优化肺部超声:深度、增益和焦点位置对超声B线的影响
前瞻性研究评估凸阵与线阵探头、深度、增益及焦点位置对B线显示和图像质量的影响,共分析516段视频。凸阵探头B线显示率更高(63% vs 37%,p<0.0001)且图像质量更优(3.52±0.71 vs 3.31±0.86,p=0.0047);B线在高增益和焦点位于胸膜线时显示更好,图像质量在增益50%、深度12–18 cm时最高。
要点
- 凸阵探头较线阵探头提高B线显示率(63% vs 37%)和图像质量(3.52±0.71 vs 3.31±0.86)。
- 增益50%和90%较10%均改善B线显示(OR=7.04和OR=9.48),焦点位于胸膜线亦改善显示(OR=1.64)。
- 图像质量在增益50%时最高,深度12–18 cm时最高,增益90%或焦点位于胸膜线时图像质量下降。
核心结论
- 使用凸阵探头、增益至少50%且焦点位于胸膜线时B线显示最佳;增益低于90%和图像深度12–18 cm可提高图像质量。
研究设计与样本
- 前瞻性研究,共获取并分析516段视频片段,在单一肋间隙使用凸阵和线阵探头,改变深度、增益和焦点位置采集。
关键影像表现/征象
- 凸阵探头较线阵探头B线显示率更高(63% vs 37%,p<0.0001),图像质量评分更高(3.52±0.71 vs 3.31±0.86,p=0.0047)。
- 增益50%较10%改善B线显示(OR=7.04,95%CI 4.03–12.3),增益90%较10%改善B线显示(OR=9.48,95%CI 5.28–17.0)。
- 焦点位于胸膜线较其他位置改善B线显示(OR=1.64,95%CI 1.02–2.63)。
- 图像质量在增益50%时最高(p=0.02),增益90%时下降(p<0.0001),焦点位于胸膜线时下降(p<0.0001)。
- 图像质量在深度12–18 cm时最高。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
Ultrasonographic B-lines are artifacts present in alveolar-interstitial syndromes. We prospectively investigated optimal depth, gain, focal position and transducer type for B-line visualization and image quality. B-Lines were assessed at a single rib interspace with curvilinear and linear transducers. Video clips were acquired by changing parameters: depth (6, 12, 18 and 24 cm for curvilinear transducer, 4 and 8 cm for linear transducer), gain (10%, 50% and 90%) and focal position (at the pleural line or half the scanning depth). Clips were scored for B-lines and image quality. Five hundred sixteen clips were obtained and analyzed. The curvilinear transducer improved B-line visualization (63% vs. 37%, p < 0.0001), with higher image quality (3.52 ± 0.71 vs. 3.31 ± 0.86, p = 0.0047) compared with the linear transducer. B-Lines were better visualized at higher gains (curvilinear: gain of 50% vs. 10%, odds ratio = 7.04, 95% confidence interval: 4.03-12.3; gain of 90% vs. 10%, odds ratio = 9.48, 95% confidence interval: 5.28-17.0) and with the focal point at the pleural line (odds ratio = 1.64, 95% confidence interval: 1.02-2.63). Image quality was highest at 50% gain (p = 0.02) but decreased at 90% gain (p < 0.0001) and with the focal point at the pleural line (p < 0.0001). Image quality was highest at depths of 12-18 cm. B-Lines are best visualized using a curvilinear transducer with at least 50% gain and focal position at the pleural line. Gain less than 90% and image depth between 12 and 18 cm improve image quality.
引用
- Duggan, Goldsmith, Saud, et al. Optimizing Lung Ultrasound: The Effect of Depth, Gain and Focal Position on Sonographic B-Lines. Ultrasound Med Biol. 2022. PMID: 35527112. doi:10.1016/j.ultrasmedbio.2022.03.015
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。