文献速递腹部介入MR

MR弹性成像可作为微波消融肝脏肿瘤的良好反应参数

MR elastography is a good response parameter for microwave ablation liver tumors.
PubMed 文献 · Eur J Radiol · 2022-05-14

研究51例肝肿瘤患者(肝细胞癌20例、转移瘤31例)在微波消融(MWA)术前及术后24小时行MRI与MR弹性成像,回顾性分析消融范围、T1/T2 mapping及硬度值。总肝硬度术后从3.31 kPa升至3.45 kPa(升高4.3%,p=0.036),且与消融时长相关(r=0.369,p=0.008);基线肿瘤硬度越高,所需消融能量越大(r=0.391,p<0.001)、时长越长(r=0.391,p=0.007)。作者认为MRE可用于评估治疗反应及 collateral 组织损伤,基线肿瘤硬度有助于确定合适的MWA参数。

要点

  • MWA术后24小时总肝硬度较小幅升高(3.31→3.45 kPa,升高4.3%,p=0.036),提示MRE可反映消融对周围肝组织的影响。
  • 基线肿瘤硬度越高,MWA所需能量越大(r=0.391,p<0.001)、消融时长越长(r=0.391,p=0.007),可用于术前预估消融参数。
  • 消融成功(边缘≥5 mm)者消融边缘硬度为5.3 kPa,未成功者为4.6 kPa,差异无统计学意义(p=0.26)。

核心结论

  • 作者认为,MWA术前及术后加做MRE可用于评估治疗反应及消融造成的周围组织损伤;基线肿瘤硬度有助于确定合适的MWA参数。

研究设计与样本

  • 回顾性分析51例肝肿瘤患者(男28例、女23例;肝细胞癌20例、转移瘤31例),在 percutaneous MWA术前及术后24小时行MRI和MR弹性成像,分析消融前后肿瘤范围、T1/T2 mapping、硬度值以及MWA session的时长和能量剂量。

关键影像表现/征象

  • 总肝硬度术后从3.31 kPa升至3.45 kPa,升高4.3%(p=0.036),与MWA session时长相关(r=0.369,p=0.008)。
  • 健康肝实质硬度从3.55 kPa升至3.68 kPa,升高3.5%(p=0.142),与累积能量(r=0.436,p<0.001)、时长(r=0.458,p<0.001)及能量强度(r=0.458,p<0.001)相关。
  • 基线肿瘤硬度越高,MWA所需能量越大(r=0.391,p<0.001),session时长越长(r=0.391,p=0.007)。
  • 43例技术成功(消融边缘≥5 mm)者消融边缘硬度为5.3 kPa,未成功者为4.6 kPa,差异无统计学意义(p=0.26)。
  • 技术成功者接受的消融强度为5.73 kJ/min,未成功者为5.03 kJ/min,差异有统计学意义(p=0.002)。

诊断标准与关键数值

  • 技术成功消融定义为消融边缘≥5 mm,51例中43例达到。
  • 总肝硬度术后升高4.3%(3.31 kPa vs 3.45 kPa,p=0.036)。
  • 健康肝实质硬度术后升高3.5%(3.55 kPa vs 3.68 kPa,p=0.142),差异无统计学意义。
  • 基线肿瘤硬度与MWA能量(r=0.391,p<0.001)及session时长(r=0.391,p=0.007)相关。
  • 技术成功者消融边缘硬度为5.3 kPa,未成功者为4.6 kPa(p=0.26),差异无统计学意义。

临床应用与阅片要点

  • 作者认为,MWA术前及术后可加做MRE以评估治疗反应及 collateral 组织损伤。
  • 作者认为,基线肿瘤硬度有助于确定合适的MWA参数。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: To determine the response of hepatic tissue to percutaneous microwave ablation (MWA) of liver tumors via MR elastography in a clinical setting using MRI and MR elastography.

METHODS: 51 Patients (28 m, 23f) underwent MWA of liver tumors (HCC: 20, metastasis: 31) and received MRI and MR elastography immediately before and 24 h after MWA. Retrospective analysis included pre- and post-ablative tumor extent, T1/T2 mapping and stiffness values as well as the duration and energy dose of the MWA session.

RESULTS: Total liver stiffness increased by 4.3% from 3.31 kPa to 3.45 kPa (p = 0.036). Total liver stiffness post-MWA significantly correlated with the duration of the MWA session (r = 0.369, p = 0.008). The higher the baseline tumor stiffness was, the more energy had to be applied in MWA (r = 0.391, p < 0.001) and the longer the duration of the session (r = 0.391, p = 0.007). Healthy parenchyma stiffness increased by 3.5% from 3.55 kPa to 3.68 kPa (p = 0.142) and was strongly influenced by the cumulative energy (r = 0.436, p < 0.001), the duration (r = 0.458, p < 0.001) and the energy intensity (r = 0.458, p < 0.001) of MWA. 43 patients had a technically successful ablation result (margin ≥ 5 mm). Those with successful ablation had increased ablation margin stiffness (5.3 kPa vs. 4.6 kPa, p = 0.26) and had received higher ablation intensity than those with unsuccessful ablation (5.73 kJ/min vs. 5.03 kJ/min, p = 0.002).

CONCLUSION: Additional MRE may be used before and after MWA to assess treatment response and collateral tissue damage after MWA. Baseline tumor stiffness helps finding the appropriate MWA parameters.

来源:Eur J Radiol,查看原文。版权归原作者所有。

引用

  1. Vogl, Dosch, Haas, et al. MR elastography is a good response parameter for microwave ablation liver tumors. Eur J Radiol. 2022. PMID: 35597071. doi:10.1016/j.ejrad.2022.110360

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。