文献速递腹部泌尿生殖MR

同一病灶上不同表观扩散系数测量方法在肾细胞癌中的应用及其与ISUP核分级的相关性

Application of different methods used to measure the apparent diffusion coefficient of renal cell carcinoma on the same lesion and its correlation with ISUP nuclear grading.
PubMed 文献 · Abdom Radiol (NY) · 2022-05-16

研究纳入99例经病理确诊的肾细胞癌患者,在 diffusion-weighted imaging 上采用五种ROI选择与测量方法测定ADC值并与ISUP核分级对照。结果显示各方法测得肾细胞癌ADC值均显著低于正常肾实质,pRCC与chRCC的ADC值低于ccRCC;ADC1和ADC5与ISUP核分级呈最强负相关,其中ADC5在低级别与高级别组间差异有统计学意义(p=0.046)。作者认为ADC5与ISUP组织学分级相关性最佳,可作为确定肾细胞癌ADC值的首选测量方法。

要点

  • 五种ADC测量方法中,ADC1与ADC5和ISUP核分级的相关性最强。
  • ADC5测量在ISUP低级别与高级别组间差异有统计学意义(p=0.046)。
  • 各测量方法下pRCC与chRCC的ADC值均低于ccRCC。

核心结论

  • ADC5是与ISUP组织学分级相关性最佳的测量方法,作者认为ADC5可作为确定肾细胞癌ADC值的首选测量方法。

研究设计与样本

  • 共纳入99例接受扩散加权成像且病理确诊为肾细胞癌的患者;经文献回顾确定五种ROI选择与测量方法(ADC1至ADC5),并从对侧正常肾实质进行ADC测量;肿瘤病理分为71例透明细胞肾细胞癌、17例嫌色细胞肾细胞癌、11例乳头状肾细胞癌,按ISUP核分级系统分为42例高级别与57例低级别。

诊断标准与关键数值

  • 所有测量方法中肾细胞癌ADC值均低于正常肾脏ADC值;ADC3与ADC4测量值之间无差异(p=0.999),其他测量方法间差异有统计学意义(p<0.001);所有测量方法下pRCC与chRCC的ADC值均低于ccRCC;所有ADC测量值与ISUP核分级呈负相关,ADC1与ADC5相关性最强;ISUP低级别与高级别组比较中仅ADC5测量方法差异有统计学意义(p=0.046)。

临床应用与阅片要点

  • 作者认为ADC5可作为确定肾细胞癌ADC值的主要测量方法,日常测量时应优先关注在病灶实性最受限部分放置三个小ROI的方式。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: To determine the most frequently used different apparent diffusion coefficient (ADC) measurement methods in renal cell carcinoma (RCC), and their correlation with the International Society of Urological Pathology (ISUP) histologic grading system.

METHODS: A total of 99 patients who underwent diffusion-weighted imaging and whose pathologic diagnosis of RCC was confirmed were included in the study. As a result of a literature review, region of interest (ROI) selection and measurement methods were determined in five ways. These included a small ROI (ADC1) on the solid part of the lesion showing the most restriction; a large ROI (ADC2) on the solid part of the lesion showing restriction; ROI (ADC3) that covered the lesion in the cross-section with the largest diameter, which was obtained by placing ROIs (ADC4) covering the lesion on all sections of the lesion; three small ROIs (ADC5) on solid parts of the lesion showing the most restriction. Then, ADC measurements were made from the contralateral normal kidney parenchyma. Tumors were pathologically subdivided [71 clear cell RCCs (ccRCC), 17 chromophobe RCCs (chRCC), 11 papillary RCCs (pRCC)], and graded according to the ISUP nuclear grading system (42 high-grade, 57 low-grade). Data were analyzed statistically.

RESULTS: In all measurement methods, ADC values of RCCs were statistically significantly lower than normal kidney ADC values. There were no differences between the ADC3 and ADC4 measurements of RCCs (p = 0.999). There was a statistical difference in other measurement methods (p < 0.001). There were differences between ccRCCs and pRCCs and chRCCs in all measurement methods. In all measurement methods, pRCC and chRCC ADC values were lower than ccRCC ADC values. When ISUP nuclear grading and ADC values were compared, there was a statistically inverse correlation between all ADC measurements. The strongest correlation was found in the ADC1 and ADC5 measurements. When the ADC values of ISUP low and high-grade groups were compared, a significant difference was found in the ADC5 measurement method (p = 0.046).

CONCLUSION: According to the findings of the study, ADC5 is the measurement method that shows the best correlation with the ISUP histologic grading system. Therefore, we think that ADC5 can be the primary measurement method for determining the ADC value of RCCs.

来源:Abdom Radiol (NY),查看原文。版权归原作者所有。

引用

  1. Kılıçarslan, Eroğlu, Kılıçarslan, et al. Application of different methods used to measure the apparent diffusion coefficient of renal cell carcinoma on the same lesion and its correlation with ISUP nuclear grading. Abdom Radiol (NY). 2022. PMID: 35570223. doi:10.1007/s00261-022-03541-1

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。