文献速递胸部CT

计算机辅助实性成分测量提高亚实性结节类型及 Lung-RADS 分类的观察者间一致性

Improved interobserver agreement on nodule type and Lung-RADS classification of subsolid nodules using computer-aided solid component measurement.
PubMed 文献 · Eur J Radiol · 2022-05-05

本研究纳入 121 例患者共 156 个亚实性结节,由 3 名独立阅片者分别在不使用和使用半自动计算机辅助工具的情况下判定结节类型、测量整个结节及实性成分大小并给出 Lung-RADS 1.1 分类。半自动评估的结节类型(κ=0.974)和 Lung-RADS 分类(直径 κ=0.958、体积 κ=0.952)观察者间一致性均高于手动评估(结节类型 κ=0.783、Lung-RADS 分类 κ=0.652),且在 26 个病理证实的浸润性腺癌中识别出更多 4B 类结节。

要点

  • 半自动测量实性成分可提高结节类型判定的观察者间一致性(κ 0.974 vs 手动 0.783)。
  • 半自动评估 Lung-RADS 分类一致性更高(直径 κ=0.958、体积 κ=0.952 vs 手动 κ=0.652)。
  • 半自动评估倾向于将病理证实的浸润性腺癌归入更高风险类别(4B 类更多)。

核心结论

  • 半自动评估可提高亚实性结节类型和 Lung-RADS 分类的观察者间一致性,并倾向于将对应病理证实的浸润性腺癌的亚实性结节归入更高风险类别。

研究设计与样本

  • 研究纳入 121 例患者共 156 个亚实性结节,均为接受肺癌初筛 CT 者;3 名独立阅片者先手动、后借助半自动计算机辅助工具判定结节类型、测量整个结节及实性成分大小并给出 Lung-RADS 1.1 分类;以病理诊断评估最终诊断与 Lung-RADS 分类的关系。

诊断标准与关键数值

  • 手动测量结节大小 ICC 为 0.994;48 个结节含实性成分且 3 名阅片者均完成手动与半自动测量,实性成分测量 ICC 手动直径为 0.952、半自动直径为 0.997、半自动体积为 0.996。

临床应用与阅片要点

  • 半自动测量实性成分的平均直径偏差及 95% 一致性界限均小于手动测量;半自动评估结节类型 κ=0.974,Lung-RADS 分类直径 κ=0.958、体积 κ=0.952,均高于手动评估的结节类型 κ=0.783 和 Lung-RADS 分类 κ=0.652;在 26 个病理证实的浸润性腺癌中,半自动评估较手动识别出更多 4B 类结节。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: The Lung CT Screening Reporting and Data System (Lung-RADS) classification of subsolid nodules (SSNs) can be challenging due to limited interobserver agreement in determining the type and size of the nodule. Our study aimed to assess the effect of a computer-aided method on the interobserver agreement of Lung-RADS classification for SSNs.

MATERIALS AND METHODS: This study consisted of 156 SSNs in 121 patients who underwent initial CT screening for lung cancer. Three independent readers determined the nodule type and measured the size of the entire nodule as well as the solid component, first without and then assisted by a semi-automated computer-aided tool. They assigned to each nodule the corresponding Lung-RADS 1.1 category. Agreement in size measurements was assessed by intraclass correlation coefficient (ICC) and Bland-Altman indexes, while agreement in nodule type and Lung-RADS was determined using Fleiss kappa statistics. The relationship between final diagnosis of the nodules and Lung-RADS classifications was also evaluated.

RESULTS: Among the 156 nodules, manual size measurement reached an ICC of 0.994, and 48 nodules contained solid component measured by all the three readers both manually and semi-automatically. ICCs for the solid component measurement were 0.952, 0.997 and 0.996 for manual diameter, semi- automated diameter and volume measurement, respectively. Bias and 95% limits of agreement for average diameter of solid component were smaller with semi-automated measurements than with manual measurements. Kappa values of semi-automated assessment for nodule type (0.974) and Lung-RADS classification (0.958 for diameter and 0.952 for volume) were higher than with the manual measurements (0.783 for nodule type and 0.652 for Lung-RADS classification). Compared to manual work, the semi-automated assessment identified more 4B nodules among the 26 pathologically confirmed invasive adenocarcinomas (IACs).

CONCLUSION: Semi-automated assessment could improve the interobserver agreement of nodule type and Lung-RADS classification for SSNs, and be inclined to classify SSNs corresponding to pathologically confirmed IACs into higher risk categories.

来源:Eur J Radiol,查看原文。版权归原作者所有。

引用

  1. Shu, Wen, Xu, et al. Improved interobserver agreement on nodule type and Lung-RADS classification of subsolid nodules using computer-aided solid component measurement. Eur J Radiol. 2022. PMID: 35537358. doi:10.1016/j.ejrad.2022.110339

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。