。
  • 软组织内气体、关节内气体及关节积液随时间逐渐减少。
  • 骺板未闭合患者中,1/23(4.3%)出现气体侵入骺板。
  • 固定骨块断裂见于4/35(11.4%)患者,均发生在最初6周内。
  • 螺钉断裂见于16/35(45.7%)患者,中位首次检出时间为300天。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

BACKGROUND: Resorption of magnesium-based alloy bioabsorbable screws produces hydrogen gas, which can be mistaken as a sign of infection and may affect the physis or fixed bone fragment.

OBJECTIVE: We evaluated the temporal and spatial occurrence of gas and the occurrence of a breakage of the fixed bone fragment or screw following magnesium screw fixation.

MATERIALS AND METHODS: Radiographs of paediatric patients treated with magnesium screws were retrospectively reviewed. Temporal occurrence and distribution of gas in the bone, the physis and soft tissues, breakage of the screw or fixed bone fragment and joint effusion were assessed.

RESULTS: One hundred and three radiographs in 35 paediatric patients were reviewed (mean age: 10.6 years). Follow-up ranged from 1 to 730 days. Gas in the bone increases up to week 5, remains constant up to week 16 and then decreases. Gas in soft tissues, intra-articular gas and joint effusions gradually reduce over time. In 1/23 (4.3%) patients with an open physis, gas intrusion into the physis occurred. Breakage of the bone fragment fixated by the screw was observed in 4/35 (11.4%) patients within the first 6 weeks. Screw breakage was observed in 16/35 (45.7%) patients, with a median time to first detection of 300 days.

CONCLUSION: Gas bubbles in bone and soft tissue are normal findings in the context of screw resorption and should not be confused with soft-tissue infection or osteomyelitis. Gas is rarely visible in the physis. Breakage of the fixed bone fragment and/or screw can occur.

来源:Pediatr Radiol,查看原文。版权归原作者所有。

引用

  1. Waelti, Markart, Willems, et al. Radiographic features of magnesium-based bioabsorbable screw resorption in paediatric fractures. Pediatr Radiol. 2022. PMID: 35606529. doi:10.1007/s00247-022-05383-x

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。