文献速递技术与安全腹部胸部CT

应用辐射剂量指数监测软件分析单中心计算机断层扫描剂量数据库:自适应统计迭代重建实施前后的剂量水平与警报

Analysis of a monocentric computed tomography dosimetric database using a radiation dose index monitoring software: dose levels and alerts before and after the implementation of the adaptive statistical iterative reconstruction on CT images.
PubMed 文献 · Radiol Med · 2022-05-17

本研究通过辐射剂量指数监测软件分析单中心4年(2017年1月1日至2020年12月31日)CT剂量数据,评估2018年底实施自适应统计迭代重建(ASIR)前后剂量长度乘积(DLP)的变化及剂量警报情况。结果显示2017-2018年与2019-2020年DLP中位值差异有统计学意义,与ASIR实施相关;最高警报比例出现在「全腹部+胸部+头部」检查组(1.26%至2.14%),警报逐年降低且差异有统计学意义;最高警报比例与错误检查标签/错误检查方案选择相关(29%至40%)。

要点

  • 2017-2018年与2019-2020年DLP中位值差异有统计学意义,与2018年底ASIR技术实施相关。
  • 「全腹部+胸部+头部」检查组警报比例最高,范围为1.26%至2.14%。
  • 警报比例逐年降低且差异有统计学意义,与CT方案优化相关。

核心结论

  • 自动辐射剂量数据收集方法可实现按方案和设备随时间的详细剂量分析;使用CT ASIR技术可能显著降低辐射剂量。

研究设计与样本

  • 单中心剂量数据库分析,使用Qaelum DOSE工具采集2017年1月1日至2020年12月31日4年间64排General Electric Healthcare CT的CT检查剂量数据(包括DLP),并检索触发高辐射剂量(该检查描述中位值的两倍)的警报;两名放射科医生回顾性共识评估图像质量和警报原因;采用卡方检验评估分类变量差异,Kruskal Wallis检验评估连续变量差异。

关键影像表现/征象

  • 2017-2018年与2019-2020年记录的剂量数据间DLP中位值差异有统计学意义,差异与2018年底在CT扫描仪上实施ASIR技术相关。
  • 警报比例最高的CT检查组为「全腹部+胸部+头部」,范围为1.26%至2.14%。
  • 警报比例逐年降低且差异有统计学意义,与CT方案优化相关。
  • 最高警报比例与错误检查标签/错误检查方案选择相关,范围为29%至40%。

诊断标准与关键数值

  • 高辐射剂量警报定义为该检查描述中位值的两倍。

临床应用与阅片要点

  • 使用辐射剂量指数监测软件可按方案和设备随时间详细分析辐射剂量。
  • ASIR技术可能显著降低CT辐射剂量。
  • 错误检查标签/错误检查方案选择是警报的主要原因之一,范围29%至40%。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: To analyze dosimetric data of a single center by a radiation dose index monitoring software evaluating quantitatively the dose reduction obtained with the implementation of the adaptive statistical iterative reconstruction (ASIR) on Computed Tomography in terms of both the value of the dose length product (DLP) and the alerts provided by the dose tool.

METHODS: Dosimetric quantities were acquired using Qaelum DOSE tool (QAELUM NV, Leuven-Heverlee, Belgium). Dose data pertaining to CT examinations were performed using a General Electric Healthcare CT tomography with 64 detectors. CT dose data were collected over 4 years (January 1, 2017 to December 31, 2020) and included CT dose length product (DLP). Moreover, all CT examinations that triggered a high radiation dose (twice the median for that study description), termed alerts on Dose tool, were retrieved for the analysis. Two radiologists retrospectively assessed CT examinations in consensus for the images quality and for the causes of the alerts issued. A Chi-square test was used to assess whether there were any statistically significant differences among categorical variable while a Kruskal Wallis test was considered to assess differences statistically significant for continuous variables.

RESULTS: Differences statistically significant were found for the DLP median values between the dosimetric data recorded on 2017-2018 versus 2019-2020. The differences were linked to the implementation of ASIR technique at the end of 2018 on the CT scanner. The highest percentage of alerts was reported in the CT study group "COMPLETE ABDOMEN + CHEST + HEAD" (range from 1.26% to 2.14%). A reduction year for year was relieved linked to the CT protocol optimization with a difference statistically significant. The highest percentage of alerts was linked to wrong study label/wrong study protocol selection with a range from 29 to 40%.

CONCLUSIONS: Automated methods of radiation dose data collection allowed for detailed radiation dose analysis according to protocol and equipment over time. The use of CT ASIR technique could determine considerable reduction in radiation dose.

来源:Radiol Med,查看原文。版权归原作者所有。

引用

  1. Fusco, Setola, Raiano, et al. Analysis of a monocentric computed tomography dosimetric database using a radiation dose index monitoring software: dose levels and alerts before and after the implementation of the adaptive statistical iterative reconstruction on CT images. Radiol Med. 2022. PMID: 35579854. doi:10.1007/s11547-022-01481-w

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。