深度学习重建对图像质量及冠状动脉CT血管造影衍生血流储备分数值的影响
本研究纳入33例已知或疑似冠心病患者的182个病灶,比较深度学习重建(DLR)与滤波反投影(FBP)、统计迭代重建(SBIR)、基于模型的迭代重建(MBIR)Cardiac及MBIR Cardiac sharp对冠状动脉CTA图像质量和基于机器学习的CT-FFR(CT-FFRML)值的影响。结果显示DLR图像质量优于其他方法,但不同重建方法间CT-FFRML值及诊断性能无显著差异。
要点
- DLR重建的冠状动脉CTA图像质量优于FBP、SBIR、MBIR Cardiac和MBIR Cardiac sharp。
- 五种重建方法的CT-FFRML值无显著差异(所有p>0.05)。
- 以有创FFR或QFR为参考时,不同重建方法的CT-FFRML诊断性能无显著差异(所有p>0.05)。
核心结论
- DLR算法提高了图像质量,但不同重建方法间的CT-FFRML值和诊断性能无显著差异。
研究设计与样本
- 连续纳入33例已知或疑似冠心病行冠状动脉CTA及后续有创冠状动脉造影的患者,比较DLR与FBP、SBIR、MBIR Cardiac、MBIR Cardiac sharp的图像质量,以有创FFR和QFR为参考标准计算不同重建方法的CT-FFRML诊断性能。
关键影像表现/征象
- DLR的图像质量优于其他重建方法。
诊断标准与关键数值
- 以有创FFR为参考时,MBIR Cardiac、MBIR Cardiac sharp和DLR的AUC均为0.82,FBP和AIDR的AUC均为0.78,所有p>0.05。
- 以QFR为参考时,FBP、SBIR、MBIR Cardiac、MBIR Cardiac sharp和DLR的AUC分别为0.83、0.81、0.86、0.84和0.83,所有p>0.05。
临床应用与阅片要点
- 原文未据此给出推荐。
局限性
- 182个病灶中仅17个有有创FFR结果,70个有QFR结果。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVES: To explore the impact of deep learning reconstruction (DLR) on image quality and machine learning-based coronary CT angiography (CTA)-derived fractional flow reserve (CT-FFRML) values.
METHODS: Thirty-three consecutive patients with known or suspected coronary artery disease who underwent coronary CTA and subsequent invasive coronary angiography were enrolled. DLR was compared with filtered back projection (FBP), statistical-based iterative reconstruction (SBIR), model-based iterative reconstruction (MBIR) Cardiac, and MBIR Cardiac sharp for objective image qualities of coronary CTA. Invasive fractional flow reserve (FFR) and quantitative flow ratio (QFR) were used as the reference standards. The diagnostic performances of different reconstruction approach-based CT-FFRML were calculated.
RESULTS: A total of 182 lesions in 33 patients were enrolled for analysis. The image quality of DLR was superior to the others. There were no significant differences in the CT-FFRML values among these five approaches (all p > 0.05). Of the 182 lesions, 17 had invasive FFR results, and 70 had QFR results. Using FFR as a reference, MBIR Cardiac, MBIR Cardiac sharp, and DLR achieved equal diagnostic performance, slightly higher than the other reconstruction approaches (MBIR Cardiac, MBIR Cardiac sharp, and DLR: AUC = 0.82, FBP and AIDR: AUC = 0.78, all p > 0.05). Using QFR as a reference, the AUCs of FBP, SBIR, MBIR Cardiac, MBIR Cardiac sharp, and DLR were 0.83, 0.81, 0.86, 0.84, and 0.83, respectively (all p > 0.05).
CONCLUSIONS: Our study showed that the DLR algorithm improved image quality, but there were no significant differences in the CT-FFRML values and diagnostic performance among different reconstruction approaches.
KEY POINTS: • Deep learning-based image reconstruction (DLR) improves the image quality of coronary CTA. • CT-FFRML values and diagnostic performance of DLR revealed no significant differences compared to other reconstruction approaches.
引用
- Xu, Xu, Yan, et al. The impact of deep learning reconstruction on image quality and coronary CT angiography-derived fractional flow reserve values. Eur Radiol. 2022. PMID: 35596780. doi:10.1007/s00330-022-08796-2
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。