低剂量胸部CT使用深度学习图像重建对肺气肿定量的影响
回顾性分析54例COPD患者低剂量胸部CT,原始数据分别以FBP、ASIR-V 70%及DLIR-H/M/L重建,滤波FBP为参考。各重建间肺气肿体积差异显著(p<10⁻³),DLIR-H与滤波FBP相关性最强(r=0.999)但高估约10%,且噪声最低、SNR最高。
要点
- DLIR-H与滤波FBP测得的肺气肿体积相关性最强(r=0.999),但存在约10%的高估。
- FBP、ASIR-V与DLIR各强度间肺气肿体积差异均有统计学意义(p<10⁻³)。
- DLIR-H较其他重建方法噪声显著降低,SNR显著提高(p<10⁻⁶)。
核心结论
- FBP、迭代重建与深度学习DLIR算法测得的肺气肿体积存在显著差异,DLIR-H与滤波FBP相关性最接近且提高SNR。
研究设计与样本
- 回顾性研究,纳入54例慢性阻塞性肺疾病(COPD)患者低剂量胸部CT,原始数据以FBP、ASIR-V 70%及DLIR-H、DLIR-M、DLIR-L重建,滤波FBP图像为参考标准。
关键影像表现/征象
- 肺气肿体积以体素值低于-950 UH的比例定量测量,并由一名胸部放射科医生视觉评估。
- 于气管、空气及椎旁肌肉放置3个感兴趣区评估定量图像质量并测量信噪比。
诊断标准与关键数值
- 肺气肿体积定义为CT值低于-950 UH的体素比例。
- 滤波FBP参考与ASIR-V、DLIR-H、DLIR-M或DLIR-L之间肺气肿体积差异均有统计学意义(p<10⁻³)。
- 滤波FBP与DLIR-H肺气肿体积强相关(r=0.999,p<10⁻⁴),DLIR-H高估约10%。
临床应用与阅片要点
- DLIR-H与滤波FBP相关性最强且噪声显著降低、SNR提高(p<10⁻⁶),但报告肺气肿定量时需注意其约10%的高估。
- 不同重建算法间肺气肿体积存在显著差异,阅片及定量随访时应注明所用重建方法。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
PURPOSE: Quantitative analysis of emphysema volume is affected by the radiation dose and the CT reconstruction technique. We aim to evaluate the influence of a commercially available deep learning image reconstruction algorithm (DLIR) on the quantification of pulmonary emphysema in low-dose chest CT.
METHODS: We performed a retrospective study of low dose chest CT scans in 54 patients with chronic obstructive pulmonary disease (COPD). Raw data were reconstructed using FBP, iterative reconstruction (ASIR-V 70%) and deep learning based algorithms at high, medium and low-strength (DLIR -H, -M, -L). Filtered FBP images served as reference. Pulmonary emphysema volume (proportion of voxels below -950 UH) was measured on each reconstruction dataset and visually assessed by a chest radiologist. Quantitative image quality was assessed by placing 3 regions of interest in the trachea, in air and in a paraspinal muscle. Signal to noise ratio was also measured.
RESULTS: The mean CDTIvol was 2.38 ± 0.68 mGy. Significant differences in emphysema volumes between the filtered FBP reference and ASIR-V, DLIR-H, DLIR-M or DLIR-L were observed, (p < 10-3) for all. A strong correlation between filtered FBP volumes and DLIR-H was reported (r = 0.999, p < 10-4), a 10% overestimation with DLIR-H being observed. Noise was significantly reduced in DLIR-H volumes compared to the other reconstruction methods. Signal to noise ratio was improved when using DLIR-H (p < 10-6).
CONCLUSION: There are significant differences regarding emphysema volumes between FBP, iterative reconstruction or deep learning-based DLIR algorithm. DLIR-H shows the closest correlation to filtered FBP while increasing SNR.
引用
- Ferri, Bouzerar, Auquier, et al. Pulmonary emphysema quantification at low dose chest CT using Deep Learning image reconstruction. Eur J Radiol. 2022. PMID: 35533559. doi:10.1016/j.ejrad.2022.110338
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。