文献速递神经MR

2D常规与合成MRI在多发性硬化评估中的比较

Assessment of 2D conventional and synthetic MRI in multiple sclerosis.
PubMed 文献 · Neuroradiology · 2022-05-18

前瞻性研究纳入27例连续复发缓解型多发性硬化患者,在1.5-T MRI上比较2D常规自旋回波序列与合成序列。常规序列整体图像质量评分占优,而对比度、病灶评估信心及流动伪影方面序列间以一致为主。合成PD与T2-FLAIR图像在多数区域比较中对比噪声比高于对应常规图像,多数区域病灶检出数量无显著差异。

要点

  • 合成MRI在多数脑区检出多发性硬化病灶数量与常规序列无显著差异。
  • 合成PD与T2-FLAIR图像在多数区域比较中对比噪声比高于对应常规图像。
  • 常规序列整体图像质量评分占优,阅片时需注意合成图像质量差异。

核心结论

  • 合成MRI可能作为常规脑MRI序列的替代方法用于多发性硬化评估。

研究设计与样本

  • 前瞻性研究,纳入27例连续复发缓解型多发性硬化患者,在1.5-T MRI扫描仪上采集2D横向常规自旋回波序列(质子密度加权、T2加权、T2-FLAIR、T1加权)及基于2D横向QRAPMASTER与SyMRI软件生成的合成图像,体素大小、重复时间、回波时间及反转时间与常规序列相同;4名评估者进行交叉表定性分析。

关键影像表现/征象

  • 常规序列在整体图像质量评分上占优势。
  • 对比度、病灶评估信心及流动伪影方面序列间以一致为主。
  • 大多数定性参数上所有评估者配对间以不一致为主。

诊断标准与关键数值

  • 定性分析评估整体图像质量、对比度、流动伪影及病灶评估信心,引入优势、一致与不一致概念。
  • 定量分析评估病灶数量(脑室旁、近皮质、脑干、小脑)及区域间对比噪声比(脑脊液、白质、灰质、病灶)。

临床应用与阅片要点

  • 合成MRI可能作为常规脑MRI序列的替代方法用于多发性硬化评估。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: To qualitatively and quantitatively compare synthetic and conventional MRI sequences acquired on a 1.5-T system for patients with multiple sclerosis (MS).

METHODS: Prospective study that involved twenty-seven consecutive relapsing-remitting MS patients scanned on a 1.5-T MRI scanner. The MRI protocol included 2D transverse conventional spin-echo sequences: proton density-weighted (PD), T2-weighted, T2-FLAIR, and T1-weighted. Synthetic images were generated using 2D transverse QRAPMASTER and SyMRI software with the same voxel size, repetition, echo, and inversion times as the conventional sequences. Four raters performed a crosstab qualitative analysis that involved evaluating global image quality, contrast, flow artefacts, and confidence in lesion assessment introducing the concepts of predominance, agreement, and disagreement. A quantitative analysis was also performed and included evaluating the number of lesions (periventricular, juxtacortical, brainstem, and cerebellum) and the contrast-to-noise ratio between regions (CSF, white matter, grey matter, lesions).

RESULTS: The global image quality assessment showed predominance for better scores for conventional sequences over synthetic sequences, whereas contrast, confidence in lesion assessment, and flow artefacts showed predominance for agreement between sequences. There was predominance for disagreement between all pairs of raters in most of the evaluated qualitative parameters. Synthetic PD and T2-FLAIR images showed higher contrast-to-noise ratios than the corresponding conventional images for most comparison between regions. There were no significant differences in the number of lesions detected for most of the study regions between conventional and synthetic images.

CONCLUSION: Synthetic MRI can be potentially used as an alternative to conventional brain MRI sequences in the assessment of MS.

来源:Neuroradiology,查看原文。版权归原作者所有。

引用

  1. Aymerich, Auger, Alonso, et al. Assessment of 2D conventional and synthetic MRI in multiple sclerosis. Neuroradiology. 2022. PMID: 35583667. doi:10.1007/s00234-022-02973-2

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。