文献速递妇产影像腹部MR

结合多参数MRI特征迁移学习与临床参数的机器学习用于鉴别子宫肉瘤与非典型子宫肌瘤

Combining multiparametric MRI features-based transfer learning and clinical parameters: application of machine learning for the differentiation of uterine sarcomas from atypical leiomyomas.
PubMed 文献 · Eur Radiol · 2022-05-18

本研究回顾性纳入86例子宫肉瘤与86例非典型子宫肌瘤,从T2WI和DWI提取迁移学习与影像组学特征,比较随机森林模型鉴别效能。测试集中迁移学习模型AUC均优于影像组学模型,联合临床参数与非增强mp-MRI特征的复杂多参数模型表现最佳,Resnet50模型AUC达0.96、准确率0.87。

要点

  • 迁移学习模型鉴别子宫肉瘤与非典型子宫肌瘤的AUC高于影像组学模型。
  • 联合临床参数与非增强mp-MRI特征的复杂多参数模型预测性能最佳。
  • Resnet50复杂多参数模型测试集AUC为0.96、准确率为0.87。

核心结论

  • 在本数据集上,迁移学习用于鉴别子宫肉瘤与非典型子宫肌瘤是可行的且优于影像组学;基于非增强mp-MRI深度学习特征与临床参数的机器学习模型可获得良好诊断效能。

研究设计与样本

  • 回顾性研究,纳入2011年7月至2019年12月间86例子宫肉瘤和2013年6月至2017年6月间86例非典型子宫肌瘤;从T2WI和DWI提取迁移学习特征与影像组学特征,以随机森林为分类器,分别建立T2、DWI、T2-DWI和复杂多参数模型,以ROC曲线下面积(AUC)评估预测性能。

诊断标准与关键数值

  • 测试集中,基于迁移学习的T2、DWI、T2-DWI和复杂多参数模型AUC分别为0.76~0.81、0.80~0.88、0.85~0.92和0.94~0.96,均优于基于影像组学模型的AUC 0.73、0.76、0.79和0.92;Resnet50复杂多参数模型AUC最高为0.96、准确率为0.87。

临床应用与阅片要点

  • 非增强mp-MRI深度学习特征联合临床参数可用于鉴别子宫肉瘤与非典型子宫肌瘤。
  • 迁移学习特征构建的模型诊断效能优于影像组学特征模型。
  • Resnet50复杂多参数模型在本数据集中预测性能最佳。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: To explore the feasibility and effectiveness of machine learning (ML) based on multiparametric magnetic resonance imaging (mp-MRI) features extracted from transfer learning combined with clinical parameters to differentiate uterine sarcomas from atypical leiomyomas (ALMs).

METHODS: The data of 86 uterine sarcomas between July 2011 and December 2019 and 86 ALMs between June 2013 and June 2017 were retrospectively reviewed. We extracted deep-learning features and radiomics features from T2-weighted imaging (T2WI) and diffusion weighted imaging (DWI). The two feature extraction methods, transfer learning and radiomics, were compared. Random forest was adopted as the classifier. T2WI features, DWI features, combined T2WI and DWI (mp-MRI) features, and combined clinical parameters and mp-MRI features were applied to establish T2, DWI, T2-DWI, and complex multiparameter (mp) models, respectively. Predictive performance was assessed with the area under the receiver operating characteristic curve (AUC).

RESULTS: In the test set, the T2, DWI, T2-DWI and complex mp models based on transfer learning (AUCs range from 0.76 to 0.81, 0.80 to 0.88, 0.85 to 0.92, and 0.94 to 0.96, respectively) outperformed the models based on radiomics (AUCs of 0.73, 0.76, 0.79, and 0.92, respectively). Moreover, the complex mp model showed the best prediction performance, with the Resnet50-complex mp model achieving the highest AUC (0.96) and accuracy (0.87).

CONCLUSIONS: Transfer learning is feasible and superior to radiomics in the differential diagnosis of uterine sarcomas and ALMs in our dataset. ML models based on deep learning features of nonenhanced mp-MRI and clinical parameters can achieve good diagnostic efficacy.

KEY POINTS: • The ML model combining nonenhanced mp-MRI features and clinical parameters can distinguish uterine sarcomas from ALMs. • Transfer learning can be applied to differentiate uterine sarcomas from ALMs and outperform radiomics. • The most accurate prediction model was Resnet50-based transfer learning, built with the deep-learning features of mp-MRI and clinical parameters.

来源:Eur Radiol,查看原文。版权归原作者所有。

引用

  1. Dai, Liu, Hu, et al. Combining multiparametric MRI features-based transfer learning and clinical parameters: application of machine learning for the differentiation of uterine sarcomas from atypical leiomyomas. Eur Radiol. 2022. PMID: 35583712. doi:10.1007/s00330-022-08783-7

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。