文献速递心血管儿科影像MR

儿童人群中压缩感知心脏电影成像与标准平衡稳态自由进动电影成像的比较

Compressed Sensing Cardiac Cine Imaging Compared with Standard Balanced Steady-State Free Precession Cine Imaging in a Pediatric Population.
PubMed 文献 · Radiol Cardiothorac Imaging · 2022-04-21

前瞻性纳入20例儿童(平均年龄15岁±5,范围7-21岁,10例男性),分别用1.5-T设备行bSSFP和CS序列检查,比较心室容积与功能测量。读者1两种序列间各参数无显著差异(P>.05),读者2仅射血分数有显著差异(P=.02);CS平均采集时间20秒(范围17-25秒)短于bSSFP的160秒(范围130-190秒)(P<.001)。结论认为CS提供与bSSFP等效的心室容积和功能测量且采集时间更短,可能适用于儿童人群。

要点

  • CS与bSSFP的心室容积和功能测量在读者1各参数无显著差异(P>.05)。
  • 读者2仅射血分数在两种序列间有显著差异(P=.02)。
  • CS平均采集时间20秒(17-25秒)短于bSSFP 160秒(130-190秒)(P<.001)。

核心结论

  • CS心脏电影成像提供与bSSFP等效的心室容积和功能测量,且采集时间更短,可能适用于儿童人群。

研究设计与样本

  • 前瞻性研究纳入20例儿童(平均年龄15岁±5,范围7-21岁,10例男性),双心室先天性心脏病11例或心肌病9例,使用1.5-T设备对所有参与者行bSSFP和CS序列检查;由两名对患者诊断和序列类型设盲的读者行心室容积和功能定量,并与一名读者的相位对比血流测量做相关分析,分析读者内和读者间一致性。

诊断标准与关键数值

  • 读者1:CS与bSSFP测得的心室参数无显著差异(P>.05)。
  • 读者2:仅射血分数在两种序列间有显著差异(P=.02)。
  • 读者内一致性:bSSFP平均差值范围+1至-2.6,最大CI +7.9、-13,偏倚范围0.1%-4.1%,ICC范围0.931-0.997;CS平均差值范围+7.4至-5.6,最大CI +37.2、-48.8,偏倚范围0.5%-7.5%,ICC范围0.717-0.997。
  • 读者间一致性:bSSFP平均差值范围+2.6至-5.6,最大CI +60.7、-65.3,偏倚范围1.6%-6.2%,ICC范围0.726-0.951;CS平均差值范围+10.7至-9.1,最大CI +87.5、-84.6,偏倚范围1.1%-17.3%,ICC范围0.509-0.849。
  • CS平均采集时间20秒(范围17-25秒)vs bSSFP平均采集时间160秒(范围130-190秒),CS更短(P<.001)。

局限性

  • 读者间一致性可接受但不甚稳健,尤其是CS(bSSFP ICC范围0.726-0.951;CS ICC范围0.509-0.849)。
  • 结论用「可能适用」(may prove suitable)表述,未做确定性推荐。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: To compare real-time compressed sensing (CS) and standard balanced steady-state free precession (bSSFP) cardiac cine imaging in children.

MATERIALS AND METHODS: Twenty children (mean age, 15 years ± 5 [SD], range, 7-21 years; 10 male participants) with biventricular congenital heart disease (n = 11) or cardiomyopathy (n = 9) were prospectively included. Examinations were performed with 1.5-T imagers by using both bSSFP and CS sequences in all participants. Quantification of ventricular volumes and function was performed for all images by two readers blinded to patient diagnosis and type of sequence. Values were correlated with phase-contrast flow measurements by one reader. Intra- and interreader agreement were analyzed.

RESULTS: There were no significant differences between ventricular parameters measured on CS compared with those of bSSFP (P > .05) for reader 1. Only ejection fraction showed a significant difference (P = .02) for reader 2. Intrareader agreement was considerable for both sequences (bSSFP: mean difference range, +1 to -2.6; maximum CI, +7.9, -13; bias range, 0.1%-4.1%; intraclass correlation coefficient [ICC] range, 0.931-0.997. CS: mean difference range, +7.4 to -5.6; maximum CI, +37.2, -48.8; bias range, 0.5%-7.5%; ICC range, 0.717-0.997). Interreader agreement was acceptable but less robust, especially for CS (bSSFP: mean difference range, +2.6 to -5.6; maximum CI, +60.7, -65.3; bias range, 1.6%-6.2%; ICC range, 0.726-0.951. CS: mean difference range, +10.7 to -9.1; maximum CI, +87.5, -84.6; bias range, 1.1%-17.3%; ICC range, 0.509-0.849). The mean acquisition time was shorter for CS (20 seconds; range, 17-25 seconds) compared with that for bSSFP (160 seconds; range, 130-190 seconds) (P < .001).

CONCLUSION: CS cardiac cine imaging provided equivalent ventricular volume and function measurements with shorter acquisition times compared with those of bSSFP and may prove suitable for the pediatric population.Keywords: Compressed Sensing, Balanced Steady-State Free Precession, Cine Imaging, Cardiovascular MRI, Pediatrics, Cardiac, Heart, Cardiomyopathies, Congenital, Segmentation© RSNA, 2022.

来源:Radiol Cardiothorac Imaging,查看原文。版权归原作者所有。

引用

  1. Curione, Ciliberti, Monti, et al. Compressed Sensing Cardiac Cine Imaging Compared with Standard Balanced Steady-State Free Precession Cine Imaging in a Pediatric Population. Radiol Cardiothorac Imaging. 2022. PMID: 35506130. doi:10.1148/ryct.210109

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。