新生儿先天性膈疝的定量心肺磁共振成像
前瞻性纳入23例新生儿(左侧孤立性CDH:4例修复前、7例修复后、3例修复前后均扫描;9例对照),用小Footprint 1.5T扫描仪行MRI定量肺动脉血流、左心室偏心指数、心功能及肺体积。修复前和修复后CDH的右左肺动脉血流比及肺体积比均高于对照;收缩末期偏心指数在修复前与修复后CDH之间及修复前CDH与对照之间差异有统计学意义。作者认为心肺MRI是系列评估危重婴儿心肺血流动力学与功能的可行方法。
要点
- 修复前和修复后CDH新生儿的右左肺动脉血流比和肺体积比均高于对照。
- 收缩末期左心室偏心指数在修复前与修复后CDH间及修复前CDH与对照间有显著差异。
- 小Footprint 1.5T扫描仪可行新生儿CDH心肺MRI定量评估。
核心结论
- 心肺MRI是系列评估危重婴儿心肺血流动力学与功能的可行方法,可用于捕捉肺动脉血流和肺体积的左右不对称。
研究设计与样本
- 前瞻性MRI研究,纳入23例新生儿,包括左侧孤立性CDH 4例修复前、7例修复后、3例修复前后均扫描,以及9例对照,使用小Footprint 1.5T扫描仪。
诊断标准与关键数值
- 修复前CDH与对照相比右左肺动脉血流比升高,P<0.005。
- 修复前和修复后CDH与对照相比右左肺体积比升高,修复前P<0.05、修复后P<0.05。
- 收缩末期偏心指数在修复前CDH与修复后CDH之间差异有统计学意义,P<0.01。
- 收缩末期偏心指数在修复前CDH与对照之间差异有统计学意义,P<0.001。
临床应用与阅片要点
- 作者认为心肺MRI可用于系列评估危重婴儿的心肺血流动力学与功能。
- 作者认为心肺MRI有助于捕捉肺动脉血流和肺体积的左右不对称。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
BACKGROUND: Pulmonary arterial hypertension, impaired cardiac function and lung hypoplasia are common in infants with congenital diaphragmatic hernia (CDH) and are associated with increased morbidity and mortality. Robust noninvasive methods to quantify these abnormalities in early infancy are lacking.
OBJECTIVE: To determine the feasibility of MRI to quantify cardiopulmonary hemodynamics and function in infants with CDH and to investigate left-right blood flow and lung volume discrepancies.
MATERIALS AND METHODS: We conducted a prospective MRI study of 23 neonates (isolated left CDH: 4 pre-repair, 7 post-repair, 3 pre- and post-repair; and 9 controls) performed on a small-footprint 1.5-tesla (T) scanner. We calculated MRI-based pulmonary arterial blood flow, left ventricular eccentricity index, cardiac function and lung volume. Using the Wilcoxon rank sum test for continuous data and Fisher exact test for categorical data, we made pairwise group comparisons.
RESULTS: The right-to-left ratios for pulmonary artery blood flow and lung volume were elevated in pre-repair and post-repair CDH versus controls (flow: P<0.005; volume: P<0.05 pre-/post-repair). Eccentricity index at end-systole significantly differed between pre-repair and post-repair CDH (P<0.01) and between pre-repair CDH and controls (P<0.001).
CONCLUSION: Cardiopulmonary MRI is a viable method to serially evaluate cardiopulmonary hemodynamics and function in critically ill infants and is useful for capturing left-right asymmetries in pulmonary blood flow and lung volume.
引用
- Tkach, Higano, Taylor, et al. Quantitative cardiopulmonary magnetic resonance imaging in neonatal congenital diaphragmatic hernia. Pediatr Radiol. 2022. PMID: 35556152. doi:10.1007/s00247-022-05384-w
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。