文献速递外周血管技术与安全US

超快超声成像量化的颈动脉僵硬度个体化参考值:模型构建与初步验证

Individualized References of Carotid Stiffening Quantified With Ultrafast Ultrasound Imaging: Model Construction and Preliminary Validation.
PubMed 文献 · Ultrasound Med Biol · 2022-05-18

研究在建模队列225名健康人中建立基于年龄、低密度脂蛋白、收缩压和性别的颈动脉脉搏波速度-收缩末期估计方程,并在验证队列628人中分组验证。验证队列中低PWV-ES与高PWV-ES组间存在清晰分界,PWV-ES随年龄增长逐渐升高。该阈值方程诊断敏感度为78.9%、特异度为73.9%。

要点

  • 基于年龄、LDL、收缩压和性别构建的估计PWV-ES方程,在验证队列中敏感度78.9%、特异度73.9%。
  • 验证队列中实际PWV-ES≤估计值者为低PWV-ES组,>估计值者为高PWV-ES组,两组间存在清晰分界。
  • PWV-ES随年龄增长逐渐升高。

核心结论

  • 研究建立并验证了一种新的估计PWV-ES个体化参考方程,可能扩展前瞻性ufPWV评估的应用。

研究设计与样本

  • 建模队列纳入225名健康个体,验证队列纳入628名个体,均接受颈动脉内中膜厚度(cIMT)、收缩期开始脉搏波速度(PWV-BS)和收缩末期脉搏波速度(PWV-ES)评估;通过多元线性回归分析在建模队列获得估计PWV-ES阈值方程。

诊断标准与关键数值

  • 估计PWV-ES(m/s)= 0.080 × 年龄(岁)+ 0.767 × 低密度脂蛋白(mmol/L)+ 0.040 × 收缩压(mm Hg)+ 0.372 × 性别(男=1,女=0)- 2.803。
  • 验证队列以实际PWV-ES ≤ 估计PWV-ES为低PWV-ES组,实际PWV-ES > 估计PWV-ES为高PWV-ES组。
  • 阈值方程的敏感度为78.9%,特异度为73.9%。
  • 采用0.050 cm作为cIMT截断值将参与者分为cIMT亚组。

临床应用与阅片要点

  • 作者认为该个体化参考方程可能扩展前瞻性ufPWV评估的应用。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

To establish and preliminarily validate an individualized reference of carotid stiffness quantified by ultrafast pulse wave velocity (ufPWV), our study included 225 healthy individuals in the modeling cohort and 628 individuals in the validation cohort. All participants underwent assessment of carotid intima-media thickness (cIMT), pulse wave velocity-beginning of systole and pulse wave velocity-end of systole (PWV-ES). A threshold equation of estimated PWV-ES was obtained by multiple linear regression analysis in the modeling cohort as follows: estimated PWV-ES (m/s) = 0.080 × age (y) + 0.767 × low-density lipoprotein (mmol/L) + 0.040 × systolic blood pressure (mm Hg) + 0.372 × sex (male = 1, female = 0) - 2.803. With this equation, the validation cohort was divided into the low PWV-ES (actual PWV-ES ≤ estimated PWV-ES) and high PWV-ES (actual PWV-ES > estimated PWV-ES) groups. A clear boundary was found to be present between the low PWV-ES and high PWV-ES groups in the validation cohort. Participants with increasing PWV-ES increased with age gradually. We further subdivided participants into cIMT subgroups using a cutoff thickness of 0.050 cm. Diagnostic performance analysis revealed that the sensitivity and specificity of the threshold equation were 78.9% and 73.9%, respectively. We established and validated a novel individualized reference equation for estimated PWV-ES, which can likely expand the application of prospective ufPWV assessment.

来源:Ultrasound Med Biol,查看原文。版权归原作者所有。

引用

  1. Wang, Zhu, Ma, et al. Individualized References of Carotid Stiffening Quantified With Ultrafast Ultrasound Imaging: Model Construction and Preliminary Validation. Ultrasound Med Biol. 2022. PMID: 35595590. doi:10.1016/j.ultrasmedbio.2022.03.017

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。