断层合成联合合成二维乳腺摄影较单纯数字乳腺摄影提高癌症检出率,在致密乳腺和年轻女性中亦如此:系统综述与Meta分析
该系统综述与Meta分析纳入13项研究,比较数字乳腺断层合成联合合成二维乳腺摄影与单纯数字乳腺摄影的筛查性能。结果显示联合方案在致密乳腺中癌症检出率升高更明显(RR 1.60),非致密乳腺中召回率降低更明显(RR 0.65),双读时癌症检出率升高更明显(RR 1.53),非双读时召回率降低更明显(RR 0.57)。作者指出因纳入Meta分析的研究较少,统计显著性强烈依赖于单个研究结果。
要点
- 致密乳腺中联合方案癌症检出率RR 1.60(95%CI 1.16-2.22),高于非致密乳腺的RR 1.32(95%CI 1.08-1.61)。
- 非致密乳腺召回率RR 0.65(95%CI 0.59-0.72),致密乳腺召回率RR 0.84(95%CI 0.75-0.94)。
- 双读时癌症检出率RR 1.53(95%CI 1.40-1.67),非双读时召回率RR 0.57(95%CI 0.54-0.60)。
核心结论
- 联合方案较单纯数字乳腺摄影提高癌症检出率,致密乳腺中升高更明显,双读时癌症检出率升高更明显,非双读时召回率降低更明显;因纳入Meta分析的研究较少,统计显著性强烈依赖单个研究结果。
研究设计与样本
- 系统综述与Meta分析,检索PubMed和Cochrane library,纳入13项比较数字乳腺断层合成联合合成二维乳腺摄影与单纯数字乳腺摄影的研究,采用固定或随机效应模型计算 pooled 风险比,使用QUADAS-2工具评估偏倚风险。
诊断标准与关键数值
- 致密乳腺癌症检出率:纳入3项研究,固定效应模型RR 1.60(95%CI 1.16-2.22)。
- 非致密乳腺癌症检出率:纳入3项研究,固定效应模型RR 1.32(95%CI 1.08-1.61)。
- 致密乳腺召回率:纳入2项研究,RR 0.84(95%CI 0.75-0.94)。
- 非致密乳腺召回率:纳入2项研究,RR 0.65(95%CI 0.59-0.72)。
- 年龄<60岁癌症检出率RR 1.64(95%CI 1.18-2.29,n=2),≥60岁RR 1.56(95%CI 1.19-2.05,n=2)。
临床应用与阅片要点
- 原文未据此给出推荐。
局限性
- 原文指出仅少数研究可用于Meta分析,统计显著性强烈依赖于单个研究结果。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVES: This systematic review and meta-analysis focuses on breast cancer screening performance outcomes stratified into breast density, age, and reading procedure using 'digital breast tomosynthesis (DBT) with synthesised two-dimensional mammography (s2D)' compared to 'digital mammography (DM) alone'.
METHODS: Studies comparing 'DBT with s2D' and 'DM' were searched in PubMed and Cochrane library. Pooled risk ratios (RR) using fixed or random effects models (F-/REM) for cancer detection rates (CDR), recall rates, interval cancer rates (ICR), biopsy rates, and positive predictive values (PPV) 1-3 were calculated. Outcomes were stratified into breast density (non-dense and dense), age (<60, ≥60), and reading procedure (double-/non-double reading). Risk of bias was assessed using the Quality Assessment of Diagnostic Accuracy Studies (QUADAS)-2 tool.
RESULTS: We identified 13 studies. Using DBT plus s2D compared to DM alone resulted in a higher increase in CDR for dense ([number of studies included, FEM RR, 95% confidence interval (CI)]; n = 3, 1.60, 1.16-2.22) versus non-dense breasts (n = 3, 1.32, 1.08-1.61). Recall rates were lower in dense (n = 2, 0.84, 0.75-0.94), but much lower for non-dense breasts (n = 2, 0.65, 0.59-0.72). Age stratification resulted in small differences in CDR (<60: n = 2, 1.64, 1.18-2.29 / ≥60: n = 2, 1.56, 1.19-2.05). After screening with DBT plus s2D compared to DM alone the risk of being recalled was less in non-double (n = 3, 0.57, 0.54-0.60) than in double reading (n = 5, 0.95, 0.81-1.11) and the risk of cancer detection was higher in double reading (n = 6, 1.53, 1.40-1.67) than in non-double reading (n = 4, 1.17, 1.02-1.33).
CONCLUSION: Since only few studies are available for meta-analyses statistical significance strongly depends on single study results. Taking this into account, the most important results concern the increase of CDR in women with dense breasts, the increased CDR in double reading, and the lower recall rates particularly with non-double reading.
引用
- Heywang-Köbrunner, Jänsch, Hacker, et al. Tomosynthesis with synthesised two-dimensional mammography yields higher cancer detection compared to digital mammography alone, also in dense breasts and in younger women: A systematic review and meta-analysis. Eur J Radiol. 2022. PMID: 35576720. doi:10.1016/j.ejrad.2022.110324
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。