文献速递腹部CT

肝细胞癌患者肝脏动态CT的CT容积测量与细胞外容积分数对肝纤维化预测能力的比较

Comparison between CT volumetry and extracellular volume fraction using liver dynamic CT for the predictive ability of liver fibrosis in patients with hepatocellular carcinoma.
PubMed 文献 · Eur Radiol · 2022-05-20

本研究回顾性分析90例连续接受肝切除术并完成CT容积测量和细胞外容积分数(ECV)计算的患者,比较手动、刚性配准和非刚性配准ECV与CT容积参数对肝纤维化的预测能力。结果显示SV/BSA在估计严重肝纤维化分级方面优于手动ECV,而手动ECV在高AUC(0.75)下可区分F0-3与F4。

要点

  • SV/BSA在区分F0-1 vs F2-4及F0-2 vs F3-4时AUC显著高于手动ECV。
  • SV/BSA的AUC(0.76-0.83)高于手动ECV(0.61-0.75),覆盖所有肝纤维化分级。
  • 手动ECV可区分F0-3与F4,AUC为0.75。

核心结论

  • 在接受肝切除术的患者中,SV/BSA是估计严重肝纤维化分级的更好方法,尽管手动ECV有能力估计肝硬化(≥F4)。

研究设计与样本

  • 回顾性分析90例连续接受肝切除术并完成CT容积测量和ECV计算的患者;ECV计算公式为ECV(%)=(1-血细胞比容)×(ΔHU肝脏/ΔHU主动脉),其中ΔHU为平衡期(240秒)减平扫期。

诊断标准与关键数值

  • 手动ECV、刚性配准ECV和非刚性配准ECV的AUC无显著差异;SV/BSA在F0-1 vs F2-4和F0-2 vs F3-4的AUC显著高于手动ECV;SV/BSA的AUC(0.76-0.83)高于手动ECV(0.61-0.75);手动ECV区分F0-3与F4的AUC为0.75。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: To compare the predictive ability of liver fibrosis (LF) by CT-volumetry (CTV) for liver and spleen and extracellular volume fraction (ECV) for liver in patients undergoing liver resection.

METHODS: We retrospectively analysed 90 consecutive patients who underwent CTV and ECV. Manually placed region-of-interest ECV (manual-ECV), rigid-registration ECV (rigid-ECV), and nonrigid-registration ECV (nonrigid-ECV) were calculated as ECV(%) = (1-haematocrit) × (ΔHUliver/ΔHUaorta), where ΔHU = subtraction of unenhanced phase from equilibrium phase (240 s). Manual-ECV was compared with CTV for the estimation of LF. The total liver volume to body surface area (TLV/BSA), splenic volume to BSA (SV/BSA), ratio of TLV to SV (TLV/SV), ratio of right liver volume to SV (RV/SV), and liver segmental volume ratio (LSVR) were measured. ROC analyses were performed for ECV and CTV.

RESULTS: After excluding 10 patients, seventy-eight (97.5%) out of 80 patients had a Child-Pugh score of 5 points, and two (2.5%) patients had a Child-Pugh score of 6 points. AUC of ECV showed no significant difference among manual-ECV, rigid-ECV, and nonrigid-ECV. TLV/BSA, SV/BSA, TLV/SV, and RV/SV had a higher correlation with LF grades than manual-ECV. AUC of SV/BSA was significantly higher than that of manual-ECV in F0-1 vs F2-4 and F0-2 vs F3-4. AUC of SV/BSA (0.76-0.83) was higher than that of manual-ECV (0.61-0.75) for all LF grades, although manual-ECV could differentiate between F0-3 and F4 at high AUC (0.75).

CONCLUSIONS: In patients undergoing liver resection, SV/BSA is a better method for estimating severe LF grades, although manual-ECV has the ability to estimate cirrhosis (≥ F4).

KEY POINTS: The splenic volume is a better method for estimating liver fibrosis grades. The extracellular volume fraction is also a candidate for the estimation of severe liver fibrosis.

来源:Eur Radiol,查看原文。版权归原作者所有。

引用

  1. Tago, Tsukada, Sudo, et al. Comparison between CT volumetry and extracellular volume fraction using liver dynamic CT for the predictive ability of liver fibrosis in patients with hepatocellular carcinoma. Eur Radiol. 2022. PMID: 35593960. doi:10.1007/s00330-022-08852-x

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。