文献速递妇产影像泌尿生殖US

O-RADS与ADNEX模型在附件病变恶性率评估和有效性方面的比较

Comparison of the O-RADS and ADNEX models regarding malignancy rate and validity in evaluating adnexal lesions.
PubMed 文献 · Eur Radiol · 2022-05-18

这项回顾性单中心研究纳入322例因附件病变手术的女性,比较O-RADS与ADNEX模型区分良恶性的能力,并由4名额外读者验证快速查阅版O-RADS流程图。O-RADS 2至5类的恶性率分别为0%、3.0%、37.7%和78.9%;在281例中O-RADS、含CA125的ADNEX和不含CA125的ADNEX的AUC分别为0.92、0.95和0.94;以≥10%(≥O-RADS 4)为统一阈值时O-RADS敏感度高于ADNEX(96.6% vs 91.4%),特异度相近。

要点

  • O-RADS 2至5类的恶性率分别为0%、3.0%、37.7%和78.9%。
  • 以≥10%(≥O-RADS 4)为阈值时O-RADS敏感度96.6%,高于ADNEX的91.4%。
  • 快速查阅版O-RADS流程图可能缩短分类分析时间。

核心结论

  • O-RADS对附件病变的良恶性分类与ADNEX模型相当,且在10%阈值下敏感度更高;快速查阅版O-RADS流程图有助于O-RADS分类并可能缩短分析时间。

研究设计与样本

  • 回顾性单中心研究,纳入因附件病变接受手术的女性322例,由2名妇科医生独立按O-RADS和ADNEX模型分类,另纳入4名读者验证快速查阅版O-RADS流程图。

诊断标准与关键数值

  • O-RADS 2、3、4、5类的恶性率分别为0%、3.0%、37.7%、78.9%;322例中O-RADS的AUC为0.93;在其余281例中O-RADS、含CA125的ADNEX和不含CA125的ADNEX的AUC分别为0.92、0.95和0.94;以≥10%(≥O-RADS 4)为统一阈值预测恶性时,O-RADS敏感度96.6% vs ADNEX 91.4%,特异度相对相近。

临床应用与阅片要点

  • 使用快速查阅版O-RADS流程图的读者分类O-RADS所用时间少于仅使用原始O-RADS表格的读者(平均分析时间99分15秒 vs 111分55秒)。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: This study aimed to compare the ability of the O-RADS and ADNEX models to classify benign or malignant adnexal lesions.

METHODS: This retrospective single-center study included women who underwent surgery for adnexal lesions. Two gynecologists independently categorized the adnexal lesions according to the O-RADS and ADNEX models. Four additional readers were included to validate the new quick-access O-RADS flowchart.

RESULTS: Among the 322 patients included in this study, 264 (82.0%) had a benign diagnosis, and 58 (18.0%) had a malignant diagnosis. The malignant rates of O-RADS 2, O-RADS 3, O-RADS 4, and O-RADS 5 were 0%, 3.0%, 37.7%, and 78.9%, respectively. The AUC of the O-RADS in the 322 patients was 0.93. On comparing the O-RADS and ADNEX models in the remaining 281 patients, the AUCs of the O-RADS, ADNEX model with CA125, and ADNEX model without CA125 were 0.92, 0.95, and 0.94, respectively. When setting a uniform cutoff of ≥ 10% (≥ O-RADS 4) to predict malignancy, the O-RADS had higher sensitivity than the ADNEX model (96.6% vs. 91.4%), and relatively similar specificity. In addition, the readers with the quick-access flowchart spent less time categorizing O-RADS than the readers with only the original O-RADS table (mean analysis time: 99 min 15 s vs. 111 min 55 s).

CONCLUSIONS: The O-RADS classification of the adnexal lesions as benign or malignant was comparable to that of the ADNEX model and had higher sensitivity at the 10% cutoff value. A quick-access O-RADS flowchart was helpful in O-RADS categorization and might shorten the analysis time.

KEY POINTS: • Both O-RADS and ADNEX models had good diagnostic performance in distinguishing adnexal malignancy, and O-RADS had higher sensitivity than ADNEX model in uniform 10% cutoff to predict malignancy. • Quick-access O-RADS flowchart was developed to help review O-RADS classification and might help reduce the analysis time.

来源:Eur Radiol,查看原文。版权归原作者所有。

引用

  1. Chen, Hsu, Chan, et al. Comparison of the O-RADS and ADNEX models regarding malignancy rate and validity in evaluating adnexal lesions. Eur Radiol. 2022. PMID: 35583711. doi:10.1007/s00330-022-08803-6

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。